This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.

In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.

Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.

Displaying 1 - 2 of 2
Filtering by

Clear all filters

153834-Thumbnail Image.png
Description
First, in a large-scale structure, a 3-D CFD model was built to simulate flow and temperature distributions. The flow patterns and temperature distributions are characterized and validated through spot measurements. The detailed understanding of them then allows for optimization of the HVAC configuration because identification of the problematic flow patterns

First, in a large-scale structure, a 3-D CFD model was built to simulate flow and temperature distributions. The flow patterns and temperature distributions are characterized and validated through spot measurements. The detailed understanding of them then allows for optimization of the HVAC configuration because identification of the problematic flow patterns and temperature mis-distributions leads to some corrective measures. Second, an appropriate form of the viscous dissipation term in the integral form of the conservation equation was considered, and the effects of momentum terms on the computed drop size in pressure-atomized sprays were examined. The Sauter mean diameter (SMD) calculated in this manner agrees well with experimental data of the drop velocities and sizes. Using the suggested equation with the revised treatment of liquid momentum setup, injection parameters can be directly input to the system of equations. Thus, this approach is capable of incorporating the effects of injection parameters for further considerations of the drop and velocity distributions under a wide range of spray geometry and injection conditions. Lastly, groundwater level estimation was investigated using compressed sensing (CS). To satisfy a general property of CS, a random measurement matrix was used, the groundwater network was constructed, and finally the l-1 optimization was run. Through several validation tests, correct estimation of groundwater level by CS was shown. Using this setup, decreasing trends in groundwater level in the southwestern US was shown. The suggested method is effective in that the total measurements of registered wells can be reduced down by approximately 42 %, sparse data can be visualized and a possible approach for groundwater management during extreme weather changes, e.g. in California, was demonstrated.
ContributorsLee, Joon Young (Author) / Lee, Taewoo (Thesis advisor) / Huang, Huei-Ping (Committee member) / Lopez, Juan (Committee member) / Phelan, Patrick (Committee member) / Chen, Kangping (Committee member) / Arizona State University (Publisher)
Created2015
155081-Thumbnail Image.png
Description
ABSTRACT

A large fraction of the total energy consumption in the world comes from heating and cooling of buildings. Improving the energy efficiency of buildings to reduce the needs of seasonal heating and cooling is one of the major challenges in sustainable development. In general, the energy efficiency depends

ABSTRACT

A large fraction of the total energy consumption in the world comes from heating and cooling of buildings. Improving the energy efficiency of buildings to reduce the needs of seasonal heating and cooling is one of the major challenges in sustainable development. In general, the energy efficiency depends on the geometry and material of the buildings. To explore a framework for accurately assessing this dependence, detailed 3-D thermofluid simulations are performed by systematically sweeping the parameter space spanned by four parameters: the size of building, thickness and material of wall, and fractional size of window. The simulations incorporate realistic boundary conditions of diurnally-varying temperatures from observation, and the effect of fluid flow with explicit thermal convection inside the building. The outcome of the numerical simulations is synthesized into a simple map of an index of energy efficiency in the parameter space which can be used by stakeholders to quick look-up the energy efficiency of a proposed design of a building before its construction. Although this study only considers a special prototype of buildings, the framework developed in this work can potentially be used for a wide range of buildings and applications.
ContributorsJain, Gaurav (Author) / Huang, Huei-Ping (Thesis advisor) / Ren, Yi (Committee member) / Oswald, Jay (Committee member) / Arizona State University (Publisher)
Created2016