Matching Items (205)
156905-Thumbnail Image.png
Description
There is an increasing demand for fully integrated point-of-load (POL) isolated DC-DC converters that can provide an isolation barrier between the primary and the secondary side, while delivering a low ripple, low noise regulated voltage at their isolated sides to a high dynamic range, sensitive mixed signal devices, such as

There is an increasing demand for fully integrated point-of-load (POL) isolated DC-DC converters that can provide an isolation barrier between the primary and the secondary side, while delivering a low ripple, low noise regulated voltage at their isolated sides to a high dynamic range, sensitive mixed signal devices, such as sensors, current-shunt-monitors and ADCs. For these applications, smaller system size and integration level is important because the whole system may need to fit to limited space. Traditional methods for providing isolated power are discrete solutions using bulky transformers. Miniaturization of isolated POL regulators is becoming highly desirable for low power applications.

A fully integrated, low noise isolated point-of-load DC-DC converter for supply regulation of high dynamic range analog and mixed signal sensor signal-chains is presented. The isolated DC-DC converter utilizes an integrated planar air-core micro-transformer as a coupled resonator and isolation barrier and enables direct connection of low-voltage mixed signal circuits to higher supply rails. The air core transformer is driven at its primary resonant frequency of 100 MHz to achieve maximum power transfer. A mixed-signal perturb-and-observe based frequency search algorithm is developed to improve maximum power transfer efficiency by 60% across the isolation barrier compared to fixed driving frequency method. The isolated converter’s output ripple is reduced by utilizing spread spectrum clocking in the driver. An isolated PMOS LDO in the secondary side is used to suppress switching noise and ripple by 21dB. Conducted and radiated EMI distribution on the IC is measured by a set of integrated ring oscillator based noise sensors with -68dBm noise sensitivity. The proposed isolated converter achieves highest level of integration with respect to earlier reported integrated isolated converters, while providing 50V on-chip junction isolation without the need for extra silicon post-processing steps.
ContributorsLiu, Chengxi (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kiaei, Sayfe (Committee member) / Song, Hongjiang (Committee member) / Kitchen, Jennifer (Committee member) / Arizona State University (Publisher)
Created2018
154420-Thumbnail Image.png
Description
This thesis aims to investigate the impacts of foreign banks’ management model on their degree of localization and operating efficiency. I decompose their management model into five major factors, including two formative factors and three reflective factors. The two formative factors are (1) strategic orientation and (2) target customers, and

This thesis aims to investigate the impacts of foreign banks’ management model on their degree of localization and operating efficiency. I decompose their management model into five major factors, including two formative factors and three reflective factors. The two formative factors are (1) strategic orientation and (2) target customers, and the three reflective factors are (1) top management team composition, (2) organizational structure, and (3) managerial authority and incentives. I propose that the formative factors influence foreign banks’ degree of localization, as demonstrated by the reflective factors, which subsequently influence foreign banks’ operating efficiency in China.

To test the above proposition, I conduct the empirical analysis in three steps. In the first step, I investigate foreign banks’ management model by surveying 13 major foreign banks locally incorporated in Mainland China. The results suggest that these 13 foreign banks can be categorized into three distinct groups based on their management model: intergrators, customer-followers, and parent-followers. The results also indicate that intergrators have the highest level of localization while parent-followers have the lowest level of localization.

In the second step, I conduct DEA (Data Envelope Analysis) and CAMEL (Capital Adequacy, Asset Quality, Management, Earnings, Liquidity Analysis) to assess the operating efficiency of these 13 foreign banks. The assessment is conducted in two ways: 1) the inter-group comparison between foreign banks and local Chinese banks; 2) the intra-group comparison between the three distinct groups of foreign banks identified in the first step. The results indicates that the principal factor driving the operating efficiency of both local Chinese banks and foreign banks is the comprehensive technical efficiency, which includes both the quality of management and the quality of technical elements. I also find the uptrend of technical efficiency of the integrators is more stable than that of the other two groups of foreign banks.

Finally, I integrate the results from step one and step two to assess the relevance between foreign banks’ localization level and operating efficiency. I find that foreign banks that score higher in localization tend to have a higher level of operating efficiency. Although this finding is not conclusive about the causal relationship between localization and operating efficiency, it nevertheless suggests that the management model of the higher performing integrators can serve as references for the other foreign banks attempting to enhance their localization and operating efficiency. I also discuss the future trends of development in the banking industry in China and what foreign banks can learn from local Chinese banks to improve their market positions.
ContributorsSun, Minjie (Author) / Shen, Wei (Thesis advisor) / Qian, Jun (Thesis advisor) / Pei, Ker-Wei (Committee member) / Arizona State University (Publisher)
Created2016
155974-Thumbnail Image.png
Description
High-efficiency DC-DC converters make up one of the important blocks of state-of-the-art power supplies. The trend toward high level of transistor integration has caused load current demands to grow significantly. Supplying high output current and minimizing output current ripple has been a driving force behind the evolution of Multi-phase topologies.

High-efficiency DC-DC converters make up one of the important blocks of state-of-the-art power supplies. The trend toward high level of transistor integration has caused load current demands to grow significantly. Supplying high output current and minimizing output current ripple has been a driving force behind the evolution of Multi-phase topologies. Ability to supply large output current with improved efficiency, reduction in the size of filter components, improved transient response make multi-phase topologies a preferred choice for low voltage-high current applications.

Current sensing capability inside a system is much sought after for applications which include Peak-current mode control, Current limiting, Overload protection. Current sensing is extremely important for current sharing in Multi-phase topologies. Existing approaches such as Series resistor, SenseFET, inductor DCR based current sensing are simple but their drawbacks such low efficiency, low accuracy, limited bandwidth demand a novel current sensing scheme.

This research presents a systematic design procedure of a 5V - 1.8V, 8A 4-Phase Buck regulator with a novel current sensing scheme based on replication of the inductor current. The proposed solution consists of detailed system modeling in PLECS which includes modification of the peak current mode model to accommodate the new current sensing element, derivation of power-stage and Plant transfer functions, Controller design. The proposed model has been verified through PLECS simulations and compared with a transistor-level implementation of the system. The time-domain parameters such as overshoot and settling-time simulated through transistor-level

implementation is in close agreement with the results obtained from the PLECS model.
ContributorsBurli, Venkatesh (Author) / Bakkaloglu, Bertan (Thesis advisor) / Garrity, Douglas (Committee member) / Kitchen, Jennifer (Committee member) / Arizona State University (Publisher)
Created2017
153596-Thumbnail Image.png
Description
The current study combines field study, survey study, and public financial reports, and conducts an in-depths comprehensive study of the cost of the global tire industry. By comparing the price and the total cost structure of standardized tire products, we investigate Chinese tire industry’s global competitiveness, especially in light of

The current study combines field study, survey study, and public financial reports, and conducts an in-depths comprehensive study of the cost of the global tire industry. By comparing the price and the total cost structure of standardized tire products, we investigate Chinese tire industry’s global competitiveness, especially in light of China’s fast increasing labor cost. By constructing a comprehensive cost index (CCI), this dissertation estimates the evolution and forecasts the trend of global tire industry’s cost structure. Based on our empirical analysis, we provide various recommendations for Chinese tire manufacturers, other manufacturing industries, and foreign trade policy makers.
ContributorsZhang, Ning (Author) / Zhu, Ning (Thesis advisor) / Shen, Wei (Thesis advisor) / Chen, Hong (Committee member) / Arizona State University (Publisher)
Created2015
128683-Thumbnail Image.png
Description

Unidirectional glass fiber reinforced polymer (GFRP) is tested at four initial strain rates (25, 50, 100 and 200 s-1) and six temperatures (−25, 0, 25, 50, 75 and 100 °C) on a servo-hydraulic high-rate testing system to investigate any possible effects on their mechanical properties and failure patterns. Meanwhile, for

Unidirectional glass fiber reinforced polymer (GFRP) is tested at four initial strain rates (25, 50, 100 and 200 s-1) and six temperatures (−25, 0, 25, 50, 75 and 100 °C) on a servo-hydraulic high-rate testing system to investigate any possible effects on their mechanical properties and failure patterns. Meanwhile, for the sake of illuminating strain rate and temperature effect mechanisms, glass yarn samples were complementally tested at four different strain rates (40, 80, 120 and 160 s-1) and varying temperatures (25, 50, 75 and 100 °C) utilizing an Instron drop-weight impact system. In addition, quasi-static properties of GFRP and glass yarn are supplemented as references. The stress–strain responses at varying strain rates and elevated temperatures are discussed. A Weibull statistics model is used to quantify the degree of variability in tensile strength and to obtain Weibull parameters for engineering applications.

ContributorsOu, Yunfu (Author) / Zhu, Deju (Author) / Zhang, Huaian (Author) / Huang, Liang (Author) / Yao, Yiming (Author) / Li, Gaosheng (Author) / Mobasher, Barzin (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2016-05-19