ASU Electronic Theses and Dissertations
This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.
In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.
Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.
Filtering by
- Creators: Tamizhmani, Govindasamy
solutions has increased over the years which has led to the rapid expansion of global
markets in renewable energy sources such as solar photovoltaic (PV) technology. Newest
amongst these technologies is the Bifacial PV modules, which harvests incident radiation
from both sides of the module. The overall power generation can be significantly increased
by using these bifacial modules. The purpose of this research is to investigate and maximize
the effect of back reflectors, designed to increase the efficiency of the module by utilizing
the intercell light passing through the module to increase the incident irradiance, on the
energy output using different profiles placed at varied distances from the plane of the array
(POA). The optimum reflector profile and displacement of the reflector from the module
are determined experimentally.
Theoretically, a 60-cell bifacial module can produce 26% additional energy in
comparison to a 48-cell bifacial module due to the 12 excess cells found in the 60-cell
module. It was determined that bifacial modules have the capacity to produce additional
energy when optimized back reflectors are utilized. The inverted U reflector produced
higher energy gain when placed at farther distances from the module, indicating direct
dependent proportionality between the placement distance of the reflector from the module
and the output energy gain. It performed the best out of all current construction geometries
with reflective coatings, generating more than half of the additional energy produced by a
densely-spaced 60-cell benchmark module compared to a sparsely-spaced 48-cell reference
module.ii
A gain of 11 and 14% was recorded on cloudy and sunny days respectively for the
inverted U reflector. This implies a reduction in the additional cells of the 60-cell module
by 50% can produce the same amount of energy of the 60-cell module by a 48-cell module
with an inverted U reflector. The use of the back reflectors does not only affect the
additional energy gain but structural and land costs. Row to row spacing for bifacial
systems(arrays) is reduced nearly by half as the ground height clearance is largely
minimized, thus almost 50% of height constraints for mounting bifacial modules, using
back reflectors resulting in reduced structural costs for mounting of bifacial modules
Part 1 of this thesis investigates the influence of spatial temperature distribution on the accuracy of performance data of photovoltaic (PV) modules in outdoor conditions and provides physical approaches to improve the spatial temperature distribution of the test modules so an accurate performance data can be obtained in the field. Conventionally, during outdoor performance testing, a single thermocouple location is used on the backsheet or back glass of a test module. This study clearly indicates that there is a large spatial temperature difference between various thermocouple locations within a module. Two physical approaches or configurations were experimented to improve the spatial temperature uniformity: thermally insulating the inner and outer surface of the frame; backsheet and inner surface of the frame. All the data were compared with un-insulated conventional configuration. This study was performed in an array setup of six modules under two different preconditioning electrical configurations, Voc and MPPT over several clear sunny days. This investigation concludes that the best temperature uniformity and the most accurate I-V data can be obtained only by thermally insulating the inner and outer frame surfaces or by using the average of four thermocouple temperatures, as specified in IEC 61853-2, without any thermal insulation.
Part 2 of this thesis analyzes the field data obtained from old PV power plants using various statistical techniques to identify the most influential degradation modes on fielded PV modules in two different climates: hot-dry (Arizona); cold-dry (New York). Performance data and visual inspection data of 647 modules fielded in five different power plants were analyzed. Statistical tests including hypothesis testing were carried out to identify the I-V parameter(s) that are affected the most. The affected performance parameters (Isc, Voc, FF and Pmax) were then correlated with the defects to determine the most dominant defect affecting power degradation. Analysis indicates that the cell interconnect discoloration (or solder bond deterioration) is the dominant defect in hot-dry climate leading to series resistance increase and power loss, while encapsulant delamination is being the most dominant defect in cold-dry climate leading to cell mismatch and power loss.
Part 1: Linearity determination in degradation: The electricity output from PV power plants degrades every year. Generally, a system’s life is considered to last for 20-25 years and rate of degradation is commonly assumed as 1% per year. PV degradation can be found out using Performance Ratio (PR), Performance Index (PI) and raw kWh output. The rate of degradation is considered linear for simplicity of calculations. In this thesis, statistical methods are used to check whether systems in Arizona are degrading linearly or not. Time series modeling such as Winters’ method and ARIMA are used to model the data. Winters’ method and Seasonal ARIMA consider the seasonality component and perform well for small data sets of about 10 years. Rate of degradation is found out as linear for all the evaluated systems.
Part 2: Temperature analysis of clean and soiled modules: Soiling and temperature are important parameters in performance of PV modules. In this paper, an analysis is carried out on a soiling station located in Mesa, Arizona. The soiling station consists of 10 different c-Si coupons with tilt angles varying from 0° to 45° with the difference of 5°. These coupons are cut in half, one is cleaned periodically and the other is remained soiled naturally. The analysis involves data worth for 19 months. 6 dry spells in all four seasons within 19 months were analyzed. The temperature difference between a clean module and a soiled module (ΔT) is compared with the soiling loss factor (SLF). The analysis concludes stating in which season a soiled module is hotter or cooler than a clean module.