Matching Items (105)
171719-Thumbnail Image.png
Description
The energy consumed by buildings occupies a large part of energy consumption and carbon emissions. Meanwhile, enormous amounts of waste heat from buildings and the swiftly increasing demand for electric energy have become one of the essential contradictions that scientists pay attention to. As a result, how to make use

The energy consumed by buildings occupies a large part of energy consumption and carbon emissions. Meanwhile, enormous amounts of waste heat from buildings and the swiftly increasing demand for electric energy have become one of the essential contradictions that scientists pay attention to. As a result, how to make use of the waste heat to generate electric energy becomes an appreciable research topic. In the latest research, it is common to convert the thermal energy generated by the temperature difference into electrical energy using the Seebeck effect. In previous research, a prototype of a thermogalvanic cell with graphite as the electrodes and a combination of Iron (II) and Iron (III) perchlorate salts (Fe(ClO4)2, Fe(ClO4)3) as the electrolyte, and with a 3D-printed Schwarz-P structure, was designed and assembled for achieving the energy conversion. The research shows that the incorporation of a 3D-printed Schwarz-P structure improves the thermogalvanic cell’s performance and increases the temperature difference across the cell. Here we focus on the same type of thermogalvanic cell prototype and keep the same working temperature difference but use different electrolyte concentrations (0.05, 0.10, 0.15, 0.20, and 0.25 mol/L) to measure the electric output, including open-circuit voltage, short-circuit current, and maximum output power, and the internal resistance. The results indicate that the open-circuit voltage and maximum output power increase with the rise of electrolyte concentrations, and the short-circuit current decreases with the rise of electrolyte concentrations.
ContributorsHan, Xiaochuan (Author) / Phelan, Patric (Thesis advisor) / Huang, Huei-Ping (Committee member) / Bocanegra, Luis (Committee member) / Arizona State University (Publisher)
Created2022
Description
The Tesla valve, originating from Nikola Tesla's "valvular conduit" patent in 1920, offers a unique solution to fluid control challenges by enabling unidirectional flow while impeding reverse flow. With applications ranging from fluid pumps to high-power engines, Tesla's design functions as a fluidic diode, inducing pressure drops across the valve

The Tesla valve, originating from Nikola Tesla's "valvular conduit" patent in 1920, offers a unique solution to fluid control challenges by enabling unidirectional flow while impeding reverse flow. With applications ranging from fluid pumps to high-power engines, Tesla's design functions as a fluidic diode, inducing pressure drops across the valve to define its efficiency through diodicity. Through computational fluid dynamics (CFD) simulations using ANSYS Fluent, the impact of removing the bifurcated section on Tesla valve efficiency is explored. The T45-R, D-Valve, and GMF Valve designs are analyzed across a range of Reynolds numbers (Re). Results show that while the absence of bifurcation can lead to higher diodicity values due to increased flow divergence and vortex formation, efficiency varies depending on flow conditions. The T45-R valve exhibits linear diodicity increase with Reynolds number, plateauing at higher values due to reduced fluid inertia influence. Conversely, the D-Valve with bifurcation excels at lower Re values, while the non-bifurcated version proves more efficient at higher Re values. The GMF Valve with bifurcation demonstrates efficiency at lower Re values but decreases in effectiveness as Re rises, with the non-bifurcated version showing lower efficiency overall. Overall, this research provides insights into the fundamental physics and design considerations of Tesla valves, offering guidance for optimizing fluid control applications across diverse industries. The study underscores the importance of considering geometric variations and flow conditions when designing Tesla valves for specific applications, highlighting the intricate relationship between valve geometry, flow dynamics, and efficiency.
ContributorsWiley, Sean (Author) / Huang, Huei-Ping (Thesis director) / Kim, Jeonglae (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2024-05
191750-Thumbnail Image.png
Description
This thesis aims to determine how finite wing aerodynamic loads change in proximity to the ground. In this study, the primary design tool is an inviscid panel method code, VORLAX. The validation tool is a commercial volume grid CFD package, ANSYS FLUENT. I use VORLAX to simulate wings with different

This thesis aims to determine how finite wing aerodynamic loads change in proximity to the ground. In this study, the primary design tool is an inviscid panel method code, VORLAX. The validation tool is a commercial volume grid CFD package, ANSYS FLUENT. I use VORLAX to simulate wings with different incidences and aspect ratios to look at how ground effect impacts spanwise loading and incipient flow separation. Then the results were compared to widely published equations such as McCormick, Torenbeek, and Hoerner & Borst. Because I found that these “famous” equations function best only for specific conditions, I propose a new empirical equation to estimate ground effect lift as a function of aspect ratio and incidence. Using Stratford’s method to predict signs of flow separation in the inviscid solutions, I found that variations in the height above the ground were not significant enough to change the stall angle of low aspect ratio wings. I did find early signs of flow separation with increasing aspect ratio. I observe significant changes in spanwise loading when in ground effect; as I narrow the gap, the transverse loading builds higher near the center of the wing. These effects were more apparent in wings with smaller aspect ratio; higher aspect ratio wings experience a higher loading gradient near the tips in proximity to the ground. I found that high aspect ratio wings have a smaller stall angle compared to that of lower aspect ratio wings; these trends are consistent between the potential flow solution and the volume grid CFD viscous solution.
ContributorsValenzuela, Jose Vanir (Author) / Takahashi, Timothy (Thesis advisor) / Dahm, Werner (Committee member) / Huang, Huei-Ping (Committee member) / Arizona State University (Publisher)
Created2024
154025-Thumbnail Image.png
Description
This study uses the Weather Research and Forecasting (WRF) model to simulate and predict the changes in local climate attributed to the urbanization for five desert cities. The simulations are performed in the fashion of climate downscaling, constrained by the surface boundary conditions generated from high resolution land-use maps. For

This study uses the Weather Research and Forecasting (WRF) model to simulate and predict the changes in local climate attributed to the urbanization for five desert cities. The simulations are performed in the fashion of climate downscaling, constrained by the surface boundary conditions generated from high resolution land-use maps. For each city, the land-use maps of 1985 and 2010 from Landsat satellite observation, and a projected land-use map for 2030, are used to represent the past, present, and future. An additional set of simulations for Las Vegas, the largest of the five cities, uses the NLCD 1992 and 2006 land-use maps and an idealized historical land-use map with no urban coverage for 1900.

The study finds that urbanization in Las Vegas produces a classic urban heat island (UHI) at night but a minor cooling during the day. A further analysis of the surface energy balance shows that the decrease in surface Albedo and increase effective emissivity play an important role in shaping the local climate change over urban areas. The emerging urban structures slow down the diurnal wind circulation over the city due to an increased effective surface roughness. This leads to a secondary modification of temperature due to the interaction between the mechanical and thermodynamic effects of urbanization.

The simulations for the five desert cities for 1985 and 2010 further confirm a common pattern of the climatic effect of urbanization with significant nighttime warming and moderate daytime cooling. This effect is confined to the urban area and is not sensitive to the size of the city or the detail of land cover in the surrounding areas. The pattern of nighttime warming and daytime cooling remains robust in the simulations for the future climate of the five cities using the projected 2030 land-use maps. Inter-city differences among the five urban areas are discussed.
ContributorsKamal, Samy (Author) / Huang, Huei-Ping (Thesis advisor) / Anderson, James (Thesis advisor) / Herrmann, Marcus (Committee member) / Calhoun, Ronald (Committee member) / Myint, Soe (Committee member) / Arizona State University (Publisher)
Created2015
154266-Thumbnail Image.png
Description
The subject of this thesis is concerned with the amount of cooling air assigned to seal high pressure turbine rim cavities which is critical for performance as well as component life. Insufficient air leads to excessive hot annulus gas ingestion and its penetration deep into the cavity compromising disc life.

The subject of this thesis is concerned with the amount of cooling air assigned to seal high pressure turbine rim cavities which is critical for performance as well as component life. Insufficient air leads to excessive hot annulus gas ingestion and its penetration deep into the cavity compromising disc life. Excessive purge air, adversely affects performance. Experiments on a rotating turbine stage rig which included a rotor-stator forward disc cavity were performed at Arizona State University. The turbine rig has 22 vanes and 28 blades, while the rim cavity is composed of a single-tooth rim lab seal and a rim platform overlap seal. Time-averaged static pressures were measured in the gas path and the cavity, while mainstream gas ingestion into the cavity was determined by measuring the concentration distribution of tracer gas (carbon dioxide). Additionally, particle image velocimetry (PIV) was used to measure fluid velocity inside the rim cavity between the lab seal and the overlap. The data from the experiments were compared to an 360-degree unsteady RANS (URANS) CFD simulations. Although not able to match the time-averaged test data satisfactorily, the CFD simulations brought to light the unsteadiness present in the flow during the experiment which the slower response data did not fully capture. To interrogate the validity of URANS simulations in capturing complex rotating flow physics, the scope of this work also included to validating the CFD tool by comparing its predictions against experimental LDV data in a closed rotor-stator cavity. The enclosed cavity has a stationary shroud, a rotating hub, and mass flow does not enter or exit the system. A full 360 degree numerical simulation was performed comparing Fluent LES, with URANS turbulence models. Results from these investigations point to URANS state of art under-predicting closed cavity tangential velocity by 32% to 43%, and open rim cavity effectiveness by 50% compared to test data. The goal of this thesis is to assess the validity of URANS turbulence models in more complex rotating flows, compare accuracy with LES simulations, suggest CFD settings to better simulate turbine stage mainstream/disc cavity interaction with ingestion, and recommend experimentation techniques.
ContributorsKanjiyani, Shezan (Author) / Lee, Taewoo (Thesis advisor) / Mirzamoghadam, Alexander (Committee member) / Huang, Huei-Ping (Committee member) / Arizona State University (Publisher)
Created2016
157822-Thumbnail Image.png
Description
The world has been continuously urbanized and is currently accommodating more than half of the human population. Despite that cities cover only less than 3% of the Earth’s land surface area, they emerged as hotspots of anthropogenic activities. The drastic land use changes, complex three-dimensional urban terrain, and anthropogenic heat

The world has been continuously urbanized and is currently accommodating more than half of the human population. Despite that cities cover only less than 3% of the Earth’s land surface area, they emerged as hotspots of anthropogenic activities. The drastic land use changes, complex three-dimensional urban terrain, and anthropogenic heat emissions alter the transport of mass, heat, and momentum, especially within the urban canopy layer. As a result, cities are confronting numerous environmental challenges such as exacerbated heat stress, frequent air pollution episodes, degraded water quality, increased energy consumption and water use, etc. Green infrastructure, in particular, the use of trees, has been proved as an effective means to improve urban environmental quality in existing research. However, quantitative evaluations of the efficacy of urban trees in regulating air quality and thermal environment are impeded by the limited temporal and spatial scales in field measurements and the deficiency in numerical models.

This dissertation aims to advance the simulation of realistic functions of urban trees in both microscale and mesoscale numerical models, and to systematically evaluate the cooling capacity of urban trees under thermal extremes. A coupled large-eddy simulation–Lagrangian stochastic modeling framework is developed for the complex urban environment and is used to evaluate the impact of urban trees on traffic-emitted pollutants. Results show that the model is robust for capturing the dispersion of urban air pollutants and how strategically implemented urban trees can reduce vehicle-emitted pollution. To evaluate the impact of urban trees on the thermal environment, the radiative shading effect of trees are incorporated into the integrated Weather Research and Forecasting model. The mesoscale model is used to simulate shade trees over the contiguous United States, suggesting how the efficacy of urban trees depends on geographical and climatic conditions. The cooling capacity of urban trees and its response to thermal extremes are then quantified for major metropolitans in the United States based on remotely sensed data. It is found the nonlinear temperature dependence of the cooling capacity remarkably resembles the thermodynamic liquid-water–vapor equilibrium. The findings in this dissertation are informative to evaluating and implementing urban trees, and green infrastructure in large, as an important urban planning strategy to cope with emergent global environmental changes.
ContributorsWang, Chenghao (Author) / Wang, Zhihua (Thesis advisor) / Myint, Soe W. (Committee member) / Huang, Huei-Ping (Committee member) / Mascaro, Giuseppe (Committee member) / Arizona State University (Publisher)
Created2019
157707-Thumbnail Image.png
Description
This dissertation studies two outstanding microscale fluid mechanics problems: 1) mechanisms of gas production from the nanopores of shale; 2) enhanced mass flow rate in steady compressible gas flow through a micro-conduit.

The dissertation starts with a study of a volumetric expansion driven drainage flow of a viscous compressible fluid from

This dissertation studies two outstanding microscale fluid mechanics problems: 1) mechanisms of gas production from the nanopores of shale; 2) enhanced mass flow rate in steady compressible gas flow through a micro-conduit.

The dissertation starts with a study of a volumetric expansion driven drainage flow of a viscous compressible fluid from a small capillary and channel in the low Mach number limit. An analysis based on the linearized compressible Navier-Stokes equations with no-slip condition shows that fluid drainage is controlled by the slow decay of the acoustic wave inside the capillary and the no-slip flow exhibits a slip-like mass flow rate. Numerical simulations are also carried out for drainage from a small capillary to a reservoir or a contraction of finite size. By allowing the density wave to escape the capillary, two wave leakage mechanisms are identified, which are dependent on the capillary length to radius ratio, reservoir size and acoustic Reynolds number. Empirical functions are generated for an effective diffusive coefficient which allows simple calculations of the drainage rate using a diffusion model without the presence of the reservoir or contraction.

In the second part of the dissertation, steady viscous compressible flow through a micro-conduit is studied using compressible Navier-Stokes equations with no-slip condition. The mathematical theory of Klainerman and Majda for low Mach number flow is employed to derive asymptotic equations in the limit of small Mach number. The overall flow, a combination of the Hagen-Poiseuille flow and a diffusive velocity shows a slip-like mass flow rate even through the overall velocity satisfies the no-slip condition. The result indicates that the classical formulation includes self-diffusion effect and it embeds the Extended Navier-Stokes equation theory (ENSE) without the need of introducing additional constitutive hypothesis or assuming slip on the boundary. Contrary to most ENSE publications, the predicted mass flow rate is still significantly below the measured data based on an extensive comparison with thirty-five experiments.
ContributorsShen, Di (Author) / Chen, Kangping (Thesis advisor) / Herrmann, Marcus (Committee member) / Huang, Huei-Ping (Committee member) / Calhoun, Ronald (Committee member) / Lopez, Juan (Committee member) / Arizona State University (Publisher)
Created2019
157959-Thumbnail Image.png
Description
It is well known that radiative heat transfer rate can exceed that between two blackbodies by several orders of magnitude due to the coupling of evanescent waves. One promising application of near-field thermal radiation is thermophotovoltaic (TPV) devices, which convert thermal energy to electricity. Recently, different types of metamaterials with

It is well known that radiative heat transfer rate can exceed that between two blackbodies by several orders of magnitude due to the coupling of evanescent waves. One promising application of near-field thermal radiation is thermophotovoltaic (TPV) devices, which convert thermal energy to electricity. Recently, different types of metamaterials with excitations of surface plasmon polaritons (SPPs)/surface phonon polaritons (SPhPs), magnetic polaritons (MP), and hyperbolic modes (HM), have been studied to further improve near-field radiative heat flux and conversion efficiency. On the other hand, near-field experimental demonstration between planar surfaces has been limited due to the extreme challenge in the vacuum gap control as well as the parallelism.

The main objective of this work is to experimentally study the near-field radiative transfer and the excitation of resonance modes by designing nanostructured thin films separated by nanometer vacuum gaps. In particular, the near-field radiative heat transfer between two parallel plates of intrinsic silicon wafers coated with a thin film of aluminum nanostructure is investigated. In addition, theoretical studies about the effects of different physical mechanisms such as SPhP/SPP, MPs, and HM on near-field radiative transfer in various nanostructured metamaterials are conducted particularly for near-field TPV applications. Numerical simulations are performed by using multilayer transfer matrix method, rigorous coupled wave analysis, and finite difference time domain techniques incorporated with fluctuational electrodynamics. The understanding gained here will undoubtedly benefit the spectral control of near-field thermal radiation for energy-harvesting applications like thermophotovoltaic energy conversion and radiation-based thermal management.
ContributorsSabbaghi, Payam (Author) / Wang, Liping (Thesis advisor) / Phelan, Patrick (Committee member) / Huang, Huei-Ping (Committee member) / Wang, Robert (Committee member) / Yu, Hongbin (Committee member) / Arizona State University (Publisher)
Created2019
158064-Thumbnail Image.png
Description
Phononic crystals are artificially engineered materials that can forbid phonon propagation in a specific frequency range that is referred to as a “phononic band gap.” Phononic crystals that have band gaps in the GHz to THz range can potentially enable sophisticated control over thermal transport with “phononic devices”. Calculations of

Phononic crystals are artificially engineered materials that can forbid phonon propagation in a specific frequency range that is referred to as a “phononic band gap.” Phononic crystals that have band gaps in the GHz to THz range can potentially enable sophisticated control over thermal transport with “phononic devices”. Calculations of the phononic band diagram are the standard method of determining if a given phononic crystal structure has a band gap. However, calculating the phononic band diagram is a computationally expensive and time-consuming process that can require sophisticated modeling and coding. In addition to this computational burden, the inverse process of designing a phononic crystal with a specific band gap center frequency and width is a challenging problem that requires extensive trial-and-error work.

In this dissertation, I first present colloidal nanocrystal superlattices as a new class of three-dimensional phononic crystals with periodicity in the sub-20 nm size regime using the plane wave expansion method. These calculations show that colloidal nanocrystal superlattices possess phononic band gaps with center frequencies in the 102 GHz range and widths in the 101 GHz range. Varying the colloidal nanocrystal size and composition provides additional opportunities to fine-tune the phononic band gap. This suggests that colloidal nanocrystal superlattices are a promising platform for the creation of high frequency phononic crystals.

For the next topic, I explore opportunities to use supervised machine learning for expedited discovery of phononic band gap presence, center frequency and width for over 14,000 two-dimensional phononic crystal structures. The best trained model predicts band gap formation, center frequencies and band gap widths, with 94% accuracy and coefficients of determination (R2) values of 0.66 and 0.83, respectively.

Lastly, I expand the above machine learning approach to use machine learning to design a phononic crystal for a given set of phononic band gap properties. The best model could predict elastic modulus of host and inclusion, density of host and inclusion, and diameter-to-lattice constant ratio for target center and width frequencies with coefficients of determinations of 0.94, 0.98, 0.94, 0.71, and 0.94 respectively. The high values coefficients of determination represents great opportunity for phononic crystal design.
ContributorsSadat, Seid Mohamadali (Author) / Wang, Robert Y (Thesis advisor) / Huang, Huei-Ping (Committee member) / Ankit, Kumar (Committee member) / Wang, Liping (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2020
158296-Thumbnail Image.png
Description
Drainage flow of a viscous compressible gas from a semi-sealed narrow conduit is a pore-scale model for studying the fundamental flow physics of fluid recovery from a porous reservoir without using fluid injection. Thermal effect has been routinely neglected for these flows in the traditional petroleum engineering literature. Since the

Drainage flow of a viscous compressible gas from a semi-sealed narrow conduit is a pore-scale model for studying the fundamental flow physics of fluid recovery from a porous reservoir without using fluid injection. Thermal effect has been routinely neglected for these flows in the traditional petroleum engineering literature. Since the motion is entirely driven by volumetric expansion, temperature change always accompanies the density change. This thesis examines such thermal effects on the drainage flow.

Thermal drainage flow is first studied by simultaneously solving the linearized continuity, momentum and energy equations for adiabatic walls. It is shown that even in the absence of an imposed temperature drop, gas expansion induces a transient temperature decrease inside the channel, which slows down the drainage process compared to the isothermal model and Lighthill’s model. For a given density drop, gas drains out faster as the initial-to-final temperature ratio increases; and the transient density can undershoot the final equilibrium value. A parametric study is then carried out to explore the influence of various thermal boundary conditions on drainage flow. It is found that as the wall transitions from adiabatic to isothermal condition, the excess density changes from a plane wave solution to a non-plane wave solution and the drainage rate increases. It is shown that when the exit is also cooled and the wall is non-adiabatic, the total recovered fluid mass exceeds the amount based on the isothermal theory which is determined by the initial and final density difference alone. Finally, a full numerical simulation is conducted to mimic the channel-reservoir system using the finite volume method. The Ghost-Cell Navier-Stokes Characteristic Boundary Condition technique is applied at the far end of the truncated reservoir, which is an open boundary. The results confirm the conclusions of the linear theory.
ContributorsHuang, Wei (Author) / Chen, Kangping (Thesis advisor) / Huang, Huei-Ping (Committee member) / Herrmann, Marcus (Committee member) / Calhoun, Ronald (Committee member) / Baer, Steven (Committee member) / Arizona State University (Publisher)
Created2020