Matching Items (432)
150400-Thumbnail Image.png
Description
Semiconductor nanowires are featured by their unique one-dimensional structure which makes them promising for small scale electronic and photonic device applications. Among them, III-V material nanowires are particularly outstanding due to their good electronic properties. In bulk, these materials reveal electron mobility much higher than conventional silicon based devices, for

Semiconductor nanowires are featured by their unique one-dimensional structure which makes them promising for small scale electronic and photonic device applications. Among them, III-V material nanowires are particularly outstanding due to their good electronic properties. In bulk, these materials reveal electron mobility much higher than conventional silicon based devices, for example at room temperature, InAs field effect transistor (FET) has electron mobility of 40,000 cm2/Vs more than 10 times of Si FET. This makes such materials promising for high speed nanowire FETs. With small bandgap, such as 0.354 eV for InAs and 1.52 eV for GaAs, it does not need high voltage to turn on such devices which leads to low power consumption devices. Another feature of direct bandgap allows their applications of optoelectronic devices such as avalanche photodiodes. However, there are challenges to face up. Due to their large surface to volume ratio, nanowire devices typically are strongly affected by the surface states. Although nanowires can be grown into single crystal structure, people observe crystal defects along the wires which can significantly affect the performance of devices. In this work, FETs made of two types of III-V nanowire, GaAs and InAs, are demonstrated. These nanowires are grown by catalyst-free MOCVD growth method. Vertically nanowires are transferred onto patterned substrates for coordinate calibration. Then electrodes are defined by e-beam lithography followed by deposition of contact metals. Prior to metal deposition, however, the substrates are dipped in ammonium hydroxide solution to remove native oxide layer formed on nanowire surface. Current vs. source-drain voltage with different gate bias are measured at room temperature. GaAs nanowire FETs show photo response while InAs nanowire FETs do not show that. Surface passivation is performed on GaAs FETs by using ammonium surfide solution. The best results on current increase is observed with around 20-30 minutes chemical treatment time. Gate response measurements are performed at room temperature, from which field effect mobility as high as 1490 cm2/Vs is extracted for InAs FETs. One major contributor for this is stacking faults defect existing along nanowires. For InAs FETs, thermal excitations observed from temperature dependent results which leads us to investigate potential barriers.
ContributorsLiang, Hanshuang (Author) / Yu, Hongbin (Thesis advisor) / Ferry, David (Committee member) / Tracy, Clarence (Committee member) / Arizona State University (Publisher)
Created2011
152001-Thumbnail Image.png
Description
Despite significant advances in digital pathology and automation sciences, current diagnostic practice for cancer detection primarily relies on a qualitative manual inspection of tissue architecture and cell and nuclear morphology in stained biopsies using low-magnification, two-dimensional (2D) brightfield microscopy. The efficacy of this process is limited by inter-operator variations in

Despite significant advances in digital pathology and automation sciences, current diagnostic practice for cancer detection primarily relies on a qualitative manual inspection of tissue architecture and cell and nuclear morphology in stained biopsies using low-magnification, two-dimensional (2D) brightfield microscopy. The efficacy of this process is limited by inter-operator variations in sample preparation and imaging, and by inter-observer variability in assessment. Over the past few decades, the predictive value quantitative morphology measurements derived from computerized analysis of micrographs has been compromised by the inability of 2D microscopy to capture information in the third dimension, and by the anisotropic spatial resolution inherent to conventional microscopy techniques that generate volumetric images by stacking 2D optical sections to approximate 3D. To gain insight into the analytical 3D nature of cells, this dissertation explores the application of a new technology for single-cell optical computed tomography (optical cell CT) that is a promising 3D tomographic imaging technique which uses visible light absorption to image stained cells individually with sub-micron, isotropic spatial resolution. This dissertation provides a scalable analytical framework to perform fully-automated 3D morphological analysis from transmission-mode optical cell CT images of hematoxylin-stained cells. The developed framework performs rapid and accurate quantification of 3D cell and nuclear morphology, facilitates assessment of morphological heterogeneity, and generates shape- and texture-based biosignatures predictive of the cell state. Custom 3D image segmentation methods were developed to precisely delineate volumes of interest (VOIs) from reconstructed cell images. Comparison with user-defined ground truth assessments yielded an average agreement (DICE coefficient) of 94% for the cell and its nucleus. Seventy nine biologically relevant morphological descriptors (features) were computed from the segmented VOIs, and statistical classification methods were implemented to determine the subset of features that best predicted cell health. The efficacy of our proposed framework was demonstrated on an in vitro model of multistep carcinogenesis in human Barrett's esophagus (BE) and classifier performance using our 3D morphometric analysis was compared against computerized analysis of 2D image slices that reflected conventional cytological observation. Our results enable sensitive and specific nuclear grade classification for early cancer diagnosis and underline the value of the approach as an objective adjunctive tool to better understand morphological changes associated with malignant transformation.
ContributorsNandakumar, Vivek (Author) / Meldrum, Deirdre R (Thesis advisor) / Nelson, Alan C. (Committee member) / Karam, Lina J (Committee member) / Ye, Jieping (Committee member) / Johnson, Roger H (Committee member) / Bussey, Kimberly J (Committee member) / Arizona State University (Publisher)
Created2013
Description
In the frenzy of next generation genetic sequencing and proteomics, single-cell level analysis has begun to find its place in the crux of personalized medicine and cancer research. Single live cell 3D imaging technology is one of the most useful ways of providing spatial and morphological details inside living single

In the frenzy of next generation genetic sequencing and proteomics, single-cell level analysis has begun to find its place in the crux of personalized medicine and cancer research. Single live cell 3D imaging technology is one of the most useful ways of providing spatial and morphological details inside living single cells. It provides a window to uncover the mysteries of protein structure and folding, as well as genetic expression over time, which will tremendously improve the state of the fields of biophysics and biomedical research. This thesis project specifically demonstrates a method for live single cell rotation required to image them in the single live cell CT imaging platform. The method of rotation proposed in this thesis uses dynamic optical traps generated by a phase-only spatial light modulator (SLM) to exert torque on a single mammalian cell. Laser patterns carrying the holographic information of the traps are delivered from the SLM through a transformation telescope into the objective lens and onto its focal plane to produce the desired optical trap "image". The phase information in the laser patterns being delivered are continuously altered by the SLM such that the structure of the wavefront produces two foci at opposite edges of the cell of interest that each moves along the circumference of the cell in opposite axial directions. Momentum generated by the motion of the foci exerts a torque on the cell, causing it to rotate. The viability of this method was demonstrated experimentally. Software was written using LabVIEW to control the display panel of the SLM.
ContributorsChan, Samantha W (Author) / Meldrum, Deridre R (Thesis advisor) / Kleim, Jeffrey A (Committee member) / Johnson, Roger H (Committee member) / Kelbauskas, Laimonas (Committee member) / Arizona State University (Publisher)
Created2013
Description
Volumetric cell imaging using 3D optical Computed Tomography (cell CT) is advantageous for identification and characterization of cancer cells. Many diseases arise from genomic changes, some of which are manifest at the cellular level in cytostructural and protein expression (functional) features which can be resolved, captured and quantified in 3D

Volumetric cell imaging using 3D optical Computed Tomography (cell CT) is advantageous for identification and characterization of cancer cells. Many diseases arise from genomic changes, some of which are manifest at the cellular level in cytostructural and protein expression (functional) features which can be resolved, captured and quantified in 3D far more sensitively and specifically than in traditional 2D microscopy. Live single cells were rotated about an axis perpendicular to the optical axis to facilitate data acquisition for functional live cell CT imaging. The goal of this thesis research was to optimize and characterize the microvortex rotation chip. Initial efforts concentrated on optimizing the microfabrication process in terms of time (6-8 hours v/s 12-16 hours), yield (100% v/s 40-60%) and ease of repeatability. This was done using a tilted exposure lithography technique, as opposed to the backside diffuser photolithography (BDPL) method used previously (Myers 2012) (Chang and Yoon 2004). The fabrication parameters for the earlier BDPL technique were also optimized so as to improve its reliability. A new, PDMS to PDMS demolding process (soft lithography) was implemented, greatly improving flexibility in terms of demolding and improving the yield to 100%, up from 20-40%. A new pump and flow sensor assembly was specified, tested, procured and set up, allowing for both pressure-control and flow-control (feedback-control) modes; all the while retaining the best features of a previous, purpose-built pump assembly. Pilot experiments were performed to obtain the flow rate regime required for cell rotation. These experiments also allowed for the determination of optimal trapezoidal neck widths (opening to the main flow channel) to be used for cell rotation characterization. The optimal optical trap forces were experimentally estimated in order to minimize the required optical power incident on the cell. Finally, the relationships between (main channel) flow rates and cell rotation rates were quantified for different trapezoidal chamber dimensions, and at predetermined constant values of laser trapping strengths, allowing for parametric characterization of the system.
ContributorsShetty, Rishabh M (Author) / Meldrum, Deirdre R (Thesis advisor) / Johnson, Roger H (Committee member) / Tillery, Stephen H (Committee member) / Arizona State University (Publisher)
Created2013
150927-Thumbnail Image.png
Description
Due to heterogeneity at the cellular level, single cell analysis (SCA) has become a necessity to study cellomics for the early detection of diseases like cancer. Development of single cell manipulation systems is very critical for performing SCA. In this thesis, electrorotation (ROT) chips to trap and rotate single cells

Due to heterogeneity at the cellular level, single cell analysis (SCA) has become a necessity to study cellomics for the early detection of diseases like cancer. Development of single cell manipulation systems is very critical for performing SCA. In this thesis, electrorotation (ROT) chips to trap and rotate single cells using electrokinetic forces have been developed. The ROT chip mainly consists of a set of closely spaced metal electrodes (60µm interspacing between opposite electrodes) that forms a closed electric field cage (electrocage) when driven with high frequency AC voltages. Cells were flowed through a microchannel to the electrocage where they could be precisely trapped, levitated and rotated in 3-D along the axis of interest. The dielectrophoresis based ROT chip design and relevant electrokinetic effects have been simulated using COMSOL 3.4 to optimize the design parameters. Also, various semiconductor technology fabrication process steps have been developed and optimized for better yield and repeatability in the manufacture of the ROT chip. The ROT chip thus fabricated was used to characterize rotation of single cells with respect to the control parameters namely excitation voltage, frequency and cell line. The longevity of cell rotation under electric fields has been probed. Also, the Joule heating inside the ROT chip due to applied voltage has been characterized to know the thermal stress on the cells. The major advantages of the ROT chip developed are precise electrorotation of cells, simple design and straight forward fabrication process.
ContributorsSoundappa Elango, Iniyan (Author) / Meldrum, Deirdre R (Thesis advisor) / Christen, Jennifer Blain (Committee member) / Johnson, Roger H (Committee member) / Arizona State University (Publisher)
Created2012
150443-Thumbnail Image.png
Description
ABSTRACT An Ensemble Monte Carlo (EMC) computer code has been developed to simulate, semi-classically, spin-dependent electron transport in quasi two-dimensional (2D) III-V semiconductors. The code accounts for both three-dimensional (3D) and quasi-2D transport, utilizing either 3D or 2D scattering mechanisms, as appropriate. Phonon, alloy, interface roughness, and impurity scattering mechanisms

ABSTRACT An Ensemble Monte Carlo (EMC) computer code has been developed to simulate, semi-classically, spin-dependent electron transport in quasi two-dimensional (2D) III-V semiconductors. The code accounts for both three-dimensional (3D) and quasi-2D transport, utilizing either 3D or 2D scattering mechanisms, as appropriate. Phonon, alloy, interface roughness, and impurity scattering mechanisms are included, accounting for the Pauli Exclusion Principle via a rejection algorithm. The 2D carrier states are calculated via a self-consistent 1D Schrödinger-3D-Poisson solution in which the charge distribution of the 2D carriers in the quantization direction is taken as the spatial distribution of the squared envelope functions within the Hartree approximation. The wavefunctions, subband energies, and 2D scattering rates are updated periodically by solving a series of 1D Schrödinger wave equations (SWE) over the real-space domain of the device at fixed time intervals. The electrostatic potential is updated by periodically solving the 3D Poisson equation. Spin-polarized transport is modeled via a spin density-matrix formalism that accounts for D'yakanov-Perel (DP) scattering. Also, the code allows for the easy inclusion of additional scattering mechanisms and structural modifications to devices. As an application of the simulator, the current voltage characteristics of an InGaAs/InAlAs HEMT are simulated, corresponding to nanoscale III-V HEMTs currently being fabricated by Intel Corporation. The comparative effects of various scattering parameters, material properties and structural attributes are investigated and compared with experiments where reasonable agreement is obtained. The spatial evolution of spin-polarized carriers in prototypical Spin Field Effect Transistor (SpinFET) devices is then simulated. Studies of the spin coherence times in quasi-2D structures is first investigated and compared to experimental results. It is found that the simulated spin coherence times for GaAs structures are in reasonable agreement with experiment. The SpinFET structure studied is a scaled-down version of the InGaAs/InAlAs HEMT discussed in this work, in which spin-polarized carriers are injected at the source, and the coherence length is studied as a function of gate voltage via the Rashba effect.
ContributorsTierney, Brian David (Author) / Goodnick, Stephen (Thesis advisor) / Ferry, David (Committee member) / Akis, Richard (Committee member) / Saraniti, Marco (Committee member) / Vasileska, Dragica (Committee member) / Arizona State University (Publisher)
Created2011
137546-Thumbnail Image.png
Description
In vitro measurements of cellular respiration have proven to be key biomarkers for the early onset of tumor formation in certain pathological mechanisms.1 The examination of isolated single cells has shown promise in predicting the onset of cancerous growth much earlier than current methods allow.2 Specifically, measurements of the oxygen

In vitro measurements of cellular respiration have proven to be key biomarkers for the early onset of tumor formation in certain pathological mechanisms.1 The examination of isolated single cells has shown promise in predicting the onset of cancerous growth much earlier than current methods allow.2 Specifically, measurements of the oxygen consumption rates of precancerous cells have elucidated outliers which predict the early onset of esophageal cancer.2 Single cell profiling can fit in to current pathology studies and can serve as a step along the way, much like PCR or gel assays, in detecting biomarkers earlier than current clinical methods.3 Measurement of these single cell metabolic rates is currently limited to 25 cells per experiment. It is the aim of this project to increase throughput from 25 cells to 225 cells per experiment via the implementation of new hardware and software which fit with current methods to allow the same experimental structure. Successful implementation of such methods will allow for more rapid and efficient data collection, facilitating quantitative results and nine times the yield from the same experimental manpower and funding. This document focuses on the implementation ultra high density (UHD) hardware consisting of a pneumatic molar design, angular adjustment features and a mechanical Z-stage. These components have produced the most encouraging results thus far and are the key changes in transitioning to higher throughput experiments.
ContributorsUeberroth, Benjamin Edward (Author) / Kelbauskas, Laimonas (Thesis director) / Ashili, Shashanka (Committee member) / Myers, Jakrey (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor) / School of Life Sciences (Contributor)
Created2013-05
137396-Thumbnail Image.png
Description
Esophageal adenocarcinoma (EAC) is one of the most lethal and fastest growing cancers in the United States. Its onset is commonly triggered by metaplastic transformation of normal squamous esophageal epithelial cells to Barrett's esophagus (BE) cells in response to acid reflux. BE patients are believed to progress through non-dysplastic metaplasia

Esophageal adenocarcinoma (EAC) is one of the most lethal and fastest growing cancers in the United States. Its onset is commonly triggered by metaplastic transformation of normal squamous esophageal epithelial cells to Barrett's esophagus (BE) cells in response to acid reflux. BE patients are believed to progress through non-dysplastic metaplasia and increasing grades of dysplasia prior to EAC. Conventional cancer diagnostic tools rely on bulk-cell analyses that are incapable of identifying intratumoral heterogeneity or rare driver cells that play important roles in cancer progression. An improved single-cell method of cancer diagnosis would overcome this challenge by detecting cancer initiating cells before they progress into untreatable stages. In this study, using EAC as a model, we attempted to identify a more effective method of cancer diagnosis. We quantified the single- and bulk-cell mRNA expression of genes that have been proposed to be instrumental in the progression of EAC through BE. Quantitative Reverse Transcription Polymerase Chain Reaction (qRT-PCR) analysis was performed on human primary cells to measure the mRNA expression levels of BE- and EAC-associated genes. Our results showed high levels of heterogeneity of CDX2 and TFF3 at the single-cell resolution in human BE and EAC samples. Additionally, while expression of VEGF is generally low at the bulk-cell level, our results showed that a few, rare cells had significantly higher VEGF expression levels than the majority of cells in the EAC sample. In conclusion, we have affirmed that EAC cancer cells, as well as BE cells, show high levels of heterogeneity. Based on the VEGF gene expression pattern, single-cell analysis could potentially be more effective for identifying rare, but essential cells for cancer progression, which could then be targeted for treatment. Future studies will focus on analyzing human samples from thousands of normal and cancer subjects to validate the use of single-cell profiling in cancer.
ContributorsHaeuser, Kelsey Lynn (Author) / Tran, Thai (Thesis director) / Kelbauskas, Laimonas (Committee member) / Gao, Weimin (Committee member) / Barrett, The Honors College (Contributor) / School of Life Sciences (Contributor)
Created2013-12
141462-Thumbnail Image.png
Description

Despite the fact that seizures are commonly associated with autism spectrum disorder (ASD), the effectiveness of treatments for seizures has not been well studied in individuals with ASD. This manuscript reviews both traditional and novel treatments for seizures associated with ASD. Studies were selected by systematically searching major electronic databases

Despite the fact that seizures are commonly associated with autism spectrum disorder (ASD), the effectiveness of treatments for seizures has not been well studied in individuals with ASD. This manuscript reviews both traditional and novel treatments for seizures associated with ASD. Studies were selected by systematically searching major electronic databases and by a panel of experts that treat ASD individuals. Only a few anti-epileptic drugs (AEDs) have undergone carefully controlled trials in ASD, but these trials examined outcomes other than seizures. Several lines of evidence point to valproate, lamotrigine, and levetiracetam as the most effective and tolerable AEDs for individuals with ASD. Limited evidence supports the use of traditional non-AED treatments, such as the ketogenic and modified Atkins diet, multiple subpial transections, immunomodulation, and neurofeedback treatments. Although specific treatments may be more appropriate for specific genetic and metabolic syndromes associated with ASD and seizures, there are few studies which have documented the effectiveness of treatments for seizures for specific syndromes. Limited evidence supports l-carnitine, multivitamins, and N-acetyl-l-cysteine in mitochondrial disease and dysfunction, folinic acid in cerebral folate abnormalities and early treatment with vigabatrin in tuberous sclerosis complex. Finally, there is limited evidence for a number of novel treatments, particularly magnesium with pyridoxine, omega-3 fatty acids, the gluten-free casein-free diet, and low-frequency repetitive transcranial magnetic simulation. Zinc and l-carnosine are potential novel treatments supported by basic research but not clinical studies. This review demonstrates the wide variety of treatments used to treat seizures in individuals with ASD as well as the striking lack of clinical trials performed to support the use of these treatments. Additional studies concerning these treatments for controlling seizures in individuals with ASD are warranted.

ContributorsFrye, Richard E. (Author) / Rossignol, Daniel (Author) / Casanova, Manuel F. (Author) / Brown, Gregory L. (Author) / Martin, Victoria (Author) / Edelson, Stephen (Author) / Coben, Robert (Author) / Lewine, Jeffrey (Author) / Slattery, John C. (Author) / Lau, Chrystal (Author) / Hardy, Paul (Author) / Fatemi, S. Hossein (Author) / Folsom, Timothy D. (Author) / MacFabe, Derrick (Author) / Adams, James (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2013-09-13
141466-Thumbnail Image.png
Description

There is a growing body of scientific evidence that the health of the microbiome (the trillions of microbes that inhabit the human host) plays an important role in maintaining the health of the host and that disruptions in the microbiome may play a role in certain disease processes. An increasing

There is a growing body of scientific evidence that the health of the microbiome (the trillions of microbes that inhabit the human host) plays an important role in maintaining the health of the host and that disruptions in the microbiome may play a role in certain disease processes. An increasing number of research studies have provided evidence that the composition of the gut (enteric) microbiome (GM) in at least a subset of individuals with autism spectrum disorder (ASD) deviates from what is usually observed in typically developing individuals. There are several lines of research that suggest that specific changes in the GM could be causative or highly associated with driving core and associated ASD symptoms, pathology, and comorbidities which include gastrointestinal symptoms, although it is also a possibility that these changes, in whole or in part, could be a consequence of underlying pathophysiological features associated with ASD. However, if the GM truly plays a causative role in ASD, then the manipulation of the GM could potentially be leveraged as a therapeutic approach to improve ASD symptoms and/or comorbidities, including gastrointestinal symptoms.

One approach to investigating this possibility in greater detail includes a highly controlled clinical trial in which the GM is systematically manipulated to determine its significance in individuals with ASD. To outline the important issues that would be required to design such a study, a group of clinicians, research scientists, and parents of children with ASD participated in an interdisciplinary daylong workshop as an extension of the 1st International Symposium on the Microbiome in Health and Disease with a Special Focus on Autism (www.microbiome-autism.com). The group considered several aspects of designing clinical studies, including clinical trial design, treatments that could potentially be used in a clinical trial, appropriate ASD participants for the clinical trial, behavioral and cognitive assessments, important biomarkers, safety concerns, and ethical considerations. Overall, the group not only felt that this was a promising area of research for the ASD population and a promising avenue for potential treatment but also felt that further basic and translational research was needed to clarify the clinical utility of such treatments and to elucidate possible mechanisms responsible for a clinical response, so that new treatments and approaches may be discovered and/or fostered in the future.

ContributorsFrye, Richard E. (Author) / Slattery, John (Author) / MacFabe, Derrick F. (Author) / Allen-Vercoe, Emma (Author) / Parker, William (Author) / Rodakis, John (Author) / Adams, James (Author) / Krajmalnik-Brown, Rosa (Author) / Bolte, Ellen (Author) / Kahler, Stephen (Author) / Jennings, Jana (Author) / James, Jill (Author) / Cerniglia, Carl E. (Author) / Midtvedt, Tore (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-05-07