This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.

Displaying 1 - 4 of 4
Filtering by

Clear all filters

152249-Thumbnail Image.png
Description
For CFD validation, hypersonic flow fields are simulated and compared with experimental data specifically designed to recreate conditions found by hypersonic vehicles. Simulated flow fields on a cone-ogive with flare at Mach 7.2 are compared with experimental data from NASA Ames Research Center 3.5" hypersonic wind tunnel. A parametric study

For CFD validation, hypersonic flow fields are simulated and compared with experimental data specifically designed to recreate conditions found by hypersonic vehicles. Simulated flow fields on a cone-ogive with flare at Mach 7.2 are compared with experimental data from NASA Ames Research Center 3.5" hypersonic wind tunnel. A parametric study of turbulence models is presented and concludes that the k-kl-omega transition and SST transition turbulence model have the best correlation. Downstream of the flare's shockwave, good correlation is found for all boundary layer profiles, with some slight discrepancies of the static temperature near the surface. Simulated flow fields on a blunt cone with flare above Mach 10 are compared with experimental data from CUBRC LENS hypervelocity shock tunnel. Lack of vibrational non-equilibrium calculations causes discrepancies in heat flux near the leading edge. Temperature profiles, where non-equilibrium effects are dominant, are compared with the dissociation of molecules to show the effects of dissociation on static temperature. Following the validation studies is a parametric analysis of a hypersonic inlet from Mach 6 to 20. Compressor performance is investigated for numerous cowl leading edge locations up to speeds of Mach 10. The variable cowl study showed positive trends in compressor performance parameters for a range of Mach numbers that arise from maximizing the intake of compressed flow. An interesting phenomenon due to the change in shock wave formation for different Mach numbers developed inside the cowl that had a negative influence on the total pressure recovery. Investigation of the hypersonic inlet at different altitudes is performed to study the effects of Reynolds number, and consequently, turbulent viscous effects on compressor performance. Turbulent boundary layer separation was noted as the cause for a change in compressor performance parameters due to a change in Reynolds number. This effect would not be noticeable if laminar flow was assumed. Mach numbers up to 20 are investigated to study the effects of vibrational and chemical non-equilibrium on compressor performance. A direct impact on the trends on the kinetic energy efficiency and compressor efficiency was found due to dissociation.
ContributorsOliden, Daniel (Author) / Lee, Tae-Woo (Thesis advisor) / Peet, Yulia (Committee member) / Huang, Huei-Ping (Committee member) / Arizona State University (Publisher)
Created2013
153410-Thumbnail Image.png
Description
With the ever-increasing demand for high-end services, technological companies have been forced to operate on high performance servers. In addition to the customer services, the company's internal need to store and manage huge amounts of data has also increased their need to invest in High Density Data Centers. As a

With the ever-increasing demand for high-end services, technological companies have been forced to operate on high performance servers. In addition to the customer services, the company's internal need to store and manage huge amounts of data has also increased their need to invest in High Density Data Centers. As a result, the performance to size of the data center has increased tremendously. Most of the consumed power by the servers is emitted as heat. In a High Density Data Center, the power per floor space area is higher compared to the regular data center. Hence the thermal management of this type of data center is relatively complicated.

Because of the very high power emission in a smaller containment, improper maintenance can result in failure of the data center operation in a shorter period. Hence the response time of the cooler to the temperature rise of the servers is very critical. Any delay in response will constantly lead to increased temperature and hence the server's failure.

In this paper, the significance of this delay time is understood by performing CFD simulation on different variants of High Density Modules using ANSYS Fluent. It was found out that the delay was becoming longer as the size of the data center increases. But the overload temperature, ie. the temperature rise beyond the set-point became lower with the increase in data center size. The results were common for both the single-row and the double-row model. The causes of the increased delay are accounted and explained in detail manner in this paper.
ContributorsRamaraj, Dinesh Balaji (Author) / Gupta, Sandeep (Thesis advisor) / Hermann, Marcus (Committee member) / Huang, Huei-Ping (Committee member) / Arizona State University (Publisher)
Created2015
161883-Thumbnail Image.png
Description
Realistic engineering, physical and biological systems are very complex in nature, and their response and performance are governed by multitude of interacting processes. In computational modeling of these systems, the interactive response is most often ignored, and simplifications are made to model one or a few relevant phenomena as opposed

Realistic engineering, physical and biological systems are very complex in nature, and their response and performance are governed by multitude of interacting processes. In computational modeling of these systems, the interactive response is most often ignored, and simplifications are made to model one or a few relevant phenomena as opposed to a complete set of interacting processes due to a complexity of integrative analysis. In this thesis, I will develop new high-order computational approaches that reduce the amount of simplifications and model the full response of a complex system by accounting for the interaction between different physical processes as required for an accurate description of the global system behavior. Specifically, I will develop multi-physics coupling techniques based on spectral-element methods for the simulations of such systems. I focus on three specific applications: fluid-structure interaction, conjugate heat transfer, and modeling of acoustic wave propagation in non-uniform media. Fluid-structure interaction illustrates a complex system between a fluid and a solid, where a movable and deformable structure is surrounded by fluid flow, and its deformation caused by fluid affects the fluid flow interactively. To simulate this system, two coupling schemes are developed: 1) iterative implicit coupling, and 2) explicit coupling based on Robin-Neumann boundary conditions. A comprehensive verification strategy of the developed methodology is presented, including a comparison with benchmark flow solutions, h-, p- and temporal refinement studies. Simulation of a turbulent flow in a channel interacting with a compliant wall is attempted as well. Another problem I consider is when a solid is stationary, but a heat transfer occurs on the fluid-solid interface. To model this problem, a conjugate heat transfer framework is introduced. Validation of the framework, as well as studies of an interior thermal environment in a building regulated by an HVAC system with an on/off control model with precooling and multi-zone precooling strategies are presented. The final part of this thesis is devoted to modeling an interaction of acoustic waves with the fluid flow. The development of a spectral-element methodology for solution of Lighthill’s equation, and its application to a problem of leak detection in water pipes is presented.
ContributorsXu, Yiqin (Author) / Peet, Yulia (Thesis advisor) / Huang, Huei-Ping (Committee member) / Herrmann, Marcus (Committee member) / Adrian, Ronald (Committee member) / Baer, Steven (Committee member) / Arizona State University (Publisher)
Created2021
193358-Thumbnail Image.png
Description
This dissertation investigates the complex dynamics of semi-dilute inertial particles suspended in vortices using the Eulerian-Lagrangian method. The study explores the modulation of flow induced by inertial particles, focusing on the characteristics of a single vortex, instability analysis within particle-laden flows, and the merging process of co-rotating vortices. Simulations reveal

This dissertation investigates the complex dynamics of semi-dilute inertial particles suspended in vortices using the Eulerian-Lagrangian method. The study explores the modulation of flow induced by inertial particles, focusing on the characteristics of a single vortex, instability analysis within particle-laden flows, and the merging process of co-rotating vortices. Simulations reveal a preferential concentration mechanism, where inertial particles cluster around a void fraction bubble, accelerating the decay of the vortex tube. Small-scale clusters, arising from particle-trajectory crossings, induce significant gradients in the fluid vorticity field, contributing to rapid vortex breakdown. Within a specific Stokes number range, increased particle inertia results in faster vortex decay and stronger inhomogeneity in the particle phase. The instability mechanism in particle-laden flows is explored using a Rankine vortex model. Two-way coupling triggers azimuthal perturbations, leading to the breakdown of the vortex structure. Linear Stability Analysis and Two-Fluid modeling demonstrate that the dusty vortex flow exhibits unstable modes, with growth rates increasing with wavenumber. Eulerian-Lagrangian simulations validate these results, showing excellent agreement between computed and predicted growth rates. The dissertation also delves into the co-rotating vortex merger in a semi-dilute dusty flow. For weak inertial effects, merger experiences a delay compared to particle-free vortices. Under moderate inertial conditions, the merger process exhibits repulsion, increased separation, and eventual convective merger stages. Highly inertial particles stretch the vortex core, initiating a merger with an outcome of a particle-free vortex core surrounded by a halo of concentrated particles. In conclusion, the feedback force from the dispersed phase induces instability and significantly influences the dynamics of vortices in particle-laden flows. The findings contribute to a deeper understanding of the intricate interactions between inertial particles and vortical structures.
ContributorsShuai, Shuai (Author) / Kasbaoui, Mohamed Houssem (Thesis advisor) / Herrmann, Marcus (Committee member) / Peet, Yulia (Committee member) / Huang, Huei-Ping (Committee member) / Wang, Zhihua (Committee member) / Arizona State University (Publisher)
Created2024