This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.

Displaying 1 - 7 of 7
Filtering by

Clear all filters

156944-Thumbnail Image.png
Description
Neural interfacing applications have advanced in complexity, with needs for increasingly high degrees of freedom in prosthetic device control, sharper discrimination in sensory percepts in bidirectional interfaces, and more precise localization of functional connectivity in the brain. As such, there is a growing need for reliable neurophysiological recordings at a

Neural interfacing applications have advanced in complexity, with needs for increasingly high degrees of freedom in prosthetic device control, sharper discrimination in sensory percepts in bidirectional interfaces, and more precise localization of functional connectivity in the brain. As such, there is a growing need for reliable neurophysiological recordings at a fine spatial scale matching that of cortical columnar processing. Penetrating microelectrodes provide localization sufficient to isolate action potential (AP) waveforms, but often suffer from recorded signal deterioration linked to foreign body response. Micro-Electrocorticography (μECoG) surface electrodes elicit lower foreign body response and show greater chronic stability of recorded signals, though they typically lack the signal localization necessary to isolate individual APs. This dissertation validates the recording capacity of a novel, flexible, large area μECoG array with bilayer routing in a feline implant, and explores the ability of conventional μECoG arrays to detect features of neuronal activity in a very high frequency band associated with AP waveforms.

Recordings from both layers of the flexible μECoG array showed frequency features typical of cortical local field potentials (LFP) and were shown to be stable in amplitude over time. Recordings from both layers also showed consistent, frequency-dependent modulation after induction of general anesthesia, with large increases in beta and gamma band and decreases in theta band observed over three experiments. Recordings from conventional μECoG arrays over human cortex showed robust modulation in a high frequency (250-2000 Hz) band upon production of spoken words. Modulation in this band was used to predict spoken words with over 90% accuracy. Basal Ganglia neuronal AP firing was also shown to significantly correlate with various cortical μECoG recordings in this frequency band. Results indicate that μECoG surface electrodes may detect high frequency neuronal activity potentially associated with AP firing, a source of information previously unutilized by these devices.
ContributorsBarton, Cody David (Author) / Greger, Bradley (Thesis advisor, Committee member) / Santello, Marco (Committee member) / Buneo, Christopher (Committee member) / Graudejus, Oliver (Committee member) / Artemiadis, Panagiotis (Committee member) / Arizona State University (Publisher)
Created2018
153632-Thumbnail Image.png
Description
Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and

Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes.

A minimally invasive, low-cost epidural intracranial pressure monitoring system is developed for this purpose, using a commercial pressure transducer available for biomedical applications. The system is composed of a pressure transducer, sensing cup, electronics, and data acquisition system. The pressure transducer is a microelectromechanical system (MEMS)-based die that works on piezoresistive phenomenon with dielectric isolation for direct contact with fluids.

The developed system was bench tested and verified in an animal model to confirm the efficacy of the system for intracranial pressure monitoring. The system has a 0.1 mmHg accuracy and a 2% error for the 0-10 mmHg range, with resolution of 0.01 mmHg. This system serves as a minimally invasive (2 mm burr hole) epidural ICP monitor, which could augment existing ECoG electrode arrays, to simultaneously measure intracranial pressure along with the neural signals.

This device could also be employed with brain implants that causes elevation in ICP due to tissue - implant interaction often leading to edema. This research explores the concept and feasibility for integrating the sensing component directly on to the ECoG electrode arrays.
ContributorsSampath Kumaran, Ranjani (Author) / Christen, Jennifer Blain (Thesis advisor) / Tillery, Stephen Helms (Committee member) / Greger, Bradley (Committee member) / Arizona State University (Publisher)
Created2015
155813-Thumbnail Image.png
Description
Prosthetic users abandon devices due to difficulties performing tasks without proper graded or interpretable feedback. The inability to adequately detect and correct error of the device leads to failure and frustration. In advanced prostheses, peripheral nerve stimulation can be used to deliver sensations, but standard schemes used in sensorized

Prosthetic users abandon devices due to difficulties performing tasks without proper graded or interpretable feedback. The inability to adequately detect and correct error of the device leads to failure and frustration. In advanced prostheses, peripheral nerve stimulation can be used to deliver sensations, but standard schemes used in sensorized prosthetic systems induce percepts inconsistent with natural sensations, providing limited benefit. Recent uses of time varying stimulation strategies appear to produce more practical sensations, but without a clear path to pursue improvements. This dissertation examines the use of physiologically based stimulation strategies to elicit sensations that are more readily interpretable. A psychophysical experiment designed to investigate sensitivities to the discrimination of perturbation direction within precision grip suggests that perception is biomechanically referenced: increased sensitivities along the ulnar-radial axis align with potential anisotropic deformation of the finger pad, indicating somatosensation uses internal information rather than environmental. Contact-site and direction dependent deformation of the finger pad activates complimentary fast adapting and slow adapting mechanoreceptors, exhibiting parallel activity of the two associate temporal patterns: static and dynamic. The spectrum of temporal activity seen in somatosensory cortex can be explained by a combined representation of these distinct response dynamics, a phenomenon referred in this dissertation to “biphasic representation.” In a reach-to-precision-grasp task, neurons in somatosensory cortex were found to possess biphasic firing patterns in their responses to texture, orientation, and movement. Sensitivities seem to align with variable deformation and mechanoreceptor activity: movement and smooth texture responses align with potential fast adapting activation, non-movement and coarse texture responses align with potential increased slow adapting activation, and responses to orientation are conceptually consistent with coding of tangential load. Using evidence of biphasic representations’ association with perceptual priorities, gamma band phase locking is used to compare responses to peripheral nerve stimulation patterns and mechanical stimulation. Vibrotactile and punctate mechanical stimuli are used to represent the practical and impractical percepts commonly observed in peripheral nerve stimulation feedback. Standard patterns of constant parameters closely mimic impractical vibrotactile stimulation while biphasic patterns better mimic punctate stimulation and provide a platform to investigate intragrip dynamics representing contextual activation.
ContributorsTanner, Justin Cody (Author) / Helms Tillery, Stephen I (Thesis advisor) / Santos, Veronica J (Committee member) / Santello, Marco (Committee member) / Greger, Bradley (Committee member) / Buneo, Christopher A (Committee member) / Arizona State University (Publisher)
Created2017
187872-Thumbnail Image.png
Description
Multisensory integration is the process by which information from different sensory modalities is integrated by the nervous system. This process is important not only from a basic science perspective but also for translational reasons, e.g., for the development of closed-loop neural prosthetic systems. A mixed virtual reality platform was developed

Multisensory integration is the process by which information from different sensory modalities is integrated by the nervous system. This process is important not only from a basic science perspective but also for translational reasons, e.g., for the development of closed-loop neural prosthetic systems. A mixed virtual reality platform was developed to study the neural mechanisms of multisensory integration for the upper limb during motor planning. The platform allows for selection of different arms and manipulation of the locations of physical and virtual target cues in the environment. The system was tested with two non-human primates (NHP) trained to reach to multiple virtual targets. Arm kinematic data as well as neural spiking data from primary motor (M1) and dorsal premotor cortex (PMd) were collected. The task involved manipulating visual information about initial arm position by rendering the virtual avatar arm in either its actual position (veridical (V) condition) or in a different shifted (e.g., small vs large shifts) position (perturbed (P) condition) prior to movement. Tactile feedback was modulated in blocks by placing or removing the physical start cue on the table (tactile (T), and no-tactile (NT) conditions, respectively). Behaviorally, errors in initial movement direction were larger when the physical start cue was absent. Slightly larger directional errors were found in the P condition compared to the V condition for some movement directions. Both effects were consistent with the idea that erroneous or reduced information about initial hand location led to movement direction-dependent reach planning errors. Neural correlates of these behavioral effects were probed using population decoding techniques. For small shifts in the visual position of the arm, no differences in decoding accuracy between the T and NT conditions were observed in either M1 or PMd. However, for larger visual shifts, decoding accuracy decreased in the NT condition, but only in PMd. Thus, activity in PMd, but not M1, may reflect the uncertainty in reach planning that results when sensory cues regarding initial hand position are erroneous or absent.
ContributorsPhataraphruk, Preyaporn Kris (Author) / Buneo, Christopher A (Thesis advisor) / Zhou, Yi (Committee member) / Helms Tillery, Steve (Committee member) / Greger, Bradley (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2023
171934-Thumbnail Image.png
Description
Safety and efficacy of neuromodulation are influenced by abiotic factors like failure of implants, biotic factors like tissue damage, and molecular and cellular mechanisms of neuromodulation. Accelerated lifetime test (ALT) predict lifetime of implants by accelerating failure modes in controlled bench-top conditions. Current ALT models do not capture failure modes

Safety and efficacy of neuromodulation are influenced by abiotic factors like failure of implants, biotic factors like tissue damage, and molecular and cellular mechanisms of neuromodulation. Accelerated lifetime test (ALT) predict lifetime of implants by accelerating failure modes in controlled bench-top conditions. Current ALT models do not capture failure modes involving biological mechanisms. First part of this dissertation is focused on developing ALTs for predicting failure of chronically implanted tungsten stimulation electrodes. Three factors used in ALT are temperature, H2O2 concentration, and amount of charge delivered through electrode to develop a predictive model of lifetime for stimulation electrodes. Second part of this dissertation is focused on developing a novel method for evaluating tissue response to implants and electrical stimulation. Current methods to evaluate tissue damage in the brain require invasive and terminal procedures that have poor clinical translation. I report a novel non-invasive method that sampled peripheral blood monocytes (PBMCs) and used enzyme-linked immunoassay (ELISA) to assess level of glial fibrillary acidic protein (GFAP) expression and fluorescence-activated cell sorting (FACS) to quantify number of GFAP expressing PBMCs. Using this method, I was able to detect and quantify GFAP expression in PBMCs. However, there was no statistically significant difference in GFAP expression between stimulatory and non-stimulatory implants. Final part of this dissertation assessed molecular and cellular mechanisms of non-invasive ultrasound neuromodulation approach. Unlike electrical stimulation, cellular mechanisms of ultrasound-based neuromodulation are not fully known. Final part of this dissertation assessed role of mechanosensitive ion channels and neuronal nitric oxide production in cell cultures under ultrasound excitation. I used fluorescent imaging to quantify expression of nitric oxide in neuronal cell cultures in response to ultrasound stimulation. Results from these experiments indicate that neuronal nitric oxide production increased in response to ultrasound stimulation compared to control and decreased when mechanosensitive ion channels were suppressed. Two novel methods developed in this dissertation enable assessment of lifetime and safety of neuromodulation techniques that use electrical stimulation through implants. The final part of this dissertation concludes that non-invasive ultrasound neuromodulation may be mediated through neuronal nitric oxide even in absence of activation of mechanosensitive ion channels.
ContributorsVoziyanov, Vladislav (Author) / Muthuswamy, Jitendran (Thesis advisor) / Smith, Barbara (Committee member) / Greger, Bradley (Committee member) / Abbas, James (Committee member) / Okandan, Murat (Committee member) / Arizona State University (Publisher)
Created2022
158833-Thumbnail Image.png
Description
Transcranial focused ultrasound (tFUS) is a unique neurostimulation modality with potential to develop into a highly sophisticated and effective tool. Unlike any other noninvasive neurostimulation technique, tFUS has a high spatial resolution (on the order of millimeters) and can penetrate across the skull, deep into the brain. Sub-thermal tFUS has

Transcranial focused ultrasound (tFUS) is a unique neurostimulation modality with potential to develop into a highly sophisticated and effective tool. Unlike any other noninvasive neurostimulation technique, tFUS has a high spatial resolution (on the order of millimeters) and can penetrate across the skull, deep into the brain. Sub-thermal tFUS has been shown to induce changes in EEG and fMRI, as well as perception and mood. This study investigates the possibility of using tFUS to modulate brain networks involved in attention and cognitive control.Three different brain areas linked to saliency, cognitive control, and emotion within the cingulo-opercular network were stimulated with tFUS while subjects performed behavioral paradigms. The first study targeted the dorsal anterior cingulate cortex (dACC), which is associated with performance on cognitive attention tasks, conflict, error, and, emotion. Subjects performed a variant of the Erikson Flanker task in which emotional faces (fear, neutral or scrambled) were displayed in the background as distractors. tFUS significantly reduced the reaction time (RT) delay induced by faces; there were significant differences between tFUS and Sham groups in event related potentials (ERP), event related spectral perturbation (ERSP), conflict and error processing, and heart rate variability (HRV).
The second study used the same behavioral paradigm, but targeted tFUS to the right anterior insula/frontal operculum (aIns/fO). The aIns/fO is implicated in saliency, cognitive control, interoceptive awareness, autonomic function, and emotion. tFUS was found to significantly alter ERP, ERSP, conflict and error processing, and HRV responses.
The third study targeted tFUS to the right inferior frontal gyrus (rIFG), employing the Stop Signal task to study inhibition. tFUS affected ERPs and improved stopping speed. Using network modeling, causal evidence is presented for rIFG influence on subcortical nodes in stopping.
This work provides preliminarily evidence that tFUS can be used to modulate broader network function through a single node, affecting neurophysiological processing, physiologic responses, and behavioral performance. Additionally it can be used as a tool to elucidate network function. These studies suggest tFUS has the potential to affect cognitive function as a clinical tool, and perhaps even enhance wellbeing and expand conscious awareness.
ContributorsFini, Maria Elizabeth (Author) / Tyler, William J (Thesis advisor) / Greger, Bradley (Committee member) / Santello, Marco (Committee member) / Kleim, Jeffrey (Committee member) / Helms Tillery, Stephen (Committee member) / Arizona State University (Publisher)
Created2020
158383-Thumbnail Image.png
Description
Brain micromotion is a phenomenon that arises from basic physiological functions such as respiration (breathing) and vascular pulsation (pumping blood or heart rate). These physiological processes cause small micro displacements of 2-4µm for vascular pulsation and 10-30µm for respiration, in rat models. One problem related to micromotion is the instability

Brain micromotion is a phenomenon that arises from basic physiological functions such as respiration (breathing) and vascular pulsation (pumping blood or heart rate). These physiological processes cause small micro displacements of 2-4µm for vascular pulsation and 10-30µm for respiration, in rat models. One problem related to micromotion is the instability of the probe and its ability to acquire stable neural recordings in chronic studies. It has long been thought the membrane potential (MP) changes due to micromotion in the presence of brain implants were an artefact caused by the implant. Here is shown that intracellular membrane potential changes are a consequence of the activation of mechanosensitive ion channels at the neural interface. A combination of aplysia and rat animal models were used to show activation of mechanosensitive ion channels is occurring during a neural recording. During simulated micromotion of displacements of 50μm and 100μm at a frequency of 1 Hz, showed a change of 8 and 10mV respectively and that the addition of Ethylenediaminetetraacetic acid (EDTA) inhibited the membrane potential changes. The application of EDTA showed a 71% decrease in changes in membrane potential changes due to micromotion. Simulation of breathing using periodic motion of a probe in an Aplysia model showed that there were no membrane potential changes for <1.5kPa and action potentials were observed at >3.1kPa. Drug studies utilizing 5-HT showed an 80% reduction in membrane potentials. To validate the electrophysiological changes due to micromotion in a rat model, a double barrel pipette for simultaneous recording and drug delivery was designed, the drug delivery tip was recessed from the recording tip no greater than 50μm on average. The double barrel pipette using iontophoresis was used to deliver 30 μM of Gadolinium Chloride (Gd3+) into the microenvironment of the cell. Here is shown a significant reduction in membrane potential for n = 13 cells across 4 different rats tested using Gd3+. Membrane potential changes related to breathing and vascular pulsation were reduced between approximately 0.25-2.5 mV for both breathing and heart rate after the addition of Gd3+, a known mechanosensitive ion channel blocker.
ContributorsDuncan, Jonathan Leroy (Author) / Muthuswamy, Jitendran (Thesis advisor) / Greger, Bradley (Committee member) / Sridharan, Arati (Committee member) / Arizona State University (Publisher)
Created2020