Methods: Participants were recruited from the parent REasons for Geographic and Racial Differences in Stroke (REGARDS) Study. ActicalTM accelerometers provided estimates of PA variables, including moderate-to-vigorous PA (MVPA), high light PA (HLPA), low light PA (LLPA) and sedentary time, for 4-7 consecutive days. Prevalence and incidence of cognitive impairment were defined by the Six-Item Screener. Letter fluency, animal fluency, word list learning and Montreal Cognitive Assessment (orientation and recall) were conducted to assess executive function and memory.
Results: Of the 7,339 participants who provided accelerometer wear data > 4 days (70.1 ± 8.6 yr, 54.2% women, 31.7% African American), 320 participants exhibited impaired cognition. In cross-sectional analysis, participants in the highest MVPA% quartile had 39% lower odds of cognitive impairment than those in the lowest quartile (OR: 0.61, 95% C.I.: 0.39-0.95) after full adjustment. Further analysis shows most quartiles of MVPA% and HLPA% were significantly associated with executive function and memory (P<0.01). During 2.7 ± 0.5 years of follow-up, 3,385 participants were included in the longitudinal analysis, with 157 incident cases of cognitive impairment. After adjustments, participants in the highest MVPA% quartile had 51% lower hazards of cognitive impairment (HR: 0.49, 95% C.I.: 0.28-0.86). Additionally, MVPA% was inversely associated with change in memory z-scores (P<0.01), while the highest quartile of HLPA% was inversely associated with change in executive function and memory z-scores (P<0.01).
Conclusion: Higher levels of objectively measured MVPA% were independently associated with lower prevalence and incidence of cognitive impairment, and better memory and executive function in older adults. Higher levels of HLPA% were also independently associated with better memory and executive function. The amount of MVPA associated with lower risk of cognitive impairment (259 min/week) is >70% higher than the minimal amount of MVPA recommended by PA guidelines.
Vegetarian diets are typically more sustainable than omnivorous ones due to using less environmental resources in the production of food. An important consideration with plant protein and vegetarian diets, however, is whether this would affect athletic performance. To examine this, 70 male and female endurance athletes were compared for maximal oxygen uptake (VO2 max), peak torque when doing leg extensions, and body composition. Vegetarians had higher VO2 max, but peak torque was not significantly different by diet. Omnivores had higher total body mass, lean body mass, and there was a trend for peak torque to be higher.
To investigate whether plant-protein can comparably support development of lean body mass and strength development in conjunction with strength training, 61 healthy young males and females began a 12-week training and protein supplementation study. While previous training studies have shown no differences for lean body mass or strength development when consuming either soy (plant) or whey (animal) protein supplements in very large amounts (>48 grams), when consuming around 15-20 grams, whey has contributed to greater lean body mass accrual, although strength increases remain similar. The present study matched supplements by leucine content instead of by total protein amount since leucine has been shown to be a key stimulator of muscle protein synthesis and is more concentrated in animal protein. There were no significant differences between the whey or soy group for lean body mass or strength development, as assessed using isokinetic dynamometry doing leg extensions and flexions.
We present results from experiments at the Linac Coherent Light Source (LCLS) demonstrating that serial femtosecond crystallography (SFX) can be performed to high resolution (~2.5 Å) using protein microcrystals deposited on an ultra-thin silicon nitride membrane and embedded in a preservation medium at room temperature. Data can be acquired at a high acquisition rate using x-ray free electron laser sources to overcome radiation damage, while sample consumption is dramatically reduced compared to flowing jet methods. We achieved a peak data acquisition rate of 10 Hz with a hit rate of ~38%, indicating that a complete data set could be acquired in about one 12-hour LCLS shift using the setup described here, or in even less time using hardware optimized for fixed target SFX. This demonstration opens the door to ultra low sample consumption SFX using the technique of diffraction-before-destruction on proteins that exist in only small quantities and/or do not produce the copious quantities of microcrystals required for flowing jet methods.
Membrane proteins are key players in biological systems, mediating signalling events and the specific transport of e.g. ions and metabolites. Consequently, membrane proteins are targeted by a large number of currently approved drugs. Understanding their functions and molecular mechanisms is greatly dependent on structural information, not least on complexes with functionally or medically important ligands. Structure determination, however, is hampered by the difficulty of obtaining well diffracting, macroscopic crystals. Here, the feasibility of X-ray free-electron-laser-based serial femtosecond crystallography (SFX) for the structure determination of membrane protein-ligand complexes using microcrystals of various native-source and recombinant P-type ATPase complexes is demonstrated. The data reveal the binding sites of a variety of ligands, including lipids and inhibitors such as the hallmark P-type ATPase inhibitor orthovanadate. By analyzing the resolution dependence of ligand densities and overall model qualities, SFX data quality metrics as well as suitable refinement procedures are discussed. Even at relatively low resolution and multiplicity, the identification of ligands can be demonstrated. This makes SFX a useful tool for ligand screening and thus for unravelling the molecular mechanisms of biologically active proteins.
Background: The Nike + Fuelband is a commercially available, wrist-worn accelerometer used to track physical activity energy expenditure (PAEE) during exercise. However, validation studies assessing the accuracy of this device for estimating PAEE are lacking. Therefore, this study examined the validity and reliability of the Nike + Fuelband for estimating PAEE during physical activity in young adults. Secondarily, we compared PAEE estimation of the Nike + Fuelband with the previously validated SenseWear Armband (SWA).
Methods: Twenty-four participants (n = 24) completed two, 60-min semi-structured routines consisting of sedentary/light-intensity, moderate-intensity, and vigorous-intensity physical activity. Participants wore a Nike + Fuelband and SWA, while oxygen uptake was measured continuously with an Oxycon Mobile (OM) metabolic measurement system (criterion).
Results: The Nike + Fuelband (ICC = 0.77) and SWA (ICC = 0.61) both demonstrated moderate to good validity. PAEE estimates provided by the Nike + Fuelband (246 ± 67 kcal) and SWA (238 ± 57 kcal) were not statistically different than OM (243 ± 67 kcal). Both devices also displayed similar mean absolute percent errors for PAEE estimates (Nike + Fuelband = 16 ± 13 %; SWA = 18 ± 18 %). Test-retest reliability for PAEE indicated good stability for Nike + Fuelband (ICC = 0.96) and SWA (ICC = 0.90).
Conclusion: The Nike + Fuelband provided valid and reliable estimates of PAEE, that are similar to the previously validated SWA, during a routine that included approximately equal amounts of sedentary/light-, moderate- and vigorous-intensity physical activity.
Background: Little research has explored who responds better to an automated vs. human advisor for health behaviors in general, and for physical activity (PA) promotion in particular. The purpose of this study was to explore baseline factors (i.e., demographics, motivation, interpersonal style, and external resources) that moderate intervention efficacy delivered by either a human or automated advisor.
Methods: Data were from the CHAT Trial, a 12-month randomized controlled trial to increase PA among underactive older adults (full trial N = 218) via a human advisor or automated interactive voice response advisor. Trial results indicated significant increases in PA in both interventions by 12 months that were maintained at 18-months. Regression was used to explore moderation of the two interventions.
Results: Results indicated amotivation (i.e., lack of intent in PA) moderated 12-month PA (d = 0.55, p < 0.01) and private self-consciousness (i.e., tendency to attune to one’s own inner thoughts and emotions) moderated 18-month PA (d = 0.34, p < 0.05) but a variety of other factors (e.g., demographics) did not (p > 0.12).
Conclusions: Results provide preliminary evidence for generating hypotheses about pathways for supporting later clinical decision-making with regard to the use of either human- vs. computer-delivered interventions for PA promotion.