134738-Thumbnail Image.png
Description
Recent research has confirmed and revealed many physical and mental benefits of yoga. The practice of yoga has spread throughout the western world, where it is widely used for the purpose of exercise and fitness. Due to its rise in

Recent research has confirmed and revealed many physical and mental benefits of yoga. The practice of yoga has spread throughout the western world, where it is widely used for the purpose of exercise and fitness. Due to its rise in popularity, there is a need for research regarding the energy expenditure required for different types of yoga. The majority of the literature cites yoga as being an effective exercise for light intensity activity, but there are not as many studies attempting to determine if there are postures and sequences that can meet the requirements for moderate physical activity. In addition, there is a need to validate mobile devices with which to measure energy expenditure (EE) that are compatible with the dynamic movements that occur during yoga. The purpose of this study was to measure energy expenditure of twenty-two yoga practitioners of varying experience during a 30-minute Vinyasa flow yoga practice and from this data collection determine: if an ashtanga-based vinyasa yoga class meets the criteria for moderate intensity physical activity, the reliability between the Actigraph and Oxycon Mobile and the validity of an Actigraph GT3X device worn on the hip in estimating energy expenditure for ashtanga-based vinyasa flow yoga. The Actigraph GT3X and the Oxycon mobile were used to measure energy expenditure. Mean values for energy expenditure recorded by the Oxycon and Actigraph were 3.19 ± 0.42 METs and 1.16 ± 0.23 METs respectively, exhibiting a significant difference in data collection. There was no correlation between the values recorded by the two devices, indicating that the Actigraph was not consistent with the Oxycon Mobile (previously validated for measurement of EE). Results of this study indicate that this Vinyasa flow yoga sequence does satisfy the criteria for moderate intensity physical activity as defined by ACSM with an average EE of 3.19 ± 0.42 METs, and that the Actigraph GT3X is not an accurate device for measurement of EE for yoga.
296.33 KB application/pdf

Download restricted. Please sign in.
Restrictions Statement

Barrett Honors College theses and creative projects are restricted to ASU community members.

Details

Title
  • Measurement of Energy Expenditure During Fast-Paced Vinyasa Flow Yoga
Contributors
Date Created
2016-12
Resource Type
  • Text
  • Machine-readable links