Matching Items (57)
148082-Thumbnail Image.png
Description

There are many challenges in designing neuroprostheses and one of them is to maintain proper axon selectivity in all situations. This project is based on an electrode that is implanted into a fascicle in a peripheral nerve and used to provide tactile sensory feedback of a prosthetic arm. This fascicle

There are many challenges in designing neuroprostheses and one of them is to maintain proper axon selectivity in all situations. This project is based on an electrode that is implanted into a fascicle in a peripheral nerve and used to provide tactile sensory feedback of a prosthetic arm. This fascicle can undergo mechanical deformation during every day motion. This work aims to characterize the effect of fascicle deformation on axon selectivity and recruitment when electrically stimulated using hybrid modeling. The main framework consists of combining finite element modeling (FEM) and simulation environment NEURON. A suite of programs was developed to first populate a fascicle with axons followed by deforming the fascicle and rearranging axons accordingly. A model of the fascicle with an implanted electrode is simulated to find the electrical potential profile through FEM. The potential profile is then used to compare which axons are activated in the two conformations of the fascicle using NERUON.

ContributorsDileep, Devika (Author) / Abbas, James (Thesis director) / Sadleir, Rosalind (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
152241-Thumbnail Image.png
Description
The efficacy of deep brain stimulation (DBS) in Parkinson's disease (PD) has been convincingly demonstrated in studies that compare motor performance with and without stimulation, but characterization of performance at intermediate stimulation amplitudes has been limited. This study investigated the effects of changing DBS amplitude in order to assess dose-response

The efficacy of deep brain stimulation (DBS) in Parkinson's disease (PD) has been convincingly demonstrated in studies that compare motor performance with and without stimulation, but characterization of performance at intermediate stimulation amplitudes has been limited. This study investigated the effects of changing DBS amplitude in order to assess dose-response characteristics, inter-subject variability, consistency of effect across outcome measures, and day-to-day variability. Eight subjects with PD and bilateral DBS systems were evaluated at their clinically determined stimulation (CDS) and at three reduced amplitude conditions: approximately 70%, 30%, and 0% of the CDS (MOD, LOW, and OFF, respectively). Overall symptom severity and performance on a battery of motor tasks - gait, postural control, single-joint flexion-extension, postural tremor, and tapping - were assessed at each condition using the motor section of the Unified Parkinson's Disease Rating Scale (UPDRS-III) and quantitative measures. Data were analyzed to determine whether subjects demonstrated a threshold response (one decrement in stimulation resulted in ≥ 70% of the maximum change) or a graded response to reduced stimulation. Day-to-day variability was assessed using the CDS data from the three testing sessions. Although the cohort as a whole demonstrated a graded response on several measures, there was high variability across subjects, with subsets exhibiting graded, threshold, or minimal responses. Some subjects experienced greater variability in their CDS performance across the three days than the change induced by reducing stimulation. For several tasks, a subset of subjects exhibited improved performance at one or more of the reduced conditions. Reducing stimulation did not affect all subjects equally, nor did it uniformly affect each subject's performance across tasks. These results indicate that altered recruitment of neural structures can differentially affect motor capabilities and demonstrate the need for clinical consideration of the effects on multiple symptoms across several days when selecting DBS parameters.
ContributorsConovaloff, Alison (Author) / Abbas, James (Thesis advisor) / Krishnamurthi, Narayanan (Committee member) / Mahant, Padma (Committee member) / Jung, Ranu (Committee member) / Helms Tillery, Stephen (Committee member) / Arizona State University (Publisher)
Created2013
152400-Thumbnail Image.png
Description
Advances in implantable MEMS technology has made possible adaptive micro-robotic implants that can track and record from single neurons in the brain. Development of autonomous neural interfaces opens up exciting possibilities of micro-robots performing standard electrophysiological techniques that would previously take researchers several hundred hours to train and achieve the

Advances in implantable MEMS technology has made possible adaptive micro-robotic implants that can track and record from single neurons in the brain. Development of autonomous neural interfaces opens up exciting possibilities of micro-robots performing standard electrophysiological techniques that would previously take researchers several hundred hours to train and achieve the desired skill level. It would result in more reliable and adaptive neural interfaces that could record optimal neural activity 24/7 with high fidelity signals, high yield and increased throughput. The main contribution here is validating adaptive strategies to overcome challenges in autonomous navigation of microelectrodes inside the brain. The following issues pose significant challenges as brain tissue is both functionally and structurally dynamic: a) time varying mechanical properties of the brain tissue-microelectrode interface due to the hyperelastic, viscoelastic nature of brain tissue b) non-stationarities in the neural signal caused by mechanical and physiological events in the interface and c) the lack of visual feedback of microelectrode position in brain tissue. A closed loop control algorithm is proposed here for autonomous navigation of microelectrodes in brain tissue while optimizing the signal-to-noise ratio of multi-unit neural recordings. The algorithm incorporates a quantitative understanding of constitutive mechanical properties of soft viscoelastic tissue like the brain and is guided by models that predict stresses developed in brain tissue during movement of the microelectrode. An optimal movement strategy is developed that achieves precise positioning of microelectrodes in the brain by minimizing the stresses developed in the surrounding tissue during navigation and maximizing the speed of movement. Results of testing the closed-loop control paradigm in short-term rodent experiments validated that it was possible to achieve a consistently high quality SNR throughout the duration of the experiment. At the systems level, new generation of MEMS actuators for movable microelectrode array are characterized and the MEMS device operation parameters are optimized for improved performance and reliability. Further, recommendations for packaging to minimize the form factor of the implant; design of device mounting and implantation techniques of MEMS microelectrode array to enhance the longevity of the implant are also included in a top-down approach to achieve a reliable brain interface.
ContributorsAnand, Sindhu (Author) / Muthuswamy, Jitendran (Thesis advisor) / Tillery, Stephen H (Committee member) / Buneo, Christopher (Committee member) / Abbas, James (Committee member) / Tsakalis, Konstantinos (Committee member) / Arizona State University (Publisher)
Created2013
151271-Thumbnail Image.png
Description
Humans moving in the environment must frequently change walking speed and direction to negotiate obstacles and maintain balance. Maneuverability and stability requirements account for a significant part of daily life. While constant-average-velocity (CAV) human locomotion in walking and running has been studied extensively unsteady locomotion has received far less attention.

Humans moving in the environment must frequently change walking speed and direction to negotiate obstacles and maintain balance. Maneuverability and stability requirements account for a significant part of daily life. While constant-average-velocity (CAV) human locomotion in walking and running has been studied extensively unsteady locomotion has received far less attention. Although some studies have described the biomechanics and neurophysiology of maneuvers, the underlying mechanisms that humans employ to control unsteady running are still not clear. My dissertation research investigated some of the biomechanical and behavioral strategies used for stable unsteady locomotion. First, I studied the behavioral level control of human sagittal plane running. I tested whether humans could control running using strategies consistent with simple and independent control laws that have been successfully used to control monopod robots. I found that humans use strategies that are consistent with the distributed feedback control strategies used by bouncing robots. Humans changed leg force rather than stance duration to control center of mass (COM) height. Humans adjusted foot placement relative to a "neutral point" to change running speed increment between consecutive flight phases, i.e. a "pogo-stick" rather than a "unicycle" strategy was adopted to change running speed. Body pitch angle was correlated by hip moments if a proportional-derivative relationship with time lags corresponding to pre-programmed reaction (87 ± 19 ms) was assumed. To better understand the mechanisms of performing successful maneuvers, I studied the functions of joints in the lower extremities to control COM speed and height. I found that during stance, the hip functioned as a power generator to change speed. The ankle switched between roles as a damper and torsional spring to contributing both to speed and elevation changes. The knee facilitated both speed and elevation control by absorbing mechanical energy, although its contribution was less than hip or ankle. Finally, I studied human turning in the horizontal plane. I used a morphological perturbation (increased body rotational inertia) to elicit compensational strategies used to control sidestep cutting turns. Humans use changes to initial body angular speed and body pre-rotation to prevent changes in braking forces.
ContributorsQiao, Mu, 1981- (Author) / Jindrich, Devin L (Thesis advisor) / Dounskaia, Natalia (Committee member) / Abbas, James (Committee member) / Hinrichs, Richard (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2012
151099-Thumbnail Image.png
Description
Spinal cord injury (SCI) disrupts the communication between supraspinal circuits and spinal circuits distal to the injury. This disruption causes changes in the motor abilities of the affected individual, but it can also be used as an opportunity to study motor control in the absence or limited presence of control

Spinal cord injury (SCI) disrupts the communication between supraspinal circuits and spinal circuits distal to the injury. This disruption causes changes in the motor abilities of the affected individual, but it can also be used as an opportunity to study motor control in the absence or limited presence of control from the brain. In the case of incomplete paraplegia, locomotion is impaired and often results in increased incidence of foot drag and decreased postural stability after injury. The overall goal of this work is to understand how changes in kinematics of movement and neural control of muscles effect locomotor coordination following SCI. Toward this end, we examined musculoskeletal parameters and kinematics of gait in rats with and without incomplete SCI (iSCI) and used an empirically developed computational model to test related hypotheses. The first study tested the hypothesis that iSCI causes a decrease in locomotor and joint angle movement complexity. A rat model was used to measure musculoskeletal properties and gait kinematics following mild iSCI. The data indicated joint-specific changes in kinematics in the absence of measurable muscle atrophy, particularly at the ankle as a result of the injury. Kinematic changes manifested as a decrease in complexity of ankle motion as indicated by measures of permutation entropy. In the second study, a new 2-dimensional computational model of the rat ankle combining forward and inverse dynamics was developed using the previously collected data. This model was used to test the hypothesis that altered coordination of flexor and extensor muscles (specifically alteration in burst shape and timing) acting at the ankle joint could be responsible for increases in incidence of foot drag following injury. Simulation results suggest a time course for changes in neural control following injury that begins with foot drag and decreased delay between antagonistic muscle activations. Following this, beneficial adaptations in muscle activation profile and ankle kinematics counteract the decreased delay to allow foot swing. In both studies, small changes in neural control caused large changes in behavior, particularly at the ankle. Future work will further examine the role of neural control of hindlimb in rat locomotion following iSCI.
ContributorsHillen, Brian (Author) / Jung, Ranu (Thesis advisor) / Abbas, James (Committee member) / Muthuswamy, Jit (Committee member) / Jindrich, Devin (Committee member) / Yamaguchi, Gary (Committee member) / Arizona State University (Publisher)
Created2012
137218-Thumbnail Image.png
Description
The effect of three different drug modulators on the electrophysiological response of Aplysia neurons was observed through the use of extracellular and intracellular recordings. Extracellular recordings captured the effects of magnesium chloride and glutamate at a variety of concentrations for each. Intracellular recordings displayed the effects of magnesium chloride, glutamate,

The effect of three different drug modulators on the electrophysiological response of Aplysia neurons was observed through the use of extracellular and intracellular recordings. Extracellular recordings captured the effects of magnesium chloride and glutamate at a variety of concentrations for each. Intracellular recordings displayed the effects of magnesium chloride, glutamate, and GABA for two concentrations each. For extracellular recordings, the average firing rate, average peak-to-peak voltage, average SNR, and sorted units were considered. For intracellular recordings, average firing rate, average peak voltage, and average resting potential were considered. Significance of data could not be determined using statistical analysis due to having a sample size of 1 for every experiment.
ContributorsEyster, Kyle (Co-author) / Moore, Amanda (Co-author) / Muthuswamy, Jitendran (Thesis director) / Sadleir, Rosalind (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
132508-Thumbnail Image.png
Description
Electrical stimulation can be used to activate peripheral nerve fibers to restore sensation to individuals with amputation and the technique is also being investigated as a means of treating a wide range of diseases. Longitudinal intrafascicular electrodes (LIFEs) are one of several types of electrodes that have been used

Electrical stimulation can be used to activate peripheral nerve fibers to restore sensation to individuals with amputation and the technique is also being investigated as a means of treating a wide range of diseases. Longitudinal intrafascicular electrodes (LIFEs) are one of several types of electrodes that have been used to activate peripheral nerves. LIFEs can be used to activate small groups of fibers within a peripheral nerve fascicle, but the degree of their selectivity is uncertain. To investigate the effects of intrafascicular stimulation on nerve fiber activation, a mathematical, conductance-based model of an axon drawn from the literature was implemented and used to simulate the firing response of sensory nerve fibers in the presence of an applied monopolar electric field. Several axons were simulated to represent axons of different size, conductivity, spatial composition and location with respect to the electrode. Electric field profiles produced by pulses of different pulse widths and pulse amplitudes were created. Each fiber was placed within each resulting electric field and the firing threshold was determined. The effects of changes in pulse width, pulse amplitude, and distance on firing patterns were shown; all of these results were consistent with published experimental findings. The models showed lower firing threshold for smaller fibers than larger fibers and for fibers that were farther from the stimulating electrode than those that were closer. Firing threshold was also lower for stimuli of greater pulse width. Analysis of axon recruitment upon increases in pulse amplitude showed that the effects of fiber distance may be more pronounced than the effects of fiber size. This model can serve as a basis for further development to more accurately represent the effects of LIFEs and eventually may assist in the design of stimulation paradigms and waveforms to improve selectivity of axon activation when using LIFEs.
ContributorsSira, Alarmel (Author) / Abbas, James (Thesis director) / Crook, Sharon (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2019-05
133398-Thumbnail Image.png
Description
Skin and muscle receptors in the leg and foot provide able-bodied humans with force and position information that is crucial for balance and movement control. In lower-limb amputees however, this vital information is either missing or incomplete. Amputees typically compensate for the loss of sensory information by relying on haptic

Skin and muscle receptors in the leg and foot provide able-bodied humans with force and position information that is crucial for balance and movement control. In lower-limb amputees however, this vital information is either missing or incomplete. Amputees typically compensate for the loss of sensory information by relying on haptic feedback from the stump-socket interface. Unfortunately, this is not an adequate substitute. Areas of the stump that directly interface with the socket are also prone to painful irritation, which further degrades haptic feedback. The lack of somatosensory feedback from prosthetic legs causes several problems for lower-limb amputees. Previous studies have established that the lack of adequate sensory feedback from prosthetic limbs contributes to poor balance and abnormal gait kinematics. These improper gait kinematics can, in turn, lead to the development of musculoskeletal diseases. Finally, the absence of sensory information has been shown to lead to steeper learning curves and increased rehabilitation times, which hampers amputees from recovering from the trauma. In this study, a novel haptic feedback system for lower-limb amputees was develped, and studies were performed to verify that information presented was sufficiently accurate and precise in comparison to a Bertec 4060-NC force plate. The prototype device consisted of a sensorized insole, a belt-mounted microcontroller, and a linear array of four vibrotactile motors worn on the thigh. The prototype worked by calculating the center of pressure in the anteroposterior plane, and applying a time-discrete vibrotactile stimulus based on the location of the center of pressure.
ContributorsKaplan, Gabriel Benjamin (Author) / Abbas, James (Thesis director) / McDaniel, Troy (Committee member) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
133348-Thumbnail Image.png
Description
The inception of the human-powered water pump began during my trip to Maasailand in Kenya over the Summer of 2017. Being one of the few Broadening the Reach of Engineering through Community Engagement (BRECE) Scholars at Arizona State University, I was given the opportunity to join Prescott College (PC) on

The inception of the human-powered water pump began during my trip to Maasailand in Kenya over the Summer of 2017. Being one of the few Broadening the Reach of Engineering through Community Engagement (BRECE) Scholars at Arizona State University, I was given the opportunity to join Prescott College (PC) on their annual trip to the Maasai Education, Research, and Conservation (MERC) Institute in rural Kenya. The ASU BRECE scholars that choose to travel were asked to collaborate with the local Maasai community to help develop functional and sustainable engineering solutions to problems identified alongside community members using rudimentary technology and tools that were available in this resource-constrained setting. This initiative evolved into multiple projects from the installation of GravityLights (a local invention that powers LEDs with falling sandbags), the construction/installation of smokeless stoves, and development of a much-needed solution to move water from the rainwater collection tanks around camp to other locations. This last project listed was prototyped once in camp, and this report details subsequent iterations of this human-powered pump.
ContributorsMiller, Miles Edward (Author) / Henderson, Mark (Thesis director) / Abbas, James (Committee member) / Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
133785-Thumbnail Image.png
Description
This study was conducted to examine the potential effects of exercise training on partial spinal cord injury on locomotor recovery in juvenile rats. Three groups were tested, where three female Long-Evans rats 10-12 weeks of age were studied for their locomotion. All animals underwent a T8-T9 laminectomy and two of

This study was conducted to examine the potential effects of exercise training on partial spinal cord injury on locomotor recovery in juvenile rats. Three groups were tested, where three female Long-Evans rats 10-12 weeks of age were studied for their locomotion. All animals underwent a T8-T9 laminectomy and two of the three in each group received a dorsal, partial spinal cord injury. Locomotion was then analyzed every week, over 8-10 weeks. One of the two injured animals was given open access to a wheel after 2 weeks for voluntary exercise training. The results of this study suggested that injured animals displayed more irregular stepping patterns, larger hindlimb bases of support, greater and more variable interpaw distances, slower hindlimb speed, and increased dependency of swing-phase duty cycle on hindlimb speed. Trained animals displayed quicker recovery of stepping patterns, stepping of the hindpaw in relation to the preceding ipsilateral forepaw, and higher swing-duty cycle dependency on hindlimb speed in comparison to injured animals that did not receive exercise training. Due to a small sample size, there was a large amount of variation between individual animals in most parameters. These results are considered to be potential effects that may be seen in further study with a larger sample size. The research team will continue the research project to examine changes in neural pathways in the spinal cord and the effects of exercise on recovery after injury.
ContributorsSleem, Tamara Hatem (Author) / Abbas, James (Thesis director) / Hamm, Thomas (Committee member) / School of Human Evolution and Social Change (Contributor) / Department of Psychology (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05