Matching Items (139)
152192-Thumbnail Image.png
Description
ABSTRACT Peptide microarrays may prove to be a powerful tool for proteomics research and clinical diagnosis applications. Fodor et al. and Maurer et al. have shown proof-of-concept methods of light- and electrochemically-directed peptide microarray fabrication on glass and semiconductor microchips respectively. In this work, peptide microarray fabrication based on the

ABSTRACT Peptide microarrays may prove to be a powerful tool for proteomics research and clinical diagnosis applications. Fodor et al. and Maurer et al. have shown proof-of-concept methods of light- and electrochemically-directed peptide microarray fabrication on glass and semiconductor microchips respectively. In this work, peptide microarray fabrication based on the abovementioned techniques were optimized. In addition, MALDI mass spectrometry based peptide synthesis characterization on semiconductor microchips was developed and novel applications of a CombiMatrix (CBMX) platform for electrochemically controlled synthesis were explored. We have investigated performance of 2-(2-nitrophenyl)propoxycarbonyl (NPPOC) derivatives as photo-labile protecting group. Specifically, influence of substituents on 4 and 5 positions of phenyl ring of NPPOC group on the rate of photolysis and the yield of the amine was investigated. The results indicated that substituents capable of forming a π-network with the nitro group enhanced the rate of photolysis and yield. Once such properly substituted NPPOC groups were used, the rate of photolysis/yield depended on the nature of protected amino group indicating that a different chemical step during the photo-cleavage process became the rate limiting step. We also focused on electrochemically-directed parallel synthesis of high-density peptide microarrays using the CBMX technology referred to above which uses electrochemically generated acids to perform patterned chemistry. Several issues related to peptide synthesis on the CBMX platform were studied and optimized, with emphasis placed on the reactions of electro-generated acids during the deprotection step of peptide synthesis. We have developed a MALDI mass spectrometry based method to determine the chemical composition of microarray synthesis, directly on the feature. This method utilizes non-diffusional chemical cleavage from the surface, thereby making the chemical characterization of high-density microarray features simple, accurate, and amenable to high-throughput. CBMX Corp. has developed a microarray reader which is based on electro-chemical detection of redox chemical species. Several parameters of the instrument were studied and optimized and novel redox applications of peptide microarrays on CBMX platform were also investigated using the instrument. These include (i) a search of metal binding catalytic peptides to reduce overpotential associated with water oxidation reaction and (ii) an immobilization of peptide microarrays using electro-polymerized polypyrrole.
ContributorsKumar, Pallav (Author) / Woodbury, Neal (Thesis advisor) / Allen, James (Committee member) / Johnston, Stephen (Committee member) / Arizona State University (Publisher)
Created2013
168649-Thumbnail Image.png
Description
The imaging and detection of specific cell types deep in biological tissue is critical for the diagnosis of cancer and the study of biological phenomena. Current high-resolution optical imaging techniques are depth limited due to the high degree of optical scattering that occurs in tissues. To address these limitations, photoacoustic

The imaging and detection of specific cell types deep in biological tissue is critical for the diagnosis of cancer and the study of biological phenomena. Current high-resolution optical imaging techniques are depth limited due to the high degree of optical scattering that occurs in tissues. To address these limitations, photoacoustic (PA) techniques have emerged as noninvasive methods for the imaging and detection of specific biological structures at extended depths in vivo. In addition, near-infrared (NIR) contrast agents have further increased the depth at which PA imaging can be achieved in biological tissues. The goal of this research is to combine novel PA imaging and NIR labeling strategies for the diagnosis of disease and for the detection of neuronal subtypes. Central Hypothesis: Utilizing custom-designed PA systems and NIR labeling techniques will enable the detection of specific cell types in vitro and in mammalian brain slices. Work presented in this dissertation addresses the following: (Chapter 2): The custom photoacoustic flow cytometry system combined with NIR absorbing copper sulfide nanoparticles for the detection of ovarian circulating tumor cells (CTCs) at physiologically relevant concentrations. Results obtained from this Chapter provide a unique tool for the future detection of ovarian CTCs in patient samples at the point of care. (Chapter 3): The custom photoacoustic microscopy (PAM) system can detect genetically encoded near-infrared fluorescent proteins (iRFPs) in cells in vitro. Results obtained from this Chapter can significantly increase the depth at which neurons and cellular processes can be targeted and imaged in vitro. (Chapter 4): Utilizing the Cre/lox recombination system with AAV vectors will enable selective tagging of dopaminergic neurons with iRFP for detection in brain slices using PAM. Thus, providing a new means of increasing the depth at which neuronal subtypes can be imaged and detected in the mammalian brain. Significance: Knowledge gained from this research could have significant impacts on the PA detection of ovarian cancer and extend the depth at which neuronal subtypes are imaged in the mammalian brain.
ContributorsLusk, Joel F. (Author) / Smith, Barbara S. (Thesis advisor) / Halden, Rolf (Committee member) / Anderson, Trent (Committee member) / Arizona State University (Publisher)
Created2022
171888-Thumbnail Image.png
Description
Computational models have long been used to describe and predict the outcome of complex immunological processes. The dissertation work described here centers on the construction of multiscale computational immunology models that derives biological insights at the population, systems, and atomistic levels. First, SARS-CoV-2 mortality is investigated through the lens of

Computational models have long been used to describe and predict the outcome of complex immunological processes. The dissertation work described here centers on the construction of multiscale computational immunology models that derives biological insights at the population, systems, and atomistic levels. First, SARS-CoV-2 mortality is investigated through the lens of the predicted robustness of CD8+ T cell responses in 23 different populations. The robustness of CD8+ T cell responses in a given population was modeled by predicting the efficiency of endemic MHC-I protein variants to present peptides derived from SARS-CoV-2 proteins to circulating T cells. To accomplish this task, an algorithm, called EnsembleMHC, was developed to predict viral peptides with a high probability of being recognized by CD T cells. It was discovered that there was significant variation in the efficiency of different MHC-I protein variants to present SARS-CoV-2 derived peptides, and countries enriched with variants with high presentation efficiency had significantly lower mortality rates. Second, a biophysics-based MHC-I peptide prediction algorithm was developed. The MHC-I protein is the most polymorphic protein in the human genome with polymorphisms in the peptide binding causing striking changes in the amino acid compositions, or binding motifs, of peptide species capable of stable binding. A deep learning model, coined HLA-Inception, was trained to predict peptide binding using only biophysical properties, namely electrostatic potential. HLA-Inception was shown to be extremely accurate and efficient at predicting peptide binding motifs and was used to determine the peptide binding motifs of 5,821 MHC-I protein variants. Finally, the impact of stalk glycosylations on NL63 protein dynamics was investigated. Previous data has shown that coronavirus crown glycans play an important role in immune evasion and receptor binding, however, little is known about the role of the stalk glycans. Through the integration of computational biology, experimental data, and physics-based simulations, the stalk glycans were shown to heavily influence the bending angle of spike protein, with a particular emphasis on the glycan at position 1242. Further investigation revealed that removal of the N1242 glycan significantly reduced infectivity, highlighting a new potential therapeutic target. Overall, these investigations and associated innovations in integrative modeling.
ContributorsWilson, Eric Andrew (Author) / Anderson, Karen (Thesis advisor) / Singharoy, Abhishek (Thesis advisor) / Woodbury, Neal (Committee member) / Sulc, Petr (Committee member) / Arizona State University (Publisher)
Created2022
190962-Thumbnail Image.png
Description
Wastewater-based epidemiology (WBE) has emerged as a powerful tool for community health assessment, using wastewater-borne biological and chemical markers as analytical targets. This study investigates the critical influence of sampling frequency on the resultant estimates of opioid consumption and the prevalence of SARS-CoV-2 infections at the neighborhood level using common

Wastewater-based epidemiology (WBE) has emerged as a powerful tool for community health assessment, using wastewater-borne biological and chemical markers as analytical targets. This study investigates the critical influence of sampling frequency on the resultant estimates of opioid consumption and the prevalence of SARS-CoV-2 infections at the neighborhood level using common WBE biomarkers including fentanyl, norfentanyl, and the SARS-CoV-2 N1 gene as targets. The goal was to assess sampling methodologies that include the impact of the day of the week and of the sampling frequency. Wastewater samples were collected two or three times per week over the course of five months (n=525) and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) or reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) for target chemical or molecular indicators of interest. Results showed no statistically significant differences for days of the week (i.e., Tuesday vs. Thursday vs. Saturday) for 24-hour composite samples analyzed for fentanyl or SARS-CoV-2; however, concentrations of the human metabolite of fentanyl, norfentanyl, were statistically different between Tuesday and Saturday (p < 0.05). When data were aggregated either by Tuesday/Thursday or Tuesday/Thursday/Saturday to examine sensitivity to sampling frequency, data were not statistically different except for the Tuesday/Thursday weekly average and Saturday for norfentanyl (p < 0.05). These results highlight how sample collection and data handling methodologies can impact wastewater-derived public health assessments. Care should be taken when selecting an approach to the sampling frequency based on the public health concerns under investigation.
ContributorsAJDINI, ARIANNA (Author) / Halden, Rolf (Thesis advisor) / Driver, Erin (Committee member) / Conroy-Ben, Otakuye (Committee member) / Arizona State University (Publisher)
Created2023
Description
Current methods for quantifying microplastics via LC-MS/MS analysis have been adapted from environmental monitoring protocols and are often inadequate for sampling within complex matrices. This study explores the application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of microplastics. The initial phase of this research utilized pork kidney

Current methods for quantifying microplastics via LC-MS/MS analysis have been adapted from environmental monitoring protocols and are often inadequate for sampling within complex matrices. This study explores the application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of microplastics. The initial phase of this research utilized pork kidney samples to establish a baseline for background and efficacy of sample processing. These findings underscore the complexity of developing a sensitive and specific analytical technique for microplastics in tissues. The observed discrepancies in contamination and replicability between samples emphasize the need for continual method optimization.
ContributorsBabbrah, Ayesha (Author) / Halden, Rolf (Thesis director) / Newell, Melanie (Committee member) / Barrett, The Honors College (Contributor) / School of Life Sciences (Contributor)
Created2023-12
189363-Thumbnail Image.png
Description
This dissertation focused on studying risks associated with emerging drinking water contaminants and tradeoffs related to water management interventions. The built environment impacts health, as humans on average spend ~90% of their time indoors. Federal regulations generally focus on drinking water at the water treatment plant and within the distribution

This dissertation focused on studying risks associated with emerging drinking water contaminants and tradeoffs related to water management interventions. The built environment impacts health, as humans on average spend ~90% of their time indoors. Federal regulations generally focus on drinking water at the water treatment plant and within the distribution system as opposed to when it enters buildings after crossing the property line. If drinking water is not properly managed in buildings, it can be a source or amplifier of microbial and chemical contaminants. Unlike regulations for chemical contaminants that are risk-based, for pathogens, regulations are either based on recommended treatment technologies or designated as zero, which is not achievable in practice. Practice-based judgments are typically made at the building level to maintain water quality. This research focuses on two drinking water opportunistic pathogens of public health concern, Legionella pneumophila and Mycobacterium avium complex (MAC). Multiple aspects of drinking water quality in two green buildings were monitored in tandem with water management interventions. Additionally, a quantitative microbial risk assessment framework was used to predict risk-based critical concentrations of MAC for drinking water-related exposures in the indoor environment corresponding to a 1 in 10,000 annual infection target risk benchmark. The overall goal of this work was to inform the development of water management plans and guidelines for buildings that will improve water quality in the built environment and promote better public health. It was determined that a whole building water softening system with ion exchange softening resin and expansion tanks were unexplored reservoirs for the colonization of L. pneumophila. Furthermore, it was observed that typical water management interventions such as flushing and thermal disinfection did not always mitigate water quality issues. Thus, there was a need to implement several atypical interventions such as equipment replacement to improve the building water quality. This work has contributed comprehensive field studies and models that have highlighted the need for additional niches, facility management challenges, and risk tradeoffs for focus in water safety plans. The work also informs additional risk-based water quality policy approaches for reducing drinking water risks.
ContributorsJoshi, Sayalee (Author) / Hamilton, Kerry A (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Conroy-Ben, Otakuye (Committee member) / Halden, Rolf (Committee member) / Arizona State University (Publisher)
Created2023
Description

Synthetic plastics are ubiquitously used in a broad range of applications, including food and drink packaging. Plastics often contain chemical additives, including bisphenols, phthalates, and terephthalic acid, which can degrade under thermal stress. The environmental presence of these chemicals is cause for public concern, especially in consumer products that utilize

Synthetic plastics are ubiquitously used in a broad range of applications, including food and drink packaging. Plastics often contain chemical additives, including bisphenols, phthalates, and terephthalic acid, which can degrade under thermal stress. The environmental presence of these chemicals is cause for public concern, especially in consumer products that utilize plastic packaging, as many have been identified as endocrine disruptors. This study sought to determine exposure to phthalates, bisphenols, and terephthalic acid by quantifying a broad spectrum of these analytes within three bottled water brands at varying temperature exposure levels using the combination of solid phase extraction followed by isotope dilution liquid chromatography-tandem mass spectrometry. Monobenzyl phthalate was detected in two of the three brands after bottles were heated to ~100 °C, ranging from 98 – 107 ng/L, and bisphenol A was detected in one brand at ~100 °C at an average concentration of 748 ± 36 ng/L. Subsequent mass loading calculations demonstrated that bioaccumulation of BPA from Brand C after high levels of temperature exposure well exceeded the tolerable daily intake (TDI). Findings in this study indicate that consumers should not be expected to incur harmful exposures to the target compounds under normal conditions as analytes were not measured in water bottle samples at 25 °C or 60 °C. Further studies should explore a more nuisance approach to heating over long durations, including that of ultraviolet exposure.

ContributorsZevitz, Jacob (Author) / Halden, Rolf (Thesis director) / Driver, Erin (Committee member) / Barrett, The Honors College (Contributor) / School of International Letters and Cultures (Contributor) / School of Life Sciences (Contributor)
Created2022-12
Description
The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates

The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates a variety of environmental problems such as substance runoff and ocean pollution. The objective of this study was to evaluate the efficacy of possible solutions for minimizing micropipette tip and disposable glove waste within laboratory spaces. It was hypothesized that simultaneously implementing the use of micropipette tip washers (MTWs) and energy-from-glove-waste programs (EGWs) would significantly reduce (p < 0.05) the average combined annual single-use plastic micropipette tip and nitrile glove waste (in kg) per square meter of laboratory space in the United States. ASU’s Biodesign Institute (BDI) was used as a case study to inform on the thousands of different laboratory facilities that exist all across the United States. Four separate research laboratories within the largest public university of the U.S. were sampled to assess the volume of plastic waste from single-use micropipette tips and gloves. Resultant data were used to represent the totality of single-use waste from the case study location and then extrapolated to all laboratory space in the United States. With the implementation of EGWs, annual BDI glove waste is reduced by 100% (0.47 ± 0.26 kg/m2; 35.5 ± 19.3 metric tons total) and annual BDI glove-related carbon emissions are reduced by ~5.01% (0.165 ± 0.09 kg/m2; 1.24 ± 0.68 metric tons total). With the implementation of MTWs, annual BDI micropipette tip waste is reduced by 92% (0.117 ± 0.03 kg/m2; 0.88 ± 0.25 metric tons total) and annual BDI tip-related carbon emissions are reduced by ~83.6% (4.04 ± 1.25 kg/m2; 30.5 ± 9.43 metric tons total). There was no significant difference (p = 0.06) observed between the mass of single-use waste (kg) in the sampled laboratory spaces before (x̄ = 47.1; σ = 43.3) and after (x̄ =0.070; σ = 0.033) the implementation of the solutions. When examining both solutions (MTWs & EGWs) implemented in conjunction with one another, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$7.92 ± $9.31/m2 (7,500 m2 of total wet laboratory space) or ~$60,000 ± $70,000 total. These savings represent ~15.77% of annual BDI spending on micropipette tips and nitrile gloves. The large error margins in these financial estimates create high uncertainty for whether or not BDI would see net savings from implementing both solutions simultaneously. However, when examining the implementation of only MTWs, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$12.01 ± $6.79 kg/m2 or ~$91,000 ± $51,200 total. These savings represent ~23.92% of annual BDI spending on micropipette tips and nitrile gloves. The lower error margins for this estimate create a much higher likelihood of net savings for BDI. Extrapolating to all laboratory space in the United States, the total annual amount of plastic waste avoided with the implementation of the MTWs was identified as 8,130 ± 2,290 tons or 0.023% of all solid plastic waste produced in the United States in 2018. The total amount of nitrile waste avoided with the implementation of the EGWs was identified as 32,800 ± 17,900 tons or 0.36% of all rubber solid waste produced in the United States in 2018. The total amount of carbon emissions avoided with the implementation of the MTWs was identified as 281,000 ± 87,000 tons CO2eq or 5.4*10-4 % of all CO2eq GHG emissions produced in the United States in 2020. Both the micropipette tip washer and the glove waste avoidance program solutions can be easily integrated into existing laboratories without compromising the integrity of the activities taking place. Implemented on larger scales, these solutions hold the potential for significant single-use waste reduction.
ContributorsZdrale, Gabriel (Author) / Mahant, Akhil (Co-author) / Halden, Rolf (Thesis director) / Biyani, Nivedita (Committee member) / Driver, Erin (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05
Description
The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates

The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates a variety of environmental problems such as substance runoff and ocean pollution. The objective of this study was to evaluate the efficacy of possible solutions for minimizing micropipette tip and disposable glove waste within laboratory spaces. It was hypothesized that simultaneously implementing the use of micropipette tip washers (MTWs) and energy-from-glove-waste programs (EGWs) would significantly reduce (p < 0.05) the average combined annual single-use plastic micropipette tip and nitrile glove waste (in kg) per square meter of laboratory space in the United States. ASU’s Biodesign Institute (BDI) was used as a case study to inform on the thousands of different laboratory facilities that exist all across the United States. Four separate research laboratories within the largest public university of the U.S. were sampled to assess the volume of plastic waste from single-use micropipette tips and gloves. Resultant data were used to represent the totality of single-use waste from the case study location and then extrapolated to all laboratory space in the United States. With the implementation of EGWs, annual BDI glove waste is reduced by 100% (0.47 ± 0.26 kg/m2; 35.5 ± 19.3 metric tons total) and annual BDI glove-related carbon emissions are reduced by ~5.01% (0.165 ± 0.09 kg/m2; 1.24 ± 0.68 metric tons total). With the implementation of MTWs, annual BDI micropipette tip waste is reduced by 92% (0.117 ± 0.03 kg/m2; 0.88 ± 0.25 metric tons total) and annual BDI tip-related carbon emissions are reduced by ~83.6% (4.04 ± 1.25 kg/m2; 30.5 ± 9.43 metric tons total). There was no significant difference (p = 0.06) observed between the mass of single-use waste (kg) in the sampled laboratory spaces before (x̄ = 47.1; σ = 43.3) and after (x̄ =0.070; σ = 0.033) the implementation of the solutions.When examining both solutions (MTWs & EGWs) implemented in conjunction with one another, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$7.92 ± $9.31/m2 (7,500 m2 of total wet laboratory space) or ~$60,000 ± $70,000 total. These savings represent ~15.77% of annual BDI spending on micropipette tips and nitrile gloves. The large error margins in these financial estimates create high uncertainty for whether or not BDI would see net savings from implementing both solutions simultaneously. However, when examining the implementation of only MTWs, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$12.01 ± $6.79 kg/m2 or ~$91,000 ± $51,200 total. These savings represent ~23.92% of annual BDI spending on micropipette tips and nitrile gloves. The lower error margins for this estimate create a much higher likelihood of net savings for BDI. Extrapolating to all laboratory space in the United States, the total annual amount of plastic waste avoided with the implementation of the MTWs was identified as 8,130 ± 2,290 tons or 0.023% of all solid plastic waste produced in the United States in 2018. The total amount of nitrile waste avoided with the implementation of the EGWs was identified as 32,800 ± 17,900 tons or 0.36% of all rubber solid waste produced in the United States in 2018. The total amount of carbon emissions avoided with the implementation of the MTWs was identified as 281,000 ± 87,000 tons CO2eq or 5.4*10-4 % of all CO2eq GHG emissions produced in the United States in 2020. Both the micropipette tip washer and the glove waste avoidance program solutions can be easily integrated into existing laboratories without compromising the integrity of the activities taking place. Implemented on larger scales, these solutions hold the potential for significant single-use waste reduction.
ContributorsMahant, Akhil (Author) / Zdrale, Gabriel (Co-author) / Halden, Rolf (Thesis director) / Biyani, Nivedita (Committee member) / Driver, Erin (Committee member) / Barrett, The Honors College (Contributor) / School of International Letters and Cultures (Contributor) / School of Life Sciences (Contributor)
Created2022-05
165750-Thumbnail Image.png
Description

Diabetes affects millions of people globally and can lead to other severe health complications when undiagnosed or not properly managed. The incidence of diabetes has rapidly increased over the past several years, however, not all individuals have access to affordable or convenient healthcare. We hypothesize that wastewater-based epidemiology (WBE) has

Diabetes affects millions of people globally and can lead to other severe health complications when undiagnosed or not properly managed. The incidence of diabetes has rapidly increased over the past several years, however, not all individuals have access to affordable or convenient healthcare. We hypothesize that wastewater-based epidemiology (WBE) has the potential to assess community health status by analyzing biomarkers indicative of human health and disease, including diabetes. Used in tandem with current methods, monitoring indicators of diabetes in community wastewater could provide a comprehensive assessment tool for disease prevalence in large and small populations. Specifically, the proposed targeted biomarker evaluated in this study to indicate population-wide diabetes prevalence was 8-hydroxy-2’- deoxyguanosine (8-OHdG). This work combines a rigorous literature review and initial laboratory studies to explore the possibility of diabetes monitoring at the community level using WBE. Here, 24-hour composite wastewater samples were collected from within two wastewater sub-catchments of Greater Tempe, AZ. Overall goals of this study were to: i) Determine the feasibility to detect endogenous markers of diabetes in community wastewater; ii) Assess the potential impact of confounding factors, such as smoking, cancer, and atherosclerosis, through a literature analysis; and iii) Evaluate the socioeconomic status and demographics of the study population. Preliminary results of the experiments suggest this methodology to be feasible, as indicated by the observation of detectable signals of 8-OHdG in community wastewater collected from the sewer infrastructure; however, future work and continued experimentation will be required to address low signal intensity and assay precision and accuracy. Thus, the work presented here provides valuable proof-of-concept data, with detailed information on the method employed and identified opportunities to further determine the relationship between 8-OHdG concentrations in municipal wastewater and diabetes prevalence at the community level.

ContributorsNguyen, Jasmine (Author) / John, Dona (Co-author) / Halden, Rolf (Thesis director) / Driver, Erin (Committee member) / Bowes, Devin (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor) / Dean, W.P. Carey School of Business (Contributor) / Department of Finance (Contributor)
Created2022-05