Filtering by
- Resource Type: Text
Grading schemes for breast cancer diagnosis are predominantly based on pathologists' qualitative assessment of altered nuclear structure from 2D brightfield microscopy images. However, cells are three-dimensional (3D) objects with features that are inherently 3D and thus poorly characterized in 2D. Our goal is to quantitatively characterize nuclear structure in 3D, assess its variation with malignancy, and investigate whether such variation correlates with standard nuclear grading criteria.
Methodology
We applied micro-optical computed tomographic imaging and automated 3D nuclear morphometry to quantify and compare morphological variations between human cell lines derived from normal, benign fibrocystic or malignant breast epithelium. To reproduce the appearance and contrast in clinical cytopathology images, we stained cells with hematoxylin and eosin and obtained 3D images of 150 individual stained cells of each cell type at sub-micron, isotropic resolution. Applying volumetric image analyses, we computed 42 3D morphological and textural descriptors of cellular and nuclear structure.
Principal Findings
We observed four distinct nuclear shape categories, the predominant being a mushroom cap shape. Cell and nuclear volumes increased from normal to fibrocystic to metastatic type, but there was little difference in the volume ratio of nucleus to cytoplasm (N/C ratio) between the lines. Abnormal cell nuclei had more nucleoli, markedly higher density and clumpier chromatin organization compared to normal. Nuclei of non-tumorigenic, fibrocystic cells exhibited larger textural variations than metastatic cell nuclei. At p<0.0025 by ANOVA and Kruskal-Wallis tests, 90% of our computed descriptors statistically differentiated control from abnormal cell populations, but only 69% of these features statistically differentiated the fibrocystic from the metastatic cell populations.
Conclusions
Our results provide a new perspective on nuclear structure variations associated with malignancy and point to the value of automated quantitative 3D nuclear morphometry as an objective tool to enable development of sensitive and specific nuclear grade classification in breast cancer diagnosis.
The coffee cup system can be simplified and modeled by a cart-and-pendulum system. Bazzi et al. and Maurice et al. present two different cart-and-pendulum systems to represent the coffee cup system [1],[2]. The purpose of this project was to build upon these systems and to gain a better understanding of the coffee cup system and to determine where chaos existed within the system. The honors thesis team first worked with their senior design group to develop a mathematical model for the cart-and-pendulum system based on the Bazzi and Maurice papers [1],[2]. This system was analyzed and then built upon by the honors thesis team to build a cart-and-two-pendulum model to represent the coffee cup system more accurately.
Analysis of the single pendulum model showed that there exists a low frequency region where the pendulum and the cart remain in phase with each other and a high frequency region where the cart and pendulum have a π phase difference between them. The transition point of the low and high frequency region is determined by the resonant frequency of the pendulum. The analysis of the two-pendulum system also confirmed this result and revealed that differences in length between the pendulum cause the pendulums to transition to the high frequency regions at separate frequency. The pendulums have different resonance frequencies and transition into the high frequency region based on their own resonant frequency. This causes a range of frequencies where the pendulums are out of phase from each other. After both pendulums have transitioned, they remain in phase with each other and out of phase from the cart.
However, if the length of the pendulum is decreased too much, the system starts to exhibit chaotic behavior. The short pendulum starts to act in a chaotic manner and the phase relationship between the pendulums and the carts is no longer maintained. Since the pendulum length represents the distance between the particle of coffee and the top of the cup, this implies that coffee near the top of the cup would cause the system to act chaotically. Further analysis would be needed to determine the reason why the length affects the system in this way.
In this research, I surveyed existing methods of characterizing Epilepsy from Electroencephalogram (EEG) data, including the Random Forest algorithm, which was claimed by many researchers to be the most effective at detecting epileptic seizures [7]. I observed that although many papers claimed a detection of >99% using Random Forest, it was not specified “when” the detection was declared within the 23.6 second interval of the seizure event. In this research, I created a time-series procedure to detect the seizure as early as possible within the 23.6 second epileptic seizure window and found that the detection is effective (> 92%) as early as the first few seconds of the epileptic episode. I intend to use this research as a stepping stone towards my upcoming Masters thesis research where I plan to expand the time-series detection mechanism to the pre-ictal stage, which will require a different dataset.