Matching Items (140)
190962-Thumbnail Image.png
Description
Wastewater-based epidemiology (WBE) has emerged as a powerful tool for community health assessment, using wastewater-borne biological and chemical markers as analytical targets. This study investigates the critical influence of sampling frequency on the resultant estimates of opioid consumption and the prevalence of SARS-CoV-2 infections at the neighborhood level using common

Wastewater-based epidemiology (WBE) has emerged as a powerful tool for community health assessment, using wastewater-borne biological and chemical markers as analytical targets. This study investigates the critical influence of sampling frequency on the resultant estimates of opioid consumption and the prevalence of SARS-CoV-2 infections at the neighborhood level using common WBE biomarkers including fentanyl, norfentanyl, and the SARS-CoV-2 N1 gene as targets. The goal was to assess sampling methodologies that include the impact of the day of the week and of the sampling frequency. Wastewater samples were collected two or three times per week over the course of five months (n=525) and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) or reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) for target chemical or molecular indicators of interest. Results showed no statistically significant differences for days of the week (i.e., Tuesday vs. Thursday vs. Saturday) for 24-hour composite samples analyzed for fentanyl or SARS-CoV-2; however, concentrations of the human metabolite of fentanyl, norfentanyl, were statistically different between Tuesday and Saturday (p < 0.05). When data were aggregated either by Tuesday/Thursday or Tuesday/Thursday/Saturday to examine sensitivity to sampling frequency, data were not statistically different except for the Tuesday/Thursday weekly average and Saturday for norfentanyl (p < 0.05). These results highlight how sample collection and data handling methodologies can impact wastewater-derived public health assessments. Care should be taken when selecting an approach to the sampling frequency based on the public health concerns under investigation.
ContributorsAJDINI, ARIANNA (Author) / Halden, Rolf (Thesis advisor) / Driver, Erin (Committee member) / Conroy-Ben, Otakuye (Committee member) / Arizona State University (Publisher)
Created2023
190909-Thumbnail Image.png
Description
Dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) are crucial nutrients for autotrophic and heterotrophic microbial life, respectively, in hydrothermal systems. Biogeochemical processes that control amounts of DIC and DOC in Yellowstone hot springs can be investigated by measuring carbon abundances and respective isotopic values. A decade and a

Dissolved inorganic carbon (DIC) and dissolved organic carbon (DOC) are crucial nutrients for autotrophic and heterotrophic microbial life, respectively, in hydrothermal systems. Biogeochemical processes that control amounts of DIC and DOC in Yellowstone hot springs can be investigated by measuring carbon abundances and respective isotopic values. A decade and a half of field work in 10 regions within Yellowstone National Park and subsequent geochemical lab analyses reveal that sulfate-dominant acidic regions have high DOC (Up to 57 ppm C) and lower DIC (up to 50 ppm C) compared to neutral-chloride regions with low DOC (< 2 ppm C) and higher DIC (up to 100 ppm C). Abundances and isotopic data suggest that sedimentary rock erosion by acidic hydrothermal fluids, fresh snow-derived meteoric water, and exogenous carbon input allowed by local topography may affect DOC levels. Evaluating the isotopic compositions of DIC and DOC in hydrothermal fluids gives insight on the geology and microbial life in the subsurface between different regions. DIC δ13C values range from -4‰ to +5‰ at pH 5-9 and from -10‰ to +3‰ at pH 2-5 with several springs lower than -10‰. DOC δ13C values parkwide range from -10‰ to -30‰. Within this range, neutral-chloride regions in the Lower Geyser Basin have lighter isotopes than sulfate-dominant acidic regions. In hot springs with elevated levels of DOC, the range only varies between -20‰ and -26‰ which may be caused by local exogenous organic matter runoff. Combining other geochemical measurements, such as differences in chloride and sulfate concentrations, demonstrates that some regions contain mixtures of multiple fluids moving through the complex hydrological system in the subsurface. The mixing of these fluids may account for increased levels of DOC in meteoric sulfate-dominant acidic regions. Ultimately, the foundational values of dissolved carbon and their isotopic composition is provided in a parkwide study, so results can be combined with future studies that apply different sequencing analyses to understand specific biogeochemical cycling and microbial communities that occur in individual hot springs.
ContributorsBarnes, Tanner (Author) / Shock, Everett (Thesis advisor) / Meyer-Dombard, D'Arcy (Committee member) / Hartnett, Hilairy (Committee member) / Arizona State University (Publisher)
Created2023
Description
Current methods for quantifying microplastics via LC-MS/MS analysis have been adapted from environmental monitoring protocols and are often inadequate for sampling within complex matrices. This study explores the application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of microplastics. The initial phase of this research utilized pork kidney

Current methods for quantifying microplastics via LC-MS/MS analysis have been adapted from environmental monitoring protocols and are often inadequate for sampling within complex matrices. This study explores the application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of microplastics. The initial phase of this research utilized pork kidney samples to establish a baseline for background and efficacy of sample processing. These findings underscore the complexity of developing a sensitive and specific analytical technique for microplastics in tissues. The observed discrepancies in contamination and replicability between samples emphasize the need for continual method optimization.
ContributorsBabbrah, Ayesha (Author) / Halden, Rolf (Thesis director) / Newell, Melanie (Committee member) / Barrett, The Honors College (Contributor) / School of Life Sciences (Contributor)
Created2023-12
189340-Thumbnail Image.png
Description
As air quality standards become more stringent to combat poor air quality, there is a greater need for more effective pollutant control measures and increased air monitoring network coverage. Polluted air, in the form of aerosols and gases, can impact respiratory and cardiovascular health, visibility, the climate, and material weathering.

As air quality standards become more stringent to combat poor air quality, there is a greater need for more effective pollutant control measures and increased air monitoring network coverage. Polluted air, in the form of aerosols and gases, can impact respiratory and cardiovascular health, visibility, the climate, and material weathering. This work demonstrates how traditional networks can be used to study generational events, how these networks can be supplemented with low-cost sensors, and the effectiveness of several control measures. First, an existing network was used to study the effect of COVID-19 travel restrictions on air quality in Maricopa County, Arizona, which would not have been possible without the historical record that a traditional network provides. Although this study determined that decreases in CO and NO2 were not unique to the travel restrictions, it was limited to only three locations due to network sparseness. The second part of this work expanded the traditional NO2 monitoring network using low-cost sensors, that were first collocated with a reference monitor to evaluate their performance and establish a robust calibration. The sensors were then deployed to the field to varying results; their calibration was further improved by cycling the sensors between deployment and reference locations throughout the summer. This calibrated NO2 data, along with volatile organic compound data, were combined to enhance the understanding of ozone formation in Maricopa County, especially during wildfire season. In addition to being in non-attainment for ozone standards, Maricopa County fails to meet particulate matter under 10 μm (PM10) standards. A large portion of PM10 emissions is attributed to fugitive dust that is either windblown or kicked up by vehicles. The third part of this work demonstrated that Enzyme Induced Carbonate Precipitation (EICP) treatments aggregate soil particles and prevent fugitive dust emissions. The final part of the work examined tire wear PM10 emissions, as vehicles are another significant contributor to PM10. Observations showed a decrease in tire wear PM10 during winter with little change when varying the highway surface type.
ContributorsMiech, Jason Andrew (Author) / Herckes, Pierre (Thesis advisor) / Fraser, Matthew P (Committee member) / Shock, Everett (Committee member) / Arizona State University (Publisher)
Created2023
189350-Thumbnail Image.png
Description
The prevalence and unique properties of airborne nanoparticles have raised concerns regarding their potential adverse health effects. Despite their significance, the understanding of nanoparticle generation, transport, and exposure remains incomplete. This study first aimed to assess nanoparticle exposure in indoor workplace environments, in the semiconductor manufacturing industry. On-site observations during

The prevalence and unique properties of airborne nanoparticles have raised concerns regarding their potential adverse health effects. Despite their significance, the understanding of nanoparticle generation, transport, and exposure remains incomplete. This study first aimed to assess nanoparticle exposure in indoor workplace environments, in the semiconductor manufacturing industry. On-site observations during tool preventive maintenance revealed a significant release of particles smaller than 30 nm, which subsequent instrumental analysis confirmed as predominantly composed of transition metals. Although the measured mass concentration levels did not exceed current federal limits, it prompted concerns regarding how well filter-based air sampling methods would capture the particles for exposure assessment and how well common personal protective equipment would protect from exposure. To address these concerns, this study evaluated the capture efficiency of filters and masks. When challenged by aerosolized engineered nanomaterials, common filters used in industrial hygiene sampling exhibited capture efficiencies of over 60%. Filtering Facepiece Respirators, such as the N95 mask, exhibited a capture efficiency of over 98%. In contrast, simple surgical masks showed a capture efficiency of approximately 70%. The experiments showed that face velocity and ambient humidity influence capture performance and mostly identified the critical role of mask and particle surface charge in capturing nanoparticles. Masks with higher surface potential exhibited higher capture efficiency towards nanoparticles. Eliminating their surface charge resulted in a significantly diminished capture efficiency, up to 43%. Finally, this study characterized outdoor nanoparticle concentrations in the Phoenix metropolitan area, revealing typical concentrations on the order of 10^4 #/cm3 consistent with other urban environments. During the North American monsoon season, in dust storms, with elevated number concentrations of large particles, particularly in the size range of 1-10 μm, the number concentration of nanoparticles in the size range of 30-100 nm was substantially lower by approximately 55%. These findings provide valuable insights for future assessments of nanoparticle exposure risks and filter capture mechanisms associated with airborne nanoparticles.
ContributorsZhang, Zhaobo (Author) / Herckes, Pierre (Thesis advisor) / Westerhoff, Paul (Committee member) / Shock, Everett (Committee member) / Fraser, Matthew (Committee member) / Arizona State University (Publisher)
Created2023
189363-Thumbnail Image.png
Description
This dissertation focused on studying risks associated with emerging drinking water contaminants and tradeoffs related to water management interventions. The built environment impacts health, as humans on average spend ~90% of their time indoors. Federal regulations generally focus on drinking water at the water treatment plant and within the distribution

This dissertation focused on studying risks associated with emerging drinking water contaminants and tradeoffs related to water management interventions. The built environment impacts health, as humans on average spend ~90% of their time indoors. Federal regulations generally focus on drinking water at the water treatment plant and within the distribution system as opposed to when it enters buildings after crossing the property line. If drinking water is not properly managed in buildings, it can be a source or amplifier of microbial and chemical contaminants. Unlike regulations for chemical contaminants that are risk-based, for pathogens, regulations are either based on recommended treatment technologies or designated as zero, which is not achievable in practice. Practice-based judgments are typically made at the building level to maintain water quality. This research focuses on two drinking water opportunistic pathogens of public health concern, Legionella pneumophila and Mycobacterium avium complex (MAC). Multiple aspects of drinking water quality in two green buildings were monitored in tandem with water management interventions. Additionally, a quantitative microbial risk assessment framework was used to predict risk-based critical concentrations of MAC for drinking water-related exposures in the indoor environment corresponding to a 1 in 10,000 annual infection target risk benchmark. The overall goal of this work was to inform the development of water management plans and guidelines for buildings that will improve water quality in the built environment and promote better public health. It was determined that a whole building water softening system with ion exchange softening resin and expansion tanks were unexplored reservoirs for the colonization of L. pneumophila. Furthermore, it was observed that typical water management interventions such as flushing and thermal disinfection did not always mitigate water quality issues. Thus, there was a need to implement several atypical interventions such as equipment replacement to improve the building water quality. This work has contributed comprehensive field studies and models that have highlighted the need for additional niches, facility management challenges, and risk tradeoffs for focus in water safety plans. The work also informs additional risk-based water quality policy approaches for reducing drinking water risks.
ContributorsJoshi, Sayalee (Author) / Hamilton, Kerry A (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Conroy-Ben, Otakuye (Committee member) / Halden, Rolf (Committee member) / Arizona State University (Publisher)
Created2023
Description

Synthetic plastics are ubiquitously used in a broad range of applications, including food and drink packaging. Plastics often contain chemical additives, including bisphenols, phthalates, and terephthalic acid, which can degrade under thermal stress. The environmental presence of these chemicals is cause for public concern, especially in consumer products that utilize

Synthetic plastics are ubiquitously used in a broad range of applications, including food and drink packaging. Plastics often contain chemical additives, including bisphenols, phthalates, and terephthalic acid, which can degrade under thermal stress. The environmental presence of these chemicals is cause for public concern, especially in consumer products that utilize plastic packaging, as many have been identified as endocrine disruptors. This study sought to determine exposure to phthalates, bisphenols, and terephthalic acid by quantifying a broad spectrum of these analytes within three bottled water brands at varying temperature exposure levels using the combination of solid phase extraction followed by isotope dilution liquid chromatography-tandem mass spectrometry. Monobenzyl phthalate was detected in two of the three brands after bottles were heated to ~100 °C, ranging from 98 – 107 ng/L, and bisphenol A was detected in one brand at ~100 °C at an average concentration of 748 ± 36 ng/L. Subsequent mass loading calculations demonstrated that bioaccumulation of BPA from Brand C after high levels of temperature exposure well exceeded the tolerable daily intake (TDI). Findings in this study indicate that consumers should not be expected to incur harmful exposures to the target compounds under normal conditions as analytes were not measured in water bottle samples at 25 °C or 60 °C. Further studies should explore a more nuisance approach to heating over long durations, including that of ultraviolet exposure.

ContributorsZevitz, Jacob (Author) / Halden, Rolf (Thesis director) / Driver, Erin (Committee member) / Barrett, The Honors College (Contributor) / School of International Letters and Cultures (Contributor) / School of Life Sciences (Contributor)
Created2022-12
168758-Thumbnail Image.png
Description
Lithium (Li) is a trace element in kerogen, but the content and isotopic distribution (δ7Li) in kerogen has not previously been quantified. Furthermore, kerogen has been overlooked as a potential source of Li to sedimentary porefluids and buried sediments. Thus, knowing the content and isotopic composition of Li derived from

Lithium (Li) is a trace element in kerogen, but the content and isotopic distribution (δ7Li) in kerogen has not previously been quantified. Furthermore, kerogen has been overlooked as a potential source of Li to sedimentary porefluids and buried sediments. Thus, knowing the content and isotopic composition of Li derived from kerogen may have implications for research focused on the Li-isotopes of buried sediments (e.g., evaluating paleoclimate variations using marine carbonates).The objective of this work is to better understand the role of kerogen in the Li geochemical cycle. The research approach consisted of 1) developing reference materials and methodologies to measure the Li-contents and δ7Li of kerogen in-situ by Secondary Ion Mass Spectrometry, 2) surveying the Li-contents and δ7Li of kerogen bearing rocks from different depositional and diagenetic environments and 3) quantifying the Li-content and δ7Li variations in kerogen empirically in a field study and 4) experimentally through hydrous pyrolysis. A survey of δ7Li of coals from depositional basins across the USA showed that thermally immature coals have light δ7Li values (–20 to – 10‰) compared to typical terrestrial materials (> –10‰) and the δ7Li of coal increases with burial temperature suggesting that 6Li is preferentially released from kerogen to porefluids during hydrocarbon generation. A field study was conducted on two Cretaceous coal seams in Colorado (USA) intruded by dikes (mafic and felsic) creating a temperature gradient from the intrusives into the country rock. Results showed that δ7Li values of the unmetamorphosed vitrinite macerals were up to 37‰ lighter than vitrinite macerals and coke within the contact metamorphosed coal. To understand the significance of Li derived from kerogen during burial diagenesis, hydrous pyrolysis experiments of three coals were conducted. Results showed that Li is released from kerogen during hydrocarbon generation and could increase sedimentary porefluid Li-contents up to ~100 mg/L. The δ7Li of coals becomes heavier with increased temperature except where authigenic silicates may compete for the released Li. These results indicate that kerogen is a significant source of isotopically light Li to diagenetic fluids and is an important contributor to the global geochemical cycle.
ContributorsTeichert, Zebadiah (Author) / Williams, Lynda B. (Thesis advisor) / Bose, Maitrayee (Thesis advisor) / Hervig, Richard (Committee member) / Semken, Steven (Committee member) / Shock, Everett (Committee member) / Arizona State University (Publisher)
Created2022
Description
The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates

The production and incineration of single-use micropipette tips and disposable gloves, which are heavily used within laboratory facilities, generate large amounts of greenhouse gasses (GHGs) and accelerate climate change. Plastic waste that is not incinerated often is lost in the environment. The long degradation times associated with this waste exacerbates a variety of environmental problems such as substance runoff and ocean pollution. The objective of this study was to evaluate the efficacy of possible solutions for minimizing micropipette tip and disposable glove waste within laboratory spaces. It was hypothesized that simultaneously implementing the use of micropipette tip washers (MTWs) and energy-from-glove-waste programs (EGWs) would significantly reduce (p < 0.05) the average combined annual single-use plastic micropipette tip and nitrile glove waste (in kg) per square meter of laboratory space in the United States. ASU’s Biodesign Institute (BDI) was used as a case study to inform on the thousands of different laboratory facilities that exist all across the United States. Four separate research laboratories within the largest public university of the U.S. were sampled to assess the volume of plastic waste from single-use micropipette tips and gloves. Resultant data were used to represent the totality of single-use waste from the case study location and then extrapolated to all laboratory space in the United States. With the implementation of EGWs, annual BDI glove waste is reduced by 100% (0.47 ± 0.26 kg/m2; 35.5 ± 19.3 metric tons total) and annual BDI glove-related carbon emissions are reduced by ~5.01% (0.165 ± 0.09 kg/m2; 1.24 ± 0.68 metric tons total). With the implementation of MTWs, annual BDI micropipette tip waste is reduced by 92% (0.117 ± 0.03 kg/m2; 0.88 ± 0.25 metric tons total) and annual BDI tip-related carbon emissions are reduced by ~83.6% (4.04 ± 1.25 kg/m2; 30.5 ± 9.43 metric tons total). There was no significant difference (p = 0.06) observed between the mass of single-use waste (kg) in the sampled laboratory spaces before (x̄ = 47.1; σ = 43.3) and after (x̄ =0.070; σ = 0.033) the implementation of the solutions. When examining both solutions (MTWs & EGWs) implemented in conjunction with one another, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$7.92 ± $9.31/m2 (7,500 m2 of total wet laboratory space) or ~$60,000 ± $70,000 total. These savings represent ~15.77% of annual BDI spending on micropipette tips and nitrile gloves. The large error margins in these financial estimates create high uncertainty for whether or not BDI would see net savings from implementing both solutions simultaneously. However, when examining the implementation of only MTWs, the annual BDI financial savings (in regard to both purchasing and disposal costs) after the first year were determined to be ~$12.01 ± $6.79 kg/m2 or ~$91,000 ± $51,200 total. These savings represent ~23.92% of annual BDI spending on micropipette tips and nitrile gloves. The lower error margins for this estimate create a much higher likelihood of net savings for BDI. Extrapolating to all laboratory space in the United States, the total annual amount of plastic waste avoided with the implementation of the MTWs was identified as 8,130 ± 2,290 tons or 0.023% of all solid plastic waste produced in the United States in 2018. The total amount of nitrile waste avoided with the implementation of the EGWs was identified as 32,800 ± 17,900 tons or 0.36% of all rubber solid waste produced in the United States in 2018. The total amount of carbon emissions avoided with the implementation of the MTWs was identified as 281,000 ± 87,000 tons CO2eq or 5.4*10-4 % of all CO2eq GHG emissions produced in the United States in 2020. Both the micropipette tip washer and the glove waste avoidance program solutions can be easily integrated into existing laboratories without compromising the integrity of the activities taking place. Implemented on larger scales, these solutions hold the potential for significant single-use waste reduction.
ContributorsZdrale, Gabriel (Author) / Mahant, Akhil (Co-author) / Halden, Rolf (Thesis director) / Biyani, Nivedita (Committee member) / Driver, Erin (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05
165679-Thumbnail Image.png
Description
The Greater Obsidian Pool Area just south of the Mud Volcano area in Yellowstone National Park is an active and ever-changing hot spring region. Situated next to a lake in a meadow between several hills of glacial deposits, north of the Elephant Back rhyolite flow, a diverse group of hot

The Greater Obsidian Pool Area just south of the Mud Volcano area in Yellowstone National Park is an active and ever-changing hot spring region. Situated next to a lake in a meadow between several hills of glacial deposits, north of the Elephant Back rhyolite flow, a diverse group of hot springs has been developing. This study examines the geologic and geomorphic context of the hot springs, finding evidence for a previously undiscovered hydrothermal explosion crater and examining the deposits around the region that contribute to properties of the groundwater table. Hot spring geochemical measurements (Cl- and SO4-2) taken over the course of 20 years are used to determine fluid sourcing of the springs. The distribution of Cl-, an indicator of water-rock interaction, in the hot springs leads to the theory of a fissure delivering hydrothermal fluid in a line across the hot spring zone, with meteoric water from incoming groundwater diluting hot springs moving further from the fissure. A possible second dry fissure delivering mostly gas is also a possible explanation for some elevated sulfate concentrations in certain springs. The combination of geology, geomorphology, and geochemistry reveals how the surface and subsurface operate to generate different hot spring compositions.
ContributorsAlexander, Erin (Author) / Shock, Everett (Thesis director) / Whipple, Kelin (Committee member) / Barrett, The Honors College (Contributor) / School of Earth and Space Exploration (Contributor) / School of Molecular Sciences (Contributor)
Created2022-05