Matching Items (72)
157123-Thumbnail Image.png
Description
In the recent past, Iraq was considered relatively rich considering its water resources compared to its surroundings. Currently, the magnitude of water resource shortages in Iraq represents an important factor in the stability of the country and in protecting sustained economic development. The need for a practical, applicable, and sustainable

In the recent past, Iraq was considered relatively rich considering its water resources compared to its surroundings. Currently, the magnitude of water resource shortages in Iraq represents an important factor in the stability of the country and in protecting sustained economic development. The need for a practical, applicable, and sustainable river basin management for the Tigris and Euphrates Rivers in Iraq is essential. Applicable water resources allocation scenarios are important to minimize the potential future water crises in connection with water quality and quantity. The allocation of the available fresh water resources in addition to reclaimed water to different users in a sustainable manner is of the urgent necessities to maintain good water quantity and quality.

In this dissertation, predictive water allocation optimization models were developed which can be used to easily identify good alternatives for water management that can then be discussed, debated, adjusted, and simulated in greater detail. This study provides guidance for decision makers in Iraq for potential future conditions, where water supplies are reduced, and demonstrates how it is feasible to adopt an efficient water allocation strategy with flexibility in providing equitable water resource allocation considering alternative resource. Using reclaimed water will help in reducing the potential negative environmental impacts of treated or/and partially treated wastewater discharges while increasing the potential uses of reclaimed water for agriculture and other applications. Using reclaimed water for irrigation is logical and efficient to enhance the economy of farmers and the environment while providing a diversity of crops, especially since most of Iraq’s built or under construction wastewater treatment plants are located in or adjacent to agricultural lands. Adopting an optimization modelling approach can assist decision makers, ensuring their decisions will benefit the economy by incorporating global experiences to control water allocations in Iraq especially considering diminished water supplies.
ContributorsAhmed, Ahmed Abdulrazzaq (Author) / Mays, Larry W. (Thesis advisor) / Fox, Peter (Thesis advisor) / Mascaro, Giuseppe (Committee member) / Muenich, Rebecca (Committee member) / Arizona State University (Publisher)
Created2019
156966-Thumbnail Image.png
Description
C.C. Cragin Reservoir’s location in the Coconino National Forest, Arizona makes it prone to wild fire. This study focused on the potential impacts of such a wild fire on the reservoir’s annual thermal stratification cycle impacts and water quality. The annual thermal stratification cycle impacted the reservoir’s water

C.C. Cragin Reservoir’s location in the Coconino National Forest, Arizona makes it prone to wild fire. This study focused on the potential impacts of such a wild fire on the reservoir’s annual thermal stratification cycle impacts and water quality. The annual thermal stratification cycle impacted the reservoir’s water quality by increasing hypolimnion concentrations of magnesium, iron, turbidity, and specific ultraviolet absorbance (SUVA) values, as well as resulting in the hypolimnion having decreased dissolved oxygen concentrations during stratified months. The scarification process did not affect the dissolved organic carbon (DOC) concentrations in the reservoir or the total/dissolved nitrogen and phosphorous concentrations. Some general water quality trends that emerged were that phosphorous was the limiting nutrient, secchi disk depth and chlorophyll a concentration are inversely related, and no metals were found to be in concentrations that would violate an EPA drinking water maximum contaminant level (MCL). A carbon mass model was developed and parameterized using DOC measurements, and then using historic reservoir storage and weather data, the model simulated DOC concentrations in the reservoir following four hypothetical wild fire events. The model simulated varying initial reservoir storage volumes, initial flush volumes, and flush DOC concentrations, resulting in reservoir DOC concentrations varying from 17.41 mg/L to 8.82 mg/L.
ContributorsFlatebo, Theodore (Author) / Westerhoff, Paul K (Thesis advisor) / Fox, Peter (Committee member) / Perreault, Francois (Committee member) / Arizona State University (Publisher)
Created2018
156991-Thumbnail Image.png
Description
One of the two objectives of this dissertation is an investigation into the possible correlation between rainfall events and increased levels of E. coli and Mycobacterium using an existing data set. The literature states that levels of microbial concentrations do increase after rainfall events, but there are no studies to

One of the two objectives of this dissertation is an investigation into the possible correlation between rainfall events and increased levels of E. coli and Mycobacterium using an existing data set. The literature states that levels of microbial concentrations do increase after rainfall events, but there are no studies to indicate this correlation applies in any Arizona water systems. The data analyzed for the bacterial concentrations project suggested the possibility of a correlation along one river but it is not conclusive to state that any correlation exists between rainfall events and the microbial concentration for many other sites included in the analysis. This is most likely due to the highly engineered water delivery systems that are not directly impacted.

The secondary objective was to determine if there are environmental variables collected from an ongoing project which would be a good candidate for making predictions about any of the project data parameters. Of the 79 possible opportunities for the model to accurately predict the dependent variable, it showed strong statistical favorability as well as experimentally favorable results towards Dissolved Organic Carbon as the best dependent variable from the data set, resulting in an accuracy of 41%. This is relevant since Dissolved Organic Carbon is one of the most important water quality parameters of concern for drinking water treatment plants where disinfection by-products are a limiting factor. The need for further analysis and additional data collection is an obvious result from both studies. The use of hydrograph data instead of rainfall would be a logical new direction for the heavily engineered water delivery systems.
ContributorsBuell, Andrew (Author) / Fox, Peter (Thesis advisor) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2018
157075-Thumbnail Image.png
Description
The phrase water-energy nexus is commonly used to describe the inherent and critical interdependencies between the electric power system and the water supply systems (WSS). The key interdependencies between the two systems are the power plant’s requirement of water for the cooling cycle and the water system’s need of electricity

The phrase water-energy nexus is commonly used to describe the inherent and critical interdependencies between the electric power system and the water supply systems (WSS). The key interdependencies between the two systems are the power plant’s requirement of water for the cooling cycle and the water system’s need of electricity for pumping for water supply. While previous work has considered the dependency of WSS on the electrical power, this work incorporates into an optimization-simulation framework, consideration of the impact of short and long-term limited availability of water and/or electrical energy.

This research focuses on the water supply system (WSS) facet of the multi-faceted optimization and control mechanism developed for an integrated water – energy nexus system under U.S. National Science Foundation (NSF) project 029013-0010 CRISP Type 2 – Resilient cyber-enabled electric energy and water infrastructures modeling and control under extreme mega drought scenarios. A water supply system (WSS) conveys water from sources (such as lakes, rivers, dams etc.) to the treatment plants and then to users via the water distribution systems (WDS) and/or water supply canal systems (WSCS). Optimization-simulation methodologies are developed for the real-time operation of water supply systems (WSS) under critical conditions of limited electrical energy and/or water availability due to emergencies such as extreme drought conditions, electric grid failure, and other severe conditions including natural and manmade disasters. The coupling between WSS and the power system was done through alternatively exchanging data between the power system and WSS simulations via a program control overlay developed in python.

A new methodology for WDS infrastructural-operational resilience (IOR) computation was developed as a part of this research to assess the real-time performance of the WDS under emergency conditions. The methodology combines operational resilience and component level infrastructural robustness to provide a comprehensive performance assessment tool.

The optimization-simulation and resilience computation methodologies developed were tested for both hypothetical and real example WDS and WSCS, with results depicting improved resilience for operations of the WSS under normal and emergency conditions.
ContributorsKhatavkar, Puneet (Author) / Mays, Larry W. (Thesis advisor) / Vittal, Vijay (Committee member) / Mascaro, Giuseppe (Committee member) / Fox, Peter (Committee member) / Zhang, Junshan (Committee member) / Arizona State University (Publisher)
Created2019
131521-Thumbnail Image.png
Description
Turbidity is a known problem for UV water treatment systems as suspended particles can shield contaminants from the UV radiation. UV systems that utilize a reflective radiation chamber may be able to decrease the impact of turbidity on the efficacy of the system. The purpose of this study was to

Turbidity is a known problem for UV water treatment systems as suspended particles can shield contaminants from the UV radiation. UV systems that utilize a reflective radiation chamber may be able to decrease the impact of turbidity on the efficacy of the system. The purpose of this study was to determine how kaolin clay and gram flour turbidity affects inactivation of Escherichia coli (E. coli) when using a UV system with a reflective chamber. Both sources of turbidity were shown to reduce the inactivation of E. coli with increasing concentrations. Overall, it was shown that increasing kaolin clay turbidity had a consistent effect on reducing UV inactivation across UV doses. Log inactivation was reduced by 1.48 log for the low UV dose and it was reduced by at least 1.31 log for the low UV dose. Gram flour had a similar effect to the clay at the lower UV dose, reducing log inactivation by 1.58 log. At the high UV dose, there was no change in UV inactivation with an increase in turbidity. In conclusion, turbidity has a significant impact on the efficacy of UV disinfection. Therefore, removing turbidity from water is an essential process to enhance UV efficiency for the disinfection of microbial pathogens.
ContributorsMalladi, Rohith (Author) / Abbaszadegan, Morteza (Thesis director) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / School of Human Evolution & Social Change (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
134194-Thumbnail Image.png
Description
This report analyzes the potential for accumulation of boron in direct potable reuse. Direct potable reuse treats water through desalination processes such as reverse osmosis or nanofiltration which can achieve rejection rates of salts sometimes above 90%. However, boron achieves much lower rejection rates near 40%. Because of this low

This report analyzes the potential for accumulation of boron in direct potable reuse. Direct potable reuse treats water through desalination processes such as reverse osmosis or nanofiltration which can achieve rejection rates of salts sometimes above 90%. However, boron achieves much lower rejection rates near 40%. Because of this low rejection rate, there is potential for boron to accumulate in the system to levels that are not recommended for potable human consumption of water. To analyze this issue a code was created that runs a steady state system that tracks the internal concentration, permeate concentration, wastewater concentration and reject concentration at various rejection rates, as well as all the flows. A series of flow and mass balances were performed through five different control volumes that denoted different stages in the water use. First was mixing of clean water with permeate; second, consumptive uses; third, addition of contaminant; fourth, wastewater treatment; fifth, advanced water treatments. The system cycled through each of these a number of times until steady state was reached. Utilities or cities considering employing direct potable reuse could utilize this model by estimating their consumption levels and input of contamination, and then seeing what percent rejection or inflow of makeup water they would need to obtain to keep boron levels at a low enough concentration to be fit for consumption. This code also provides options for analyzing spikes and recovery in the system due to spills, and evaporative uses such as cooling towers and their impact on the system.
ContributorsDoidge, Sydney (Author) / Fox, Peter (Thesis director) / Perreault, Francois (Committee member) / Civil, Environmental and Sustainable Engineering Program (Contributor) / School of International Letters and Cultures (Contributor) / Barrett, The Honors College (Contributor)
Created2017-12
134310-Thumbnail Image.png
Description
The Prestige Worldwide Resort and development area will be constructed to the east of Scottsdale Rd and North of the 101 loop. The development area is composed of 442.58 acres of land within 9 parcels. Zoning for this development area consists of commercial, recreational, golf course, residential, and water/wastewater treatment.

The Prestige Worldwide Resort and development area will be constructed to the east of Scottsdale Rd and North of the 101 loop. The development area is composed of 442.58 acres of land within 9 parcels. Zoning for this development area consists of commercial, recreational, golf course, residential, and water/wastewater treatment. The main feature of the development area is a luxury resort to be located at the southwest corner of Legacy Blvd and Hayden Rd. The resort includes a large pond over which the entrance road traverses. The resort also includes an 18-hole golf course located just north of Legacy Blvd. The proposed residential area is to the east of Hayden Rd on the northern half of the site. Along the northeastern border of this residential area are APS, SRP, and Bureau of Reclamation easements. A recreational area in the form of a park is proposed to the east and west of the southern portion of N Hayden Rd on the site. The southeast corner or the site is reserved for water and wastewater treatment. The southwest corner of the site is for commercial use with an additional recreational/sporting area just to the north of this commercial area. The key feature of the resort is its luxurious eight-story hotel along with two other hotel buildings that accommodate tourists who are visiting Scottsdale. The main hotel includes 210 rooms to provide enough housing for these tourists and acquire more attraction to Scottsdale. The composition of the hotel consists of the first floor being the lobby and a recreational area. The other floors each contain 30 rooms, 3 elevators, and a staircase. Surrounding the hotel is a parking lot for the hotel guests and people attending events hosted at the hotel. Regarding the hotel specifications, two different alternative designs were produced to determine the ideal steel member type, concrete reinforcement, and the steel frame layout. The final hotel design was determined by which alternative had the lowest structural response from loading and cost effective.
ContributorsCastro, Cesar Aaron (Author) / Fox, Peter (Thesis director) / Templeton, Stephanie (Committee member) / Civil, Environmental and Sustainable Engineering Programs (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
136729-Thumbnail Image.png
Description
The rising need for water reuse in the Southwest United States has increased awareness of the quality of wastewater. This need is caused by an increased population having basic water needs; inefficient water use, such as overwatering lawns and leaking pipes; and recent drought conditions all over the southwestern US.

The rising need for water reuse in the Southwest United States has increased awareness of the quality of wastewater. This need is caused by an increased population having basic water needs; inefficient water use, such as overwatering lawns and leaking pipes; and recent drought conditions all over the southwestern US. Reclaimed water is a possible solution. It's used for a variety of non-potable, or non-drinkable, reasons. These uses include: cooling power plants, concrete mixing, artificial lakes, and irrigation for public parks and golf courts. Cooling power plants utilizes roughly 41% of the total water consumed by the United States, which makes it the highest user of water in the US. The attention is turned to optimizing mechanical processes and reducing the amount of water consumed. Wet-recirculating systems reuse cooling water in a second cycle rather than discharging it immediately. Cooling towers are commonly used to expose water to ambient air. As the water evaporates, more water is withdrawn while the rest continues to circulate. These systems have much lower water withdrawals than once-through systems, but have higher water consumption. The cooling towers in wet-recirculating plants and other warm machinery have two major limitations: evaporation of pumped water and scale formation in the components. Cooling towers circulate water, and only draw as it evaporates, which conserves water. The scale formation in the components is due to the hardness of the water. Scale occurs when hard water evaporates and forms solid calcium carbonate. This formation can lead to reduced flow or even clogging in pipes, fouling of components or pipes, and reduced cooling efficiency. Another concern from the public over the use of reclaimed water is the possibility of there being fecal contamination. This fear stems from the stigma associated with drinking water that essentially came from the toilet. An emerging technology, in order to address these three issues, is the use of an electromagnetic device. The wires have a current flowing through which induces a magnetic field perpendicular to the direction of the flow, while the electrical field is proportional to the flow velocity. In other words, the magnetic and electrical fields will create an effect that will concentrate cations at the center of the pipe and anions at the wall of the pipe or the other way depending on the direction of the flow. Reversing the field will then cause the cations and anions to move toward one another and increase the collision frequency and energy. The purpose of these experiments is to test the effects of the electromagnetic device on the aforementioned topics. There are three tests that were performed, a surface tension test, a hardness test, and a microbial test. The surface tension test focused on the angle of a water droplet until it burst. The angle would theoretically decrease as the bond between water molecules increased due to the device. The results of this test shows a lower angle for the treated water but a higher angle for the untreated one. This means the device had an effect on the surface tension of the water. Hard water is caused by calcium and magnesium ions in the water. These ions are dissolved in the water as it travels past soil and rocks. The purpose of this test is to measure the free calcium ion amount in the water. If the free calcium number lowers, then it can be assumed it collided with the carbonate and formed calcium carbonate. This calcium carbonate causes a reduction in hardness in the water. The result of the test showed no correlation between ion concentrations in the treated/untreated system. The e. coli test focused on testing the effects of an electromagnetic device on inhibiting fecal contamination in water/wastewater at a treatment facility. In order to detect fecal contamination, we test for bacteria known as fecal coliforms, more specifically e. coli. The test involved spiking the system with bacteria and testing its concentrations after time had passed.The e. coli results showed no trend in the inactivation of the bacteria. In conclusion, the device had varying results, but multiple steps can be taken in the future in order to continue research.
ContributorsHernandez, Andres Victor (Author) / Fox, Peter (Thesis director) / Abbaszadegan, Morteza (Committee member) / Civil, Environmental and Sustainable Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2014-12
133603-Thumbnail Image.png
Description
The purpose of this experiment was to determine how effective electromagnetic waves could be at reducing calcium hardness in a body of water as well as see how the makeup of the water (free calcium levels, total calcium levels, pH, alkalinity, and surface tension) were affected over the span of

The purpose of this experiment was to determine how effective electromagnetic waves could be at reducing calcium hardness in a body of water as well as see how the makeup of the water (free calcium levels, total calcium levels, pH, alkalinity, and surface tension) were affected over the span of testing. A vary of four different nominal calcium hardness levels, ranging from 80 mg/L \u2014 240 mg/L of calcium in terms of calcium hardness were tested over a span of thirty minutes with samples being taking once every ten minutes. Data collection indicates that there is a noticeable decrease in free calcium, total calcium, and pH over a span of thirty minutes using the electromagnetic device, however, no noticeable trend can be made for the alkalinity and surface tension. Errors can be stated to be caused by lack of protocol for calcium hardness creation as well as needed updates for procedures such as alkalinity and surface tension testing. It can be deduced that the process is favorable, but it cannot be concluded as to whether to not this device can become a sustainable alternative to salt-based water softeners.
ContributorsNnorom, Njideka Cynthia (Author) / Fox, Peter (Thesis director) / Atkinson, Ariel (Committee member) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
134712-Thumbnail Image.png
Description
Over the last century, society has begun to acknowledge and observe how human actions are negatively impacting the environment. Sustainable living is becoming more adopted into daily lives, including a focus on waste management and recycling. Previous informal studies have proposed that coffee grounds can be recycled and added to

Over the last century, society has begun to acknowledge and observe how human actions are negatively impacting the environment. Sustainable living is becoming more adopted into daily lives, including a focus on waste management and recycling. Previous informal studies have proposed that coffee grounds can be recycled and added to the soil to increase plant productivity. The objective of this experiment was to test how different concentrations of roasted coffee grounds would affect the overall plant productivity when introduced in the soil of various plant types and environmental atmospheres. Three treatments were selected (100% potting mix, 50% potting mix/50% coffee grounds, and 25% potting mix/75% coffee grounds) and applied to 3 acid-tolerating plants (radish, basil, and parsley). Each of these treatments were grown in 2 different environments, where one was planted in a Tempe, AZ backyard while the other group was planted in a lab environment, locating at Arizona State University's Tempe Campus. Each plant with its respective treatments (plant type, coffee ground treatment, and environment) had 10 identical plants for statistical accuracy, resulting in a total of 180 plants grown, observed, and analyzed for this 3-month long experiment. The plant development, plant height, length of roots, quantity of leaves, and environmental observations were recorded and used to define plant productivity in this investigation. The experiment demonstrated low survival rates in all groups including the control group, suggesting a flaw in the experimental design. Nonetheless, the experiment showed that among the surviving plants, the 75% treatment had the largest negative impact on plant productivity. The measured root lengths and leaf quantity had various results across each plant group, leaving the hypothesis unverified. Overall, the experiment was effective in demonstrating negative impacts of great concentrations of coffee grounds when introduced to various plants, but further investigation with an adjusted experimental design will need to be completed to reach a reliable conclusion.
ContributorsVan Winkle, Delaney Dare (Author) / Bang, Christofer (Thesis director) / Fox, Peter (Committee member) / Earl, Stevan (Committee member) / School of Sustainability (Contributor) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12