Matching Items (223)
136195-Thumbnail Image.png
Description
The intervertebral disc goes through degenerative changes with age, which leads to disc thinning, bulging, or herniation. Spinal fusion treatments are ineffective as they cause quicker degeneration of adjacent discs and fail in nearly 20% of cases, so researchers have turned to tissue-engineering biocompatible intervertebral discs for transplantation. However novel

The intervertebral disc goes through degenerative changes with age, which leads to disc thinning, bulging, or herniation. Spinal fusion treatments are ineffective as they cause quicker degeneration of adjacent discs and fail in nearly 20% of cases, so researchers have turned to tissue-engineering biocompatible intervertebral discs for transplantation. However novel and effective as this may seem, these transplanted discs still show evidence of degeneration after just 5 years. I hypothesize that these discs are degenerating due to a blockage of the cartilaginous endplates post-transplantation that is hindering nutrient transport through the intervertebral disc. In order to test this hypothesis, I developed a mathematical model of nutrient transport through the intervertebral disc in one diurnal daily loading cycle. This model was used to simulate open endplates and blocked endplates and then compare differences in nutrient concentration and nutrient transport to the center of the disc. Results from the math model simulations were then compared to in vitro experimental data collected in lab to verify the findings on a physiological level. Results showed significant differences, both in vitro and in the model, between nutrient transport in open endplates vs blocked endplates, lending support to the original hypothesis. This study only presents preliminary results, but could hold the key to preventing future disc degeneration post-transplantation.
ContributorsMunter, Bryce Taylor (Author) / Santello, Marco (Thesis director) / Caplan, Michael (Committee member) / Giers, Morgan (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
135691-Thumbnail Image.png
Description
Previous research has found improvements in motor and cognitive measures following Assisted Cycle Therapy (AC) in adolescence with Down syndrome (DS). Our study investigated whether we would find improvements in older adults with DS on measures of leisure physical activity (GLTEQ) and sleep, which are early indicators of Alzheimer's disease

Previous research has found improvements in motor and cognitive measures following Assisted Cycle Therapy (AC) in adolescence with Down syndrome (DS). Our study investigated whether we would find improvements in older adults with DS on measures of leisure physical activity (GLTEQ) and sleep, which are early indicators of Alzheimer's disease (AD) in persons with Down syndrome. This study consisted of eight participants with Down syndrome between 31 and 51 years old that cycled for 30 minutes 3 x/week for eight weeks either at their voluntary cycling rate (VC) or approximately 35% faster with the help of a mechanical motor (AC). We predicted that, based on pilot data (Gomez, 2015), GLTEQ would either maintain or improve after AC, but would decrease after VC and would stay the same after NC. We predicted that the sleep score may improve after both VC or AC or it may improve more after VC than AC based on pilot data related to leisure activity. Our results were consistent with our prediction that GLTEQ will either maintain or improve after AC but will decrease after VC. Our results were not consistent with our prediction that sleep may improve after both VC or AC or it may improve more after VC than AC, possibly because we did not pre-screen for sleep disorders. Future research should focus on recruiting more participants and using both objective and subjective measures of sleep and physical activity to improve the efficacy of the study.
ContributorsParker, Lucas Maury (Author) / Ringenbach, Shannon (Thesis director) / Buman, Matthew (Committee member) / Holzapfel, Simon (Committee member) / School of Social and Behavioral Sciences (Contributor) / School of Nutrition and Health Promotion (Contributor) / College of Public Service and Community Solutions (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
135593-Thumbnail Image.png
Description
The effect of conflicting sensorimotor memories on optimal force strategies was explored. Subjects operated a virtual object controlled by a physical handle to complete a simple straight-line task. Perturbations applied to the handle induced a period of increased error in subject accuracy. After two blocks of 33 trials, perturbations switched

The effect of conflicting sensorimotor memories on optimal force strategies was explored. Subjects operated a virtual object controlled by a physical handle to complete a simple straight-line task. Perturbations applied to the handle induced a period of increased error in subject accuracy. After two blocks of 33 trials, perturbations switched direction, inducing increased error from the previous trials. Subjects returned after a 24-hour period to complete a similar protocol, but beginning with the second context and ending with the first. Interference from the first context on each day caused an increase in initial error for the second (P < 0.05). Following the rest period, subjects showed retention of the sensorimotor memory from the previous day through significantly decreased initial error (P = 3x10-6). However, subjects showed an increase in forces for each new context resulting from a sub-optimal motor strategy. Higher levels of total effort (P < 0.05) and a lack of separation between force values for opposing and non-opposing digits (P > 0.05) indicated a strategy that used more energy to complete the task, even when rates of learning appeared identical or improved. Two possible mechanisms for this lack of energy conservation have been proposed.
ContributorsSmith, Michael David (Author) / Santello, Marco (Thesis director) / Kleim, Jeffrey (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
136820-Thumbnail Image.png
Description
Translating research has been a goal of the Department of Health and Human Services since 1999. Through two years of iteration and interview with our community members, we have collected insights into the barriers to accomplishing this goal. Liberating Science is a think-tank of researchers and scientists who seek to

Translating research has been a goal of the Department of Health and Human Services since 1999. Through two years of iteration and interview with our community members, we have collected insights into the barriers to accomplishing this goal. Liberating Science is a think-tank of researchers and scientists who seek to create a more transparent process to accelerate innovation starting with behavioral health research.
ContributorsRaghani, Pooja Sioux (Author) / Hekler, Eric (Thesis director) / Buman, Matthew (Committee member) / Pruthi, Virgilia Kaur (Committee member) / Barrett, The Honors College (Contributor) / Department of Chemistry and Biochemistry (Contributor) / Biomedical Informatics Program (Contributor)
Created2014-05
Description
This project aims to use the shape memory alloy nitinol as the basis for a biomimetic actuator. These actuators are designed to mimic the behavior of organic muscles for use in prosthetic and robotic devices. Actuator characterization included in the project examines the force output,electrical properties, and other variables relevant

This project aims to use the shape memory alloy nitinol as the basis for a biomimetic actuator. These actuators are designed to mimic the behavior of organic muscles for use in prosthetic and robotic devices. Actuator characterization included in the project examines the force output,electrical properties, and other variables relevant to actuator design.
ContributorsNoe, Cameron Scott (Author) / LaBelle, Jeffrey (Thesis director) / Santello, Marco (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2014-05
137043-Thumbnail Image.png
Description
Over the last decade, the ability to track daily activity through step counting devices has undergone major changes. Advanced technologies have brought about new step counting devices and new form factors. The validity of these new devices is not fully known. The purpose of this study was to

Over the last decade, the ability to track daily activity through step counting devices has undergone major changes. Advanced technologies have brought about new step counting devices and new form factors. The validity of these new devices is not fully known. The purpose of this study was to validate and compare the step counting accuracy of commercially available hip- and wrist-worn accelerometers. A total of 185 participants (18-64 years of age) were analyzed for this study, with the sample composed nearly evenly of each gender (53.5% female) and BMI classification (33% overweight, 31.9% obese). Each participant wore five devices including hip-worn Omron HJ-112 and Fitbit One, and wrist-worn Fitbit Flex, Nike Fuelband, and Jawbone UP. A range of activities (some constant among all participants, some randomly assigned) were then used to accumulate steps including walking on a hard surface for 400m, treadmill walking/running at 2mph, 3mph, and ≥5mph, walking up five flights of stairs, and walking down five flights of stairs. To validate the accuracy of each device, steps were also counted by direct observation. Results showed high concordance with directly observed steps for all devices (intraclass correlation coefficient range: 0.86 to 0.99), with hip-worn devices more accurate than wrist-worn devices. Absolute percent error values were lower among hip-worn devices and at faster walking/running speeds. Nike Fuelband consistently was the worst performing of all test devices. These results are important because as pedometers become more complex, it is important that they remain accurate throughout a variety of activities. Future directions for this research are to explore the validity of these devices in free-living settings and among younger and older populations.
ContributorsKramer, Cody Lee (Author) / Buman, Matthew (Thesis director) / Hoffner, Kristin (Committee member) / Marshall, Simon (Committee member) / Barrett, The Honors College (Contributor) / School of Nutrition and Health Promotion (Contributor)
Created2014-05
137769-Thumbnail Image.png
Description
Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in

Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in Amp i-t, a quantifiable current can be read and the force applied can be calculated. Two common electrochemical techniques in which current is measured, cyclic voltammetry(CV) and amperometric i-t(Amp i-t), were used. A compressible sensor capable of transducing a force and acquiring feedback was created.
ContributorsFeldman, Austin Marc (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Santello, Marco (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137772-Thumbnail Image.png
Description
As robots become more prevalent, the need is growing for efficient yet stable control systems for applications with humans in the loop. As such, it is a challenge for scientists and engineers to develop robust and agile systems that are capable of detecting instability in teleoperated systems. Despite how much

As robots become more prevalent, the need is growing for efficient yet stable control systems for applications with humans in the loop. As such, it is a challenge for scientists and engineers to develop robust and agile systems that are capable of detecting instability in teleoperated systems. Despite how much research has been done to characterize the spatiotemporal parameters of human arm motions for reaching and gasping, not much has been done to characterize the behavior of human arm motion in response to control errors in a system. The scope of this investigation is to investigate human corrective actions in response to error in an anthropomorphic teleoperated robot limb. Characterizing human corrective actions contributes to the development of control strategies that are capable of mitigating potential instabilities inherent in human-machine control interfaces. Characterization of human corrective actions requires the simulation of a teleoperated anthropomorphic armature and the comparison of a human subject's arm kinematics, in response to error, against the human arm kinematics without error. This was achieved using OpenGL software to simulate a teleoperated robot arm and an NDI motion tracking system to acquire the subject's arm position and orientation. Error was intermittently and programmatically introduced to the virtual robot's joints as the subject attempted to reach for several targets located around the arm. The comparison of error free human arm kinematics to error prone human arm kinematics revealed an addition of a bell shaped velocity peak into the human subject's tangential velocity profile. The size, extent, and location of the additional velocity peak depended on target location and join angle error. Some joint angle and target location combinations do not produce an additional peak but simply maintain the end effector velocity at a low value until the target is reached. Additional joint angle error parameters and degrees of freedom are needed to continue this investigation.
ContributorsBevilacqua, Vincent Frank (Author) / Artemiadis, Panagiotis (Thesis director) / Santello, Marco (Committee member) / Trimble, Steven (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2013-05
137739-Thumbnail Image.png
Description
The role of retention and forgetting of context dependent sensorimotor memory of dexterous manipulation was explored. Human subjects manipulated a U-shaped object by switching the handle to be grasped (context) three times, and then came back two weeks later to lift the same object in the opposite context relative to

The role of retention and forgetting of context dependent sensorimotor memory of dexterous manipulation was explored. Human subjects manipulated a U-shaped object by switching the handle to be grasped (context) three times, and then came back two weeks later to lift the same object in the opposite context relative to that experience on the last block. On each context switch, an interference of the previous block of trials was found resulting in manipulation errors (object tilt). However, no significant re-learning was found two weeks later for the first block of trials (p = 0.826), indicating that the previously observed interference among contexts lasted a very short time. Interestingly, upon switching to the other context, sensorimotor memories again interfered with visually-based planning. This means that the memory of lifting in the first context somehow blocked the memory of lifting in the second context. In addition, the performance in the first trial two weeks later and the previous trial of the same context were not significantly different (p = 0.159). This means that subjects are able to retain long-term sensorimotor memories. Lastly, the last four trials in which subjects switched contexts were not significantly different from each other (p = 0.334). This means that the interference from sensorimotor memories of lifting in opposite contexts was weaker, thus eventually leading to the attainment of steady performance.
ContributorsGaw, Nathan Benjamin (Author) / Santello, Marco (Thesis director) / Helms Tillery, Stephen (Committee member) / Buneo, Christopher (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137748-Thumbnail Image.png
Description
I worked on the human-machine interface to improve human physical capability. This work was done in the Human Oriented Robotics and Control Lab (HORC) towards the creation of an advanced, EMG-controlled exoskeleton. The project was new, and any work on the human- machine interface needs the physical interface itself. So

I worked on the human-machine interface to improve human physical capability. This work was done in the Human Oriented Robotics and Control Lab (HORC) towards the creation of an advanced, EMG-controlled exoskeleton. The project was new, and any work on the human- machine interface needs the physical interface itself. So I designed and fabricated a human-robot coupling device with a novel safety feature. The validation testing of this coupling proved very successful, and the device was granted a provisional patent as well as published to facilitate its spread to other human-machine interface applications, where it could be of major benefit. I then employed this coupling in experimentation towards understanding impedance, with the end goal being the creation of an EMG-based impedance exoskeleton control system. I modified a previously established robot-to-human perturbation method for use in my novel, three- dimensional (3D) impedance measurement experiment. Upon execution of this experiment, I was able to successfully characterize passive, static human arm stiffness in 3D, and in doing so validated the aforementioned method. This establishes an important foundation for promising future work on understanding impedance and the creation of the proposed control scheme, thereby furthering the field of human-robot interaction.
ContributorsO'Neill, Gerald D. (Author) / Artemiadis, Panagiotis (Thesis director) / Santello, Marco (Committee member) / Santos, Veronica (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2013-05