This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.

Displaying 1 - 1 of 1
Filtering by

Clear all filters

151165-Thumbnail Image.png
Description
Camera calibration has applications in the fields of robotic motion, geographic mapping, semiconductor defect characterization, and many more. This thesis considers camera calibration for the purpose of high accuracy three-dimensional reconstruction when characterizing ball grid arrays within the semiconductor industry. Bouguet's calibration method is used following a set of criteria

Camera calibration has applications in the fields of robotic motion, geographic mapping, semiconductor defect characterization, and many more. This thesis considers camera calibration for the purpose of high accuracy three-dimensional reconstruction when characterizing ball grid arrays within the semiconductor industry. Bouguet's calibration method is used following a set of criteria with the purpose of studying the method's performance according to newly proposed standards. The performance of the camera calibration method is currently measured using standards such as pixel error and computational time. This thesis proposes the use of standard deviation of the intrinsic parameter estimation within a Monte Carlo simulation as a new standard of performance measure. It specifically shows that the standard deviation decreases based on the increased number of images input into the calibration routine. It is also shown that the default thresholds of the non-linear maximum likelihood estimation problem of the calibration method require change in order to improve computational time performance; however, the accuracy lost is negligable even for high accuracy requirements such as ball grid array characterization.
ContributorsStenger, Nickolas Arthur (Author) / Papandreou-Suppappola, Antonia (Thesis advisor) / Kovvali, Narayan (Committee member) / Tepedelenlioğlu, Cihan (Committee member) / Arizona State University (Publisher)
Created2012