This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.

Displaying 1 - 3 of 3
Filtering by

Clear all filters

156613-Thumbnail Image.png
Description
This work describes efforts made toward the development of a compact, quantitative fluorescence-based multiplexed detection platform for point-of-care diagnostics. This includes the development of a microfluidic delivery and actuation system for multistep detection assays. Early detection of infectious diseases requires high sensitivity dependent on the precise actuation of fluids.

Methods

This work describes efforts made toward the development of a compact, quantitative fluorescence-based multiplexed detection platform for point-of-care diagnostics. This includes the development of a microfluidic delivery and actuation system for multistep detection assays. Early detection of infectious diseases requires high sensitivity dependent on the precise actuation of fluids.

Methods of fluid actuation were explored to allow delayed delivery of fluidic reagents in multistep detection lateral flow assays (LFAs). Certain hydrophobic materials such as wax were successfully implemented in the LFA with the use of precision dispensed valves. Sublimating materials such as naphthalene were also characterized along with the implementation of a heating system for precision printing of the valves.

Various techniques of blood fractionation were also investigated and this work demonstrates successful blood fractionation in an LFA. The fluid flow of reagents was also characterized and validated with the use of mathematical models and multiphysics modeling software. Lastly intuitive, user-friendly mobile and desktop applications were developed to interface the underlying Arduino software. The work advances the development of a system which successfully integrates all components of fluid separation and delivery along with highly sensitive detection and a user-friendly interface; the system will ultimately provide clinically significant diagnostics in a of point-of-care device.
ContributorsArafa, Hany M (Author) / Blain Christen, Jennifer M (Thesis advisor) / Goryll, Michael (Committee member) / Smith, Barbara (Committee member) / Arizona State University (Publisher)
Created2018
156930-Thumbnail Image.png
Description
Over the past several decades, there has been a growing interest in the use of fluorescent probes in low-cost diagnostic devices for resource-limited environments. This dissertation details the design, development, and deployment of an inexpensive, multiplexed, and quantitative, fluorescence-based lateral flow immunoassay platform, in light of the specific constraints associated

Over the past several decades, there has been a growing interest in the use of fluorescent probes in low-cost diagnostic devices for resource-limited environments. This dissertation details the design, development, and deployment of an inexpensive, multiplexed, and quantitative, fluorescence-based lateral flow immunoassay platform, in light of the specific constraints associated with resource-limited settings.

This effort grew out of the need to develop a highly sensitive, field-deployable platform to be used as a primary screening and early detection tool for serologic biomarkers for the high-risk human papillomavirus (hrHPV) infection. A hrHPV infection is a precursor for developing high-grade cervical intraepithelial neoplasia (CIN 2/3+). Early detection requires high sensitivity and a low limit-of-detection (LOD). To this end, the developed platform (DxArray) takes advantage of the specificity of immunoassays and the selectivity of fluorescence for early disease detection. The long term goal is to improve the quality of life for several hundred million women globally, at risk of being infected with hrHPV.

The developed platform uses fluorescent labels over the gold-standard colorimetric labels in a compact, high-sensitivity lateral flow assay configuration. It is also compatible with POC settings as it substitutes expensive and bulky light sources for LEDs, low-light CMOS cameras, and photomultiplier tubes for photodiodes, in a transillumination architecture, and eliminates the need for expensive focusing/transfer optics. The platform uses high-quality interference filters at less than $1 each, enabling a rugged and robust design suitable for field use.

The limit of detection (LOD) of the developed platform is within an order of magnitude of centralized laboratory diagnostic instruments. It enhances the LOD of absorbance or reflectometric and visual readout lateral flow assays by 2 - 3 orders of magnitude. This system could be applied toward any chemical or bioanalytical procedure that requires a high performance at low-cost.

The knowledge and techniques developed in this effort is relevant to the community of researchers and industry developers looking to deploy inexpensive, quantitative, and highly sensitive diagnostic devices to resource-limited settings.
ContributorsObahiagbon, Uwadiae (Author) / Blain Christen, Jennifer M (Thesis advisor) / Anderson, Karen S (Committee member) / Goryll, Michael (Committee member) / Smith, Barbara S. (Committee member) / Arizona State University (Publisher)
Created2018
171476-Thumbnail Image.png
Description
Portable health diagnostic systems seek to perform medical grade diagnostics in non-ideal environments. This work details a robust fault tolerant portable health diagnostic design implemented in hardware, firmware and software for the detectionof HPV in low-income countries. The device under device under test (DUT) is a fluorescence based lateral flow

Portable health diagnostic systems seek to perform medical grade diagnostics in non-ideal environments. This work details a robust fault tolerant portable health diagnostic design implemented in hardware, firmware and software for the detectionof HPV in low-income countries. The device under device under test (DUT) is a fluorescence based lateral flow assay (LFA) point-of-care (POC) device. This work’s contributions are: firmware and software development, calibration routine implementation, device performance characterization and a proposed method of in-software fault detection. Firmware was refactored from the original implementation of the POC fluorescence reader to expose an application programming interface (API) via USB. Companion software available for desktop environments (Windows, Mac and Linux) was created to interface with this firmware API and conduct macro level routines to request and receive fluorescence data while presenting a user-friendly interface to clinical technicians. Lastly, an environmental chamber was constructed to conduct sequential diagnostic reads in order to observe sensor drift and other deviations that might present themselves in real-world usage. The results from these evaluations show a standard deviation of less than 1% in fluorescence readings in nominal temperature environments (approx. 25C) suggesting that this system will have a favorable signal-to-noise (SNR) ratio in such a setting. In non-ideal over heated environments (≥38C), the evaluation results showed performance degradation with standard deviations as large as 15%.
ContributorsLue Sang, Christopher David (Author) / Blain Christen, Jennifer M (Thesis advisor) / Ozev, Sule (Committee member) / Goryll, Michael (Committee member) / Raupp, Gregory (Committee member) / Arizona State University (Publisher)
Created2022