Matching Items (122)
193383-Thumbnail Image.png
Description
For cold chain tracking systems, precision and versatility across varying time intervals and temperature ranges remain integral to effective application in clinical, commercial, and academic settings. Therefore, while electronic and chemistry/physics based cold chain tracking mechanisms currently exist, both have limitations that affect their application across various biospecimens and commercial

For cold chain tracking systems, precision and versatility across varying time intervals and temperature ranges remain integral to effective application in clinical, commercial, and academic settings. Therefore, while electronic and chemistry/physics based cold chain tracking mechanisms currently exist, both have limitations that affect their application across various biospecimens and commercial products, providing the initiative to develop a time temperature visual indicator system that resolves challenges with current cold chain tracking approaches. As a result, a permanganate/oxalic acid time temperature visual indicator system for cold chain tracking has been proposed. At thawing temperatures, the designed permanganate/oxalic acid reaction system undergoes a pink to colorless transition as permanganate, Mn(VII), is reduced to auto-catalytic Mn(II), while oxalate is oxidized to CO2. Therefore, when properly stored and vitrified or frozen, the proposed visual indicator remains pink, whereas exposure to thawing conditions will result in an eventual, time temperature dependent, designed color transition that characterizes compromised biospecimen integrity. To design visual indicator systems for targeted times at specific temperatures, absorbance spectroscopy was utilized to monitor permanganate kinetic curves by absorbance at 525 nm. As a result, throughout the outlined research, the following aims were demonstrated: (i) Design and functionality of 1x (0.5 mM KMnO4) visual indicator systems across various time intervals at temperatures ranging from 25°C to -20°C, (ii) Design and functionality of high concentration, 5x, visual indicator systems across varying targeted time intervals at temperatures ranging from 25°C to 0°C, (iii) Pre-activation stability and long-term stability of the proposed visual indicator systems.
ContributorsLjungberg, Emil (Author) / Borges, Chad (Thesis advisor) / Levitus, Marcia (Committee member) / Williams, Peter (Committee member) / Arizona State University (Publisher)
Created2024
193377-Thumbnail Image.png
Description
Insulator-based dielectrophoresis (iDEP) has attracted considerable attention due to its ability to precisely capture and manipulate nanoparticles and biomolecules. A distinctive approach for effective manipulation of nanometer-sized proteins employing iDEP technique by generating higher electric field (E) and gradient (??2) in the iDEP microfluidic devices is delineated. Strategies to generate

Insulator-based dielectrophoresis (iDEP) has attracted considerable attention due to its ability to precisely capture and manipulate nanoparticles and biomolecules. A distinctive approach for effective manipulation of nanometer-sized proteins employing iDEP technique by generating higher electric field (E) and gradient (??2) in the iDEP microfluidic devices is delineated. Strategies to generate higher ??2 in the iDEP devices were outlined using numerical simulations. Intriguingly, the numerical simulation results demonstrated that by decreasing the post-to-post gap in the iDEP microfluidic devices, the ??2 was increased by ⁓12 fold. Furthermore, the inclusion of channel constrictions, such as rectangular constriction or curved constriction into the straight channel iDEP microfluidic device led to a significant increase in ??2. In addition, the inclusion of rectangular constrictions in the straight channel iDEP microfluidic device resulted in a greater increase in ??2 compared to the incorporation of curved constrictions in the same device. Moreover, the straight channel device with horizontal post-to-post gap of 20 μm and vertical post-to-post gap of 10 μm generated the lowest ??2 and the ??2 was uniform across the device. The rectangular constriction device with horizontal and vertical post-to-post gap of 5 μm generated the highest ??2 and the ??2 was non-uniform across the device. Subsequently, suitable candidate devices were fabricated using soft lithography as well as high resolution 3D printing and the DEP behavior of ferritin examined under various experimental conditions. Positive streaming DEP could be observed for ferritin at low frequency in the device generating the lowest ??2, whereas at higher frequency of 10 kHz no DEP trapping characteristics were apparent in the same device. Importantly, in the device geometry resulting in the highest ??2 at 10 kHz, labeled ferritin exhibited pDEPtrapping characteristics. This is an indication that the DEP force superseded diffusion and became the dominant force.
ContributorsMAHMUD, SAMIRA (Author) / Ros, Alexandra (Thesis advisor) / Borges, Chad (Committee member) / Mills, Jeremy (Committee member) / Arizona State University (Publisher)
Created2024
193014-Thumbnail Image.png
Description
The consequences of failures from large-diameter water pipelines can be severe. Results can include significant property damage, damage to adjacent infrastructure such as roads and bridges resulting in transportation delays or shutdowns, adjacent structural damage to buildings resulting in loss of business, service disruption to a significant number of

The consequences of failures from large-diameter water pipelines can be severe. Results can include significant property damage, damage to adjacent infrastructure such as roads and bridges resulting in transportation delays or shutdowns, adjacent structural damage to buildings resulting in loss of business, service disruption to a significant number of customers, loss of water, costly emergency repairs, and even loss of life. The American Water Works Association’s (AWWA) 2020 “State of the Water Industry” report states the top issue facing the water industry since 2016 is aging infrastructure, with the second being financing for improvements. The industry must find innovative ways to extend asset life and reduce maintenance expenditures. While are many different assets comprise the drinking water industry, pipelines are a major component and often neglected because they are typically buried. Reliability Centered Maintenance (RCM) is a process used to determine the most effective maintenance strategy for an asset, with the ultimate goal being to establish the required function of the asset with the required reliability at the lowest operations and maintenance costs. The RCM philosophy considers Preventive Maintenance, Predictive Maintenance, Condition Based Monitoring, Reactive Maintenance, and Proactive Maintenance techniques in an integrated manner to increase the probability an asset will perform its designed function throughout its design life with minimal maintenance. In addition to determining maintenance tasks, the timely performance of those tasks is crucial. If performed too late an asset may fail; if performed too early, resources that may be used better elsewhere are expended. Utility agencies can save time and money by using RCM analysis for their drinking water infrastructure. This dissertation reviews industries using RCM, discusses the benefits of an RCM analysis, and goes through a case study of an RCM at a large aqueduct in the United States. The dissertation further discusses the consequence of failure of large diameter water pipelines and proposes a regression model to help agencies determine the optimum time to perform maintenance tasks on large diameter prestressed concrete pipelines using RCM analysis.
ContributorsGeisbush, James R (Author) / Ariaratnam, Samuel T (Thesis advisor) / Grau, David (Committee member) / Chong, Oswald (Committee member) / Arizona State University (Publisher)
Created2024
Description
Background: Eosinophilic esophagitis (EoE) is an increasingly prevalent allergic disease characterized by eosinophilic inflammation and symptoms of esophageal dysfunction. Diagnosis and monitoring require repeated, invasive endoscopic esophageal biopsies to assess levels of eosinophilic inflammation. Recently, the minimally invasive esophageal string test (EST) has been used collect protein in mucosal secretions

Background: Eosinophilic esophagitis (EoE) is an increasingly prevalent allergic disease characterized by eosinophilic inflammation and symptoms of esophageal dysfunction. Diagnosis and monitoring require repeated, invasive endoscopic esophageal biopsies to assess levels of eosinophilic inflammation. Recently, the minimally invasive esophageal string test (EST) has been used collect protein in mucosal secretions as a surrogate for tissue biopsies in monitoring disease activity. From the string, assessment of the eosinophil-associated proteins major basic protein-1 (MBP-1) and eotaxin-3 (Eot3) is used to assess disease activity; however, this requires measurement in a reference laboratory, for which the turnaround time for results exceeds the time required for histopathologic assessment of endoscopic biopsies. In addition, MBP-1 and Eot3 are not markers unique to eosinophils. These obstacles can be overcome by targeting eosinophil peroxidase (EPX), an eosinophil-specific protein, using a rapid point-of-care test. Currently, EPX is measured by a labor-intensive enzyme-linked immunosorbent assay (ELISA), but we sought to optimize a rapid point-of-care test to measure EPX in EST segments. Methods: We extracted protein from residual EST segments and measured EPX levels by ELISA and a lateral flow assay (LFA). Results: EPX levels measured by LFA strongly correlated with those quantified by ELISA (rs = 0.90 {95% CI: 0.8283, 0.9466}). The EPX LFA is comparable to ELISA for measuring EPX levels in ESTs. Conclusions: The EPX LFA can provide a way to rapidly test EPX levels in ESTs in clinical settings and may serve as a valuable tool to facilitate diagnosis and monitoring of EoE.
ContributorsDao, Adelyn (Author) / Lake, Douglas (Thesis director) / Borges, Chad (Committee member) / Wright, Benjamin (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor) / School of Life Sciences (Contributor)
Created2024-05
193394-Thumbnail Image.png
Description
Alzheimer’s Disease (AD) is the most common form of dementia affecting the population over the age of 65. AD is characterized clinically by increasing difficulty with memory and language, resulting in a loss of independence. This is due to the presence of two characteristic protein aggregates in the brain: extracellular

Alzheimer’s Disease (AD) is the most common form of dementia affecting the population over the age of 65. AD is characterized clinically by increasing difficulty with memory and language, resulting in a loss of independence. This is due to the presence of two characteristic protein aggregates in the brain: extracellular amyloid plaques and intracellular neurofibrillary tangles (NFTs). Utilizing multiplexed immunofluorescence and dimensional reduction analysis the types of cells present in the hippocampus, the region of the brain most affected by AD, can be explored. Understanding the kinds of cell subtypes present, the mechanism behind how AD develops can be explored. Multiplexed IF was performed on human hippocampus FFPE tissues to detect a total of 37 proteins. Dimensional reduction analysis was performed to identify the four major cell types in the brain: neurons, oligodendrocytes, astrocytes, and microglia. After identifying each cell type, further dimensional reduction analysis was performed within each cell type to identify cell subtypes. A total of 21 neuron, 41 oligodendrocyte, 20 astrocyte, and 22 microglia subtypes were identified. The location of cell subtypes in each region of the hippocampal formation was found to match previous reports, further validating the findings of this project.
ContributorsEllison, Mischa A (Author) / Guo, Jia (Thesis advisor) / Borges, Chad (Committee member) / Mastroeni, Diego (Committee member) / Arizona State University (Publisher)
Created2024
165221-Thumbnail Image.png
Description
With needs for carbon sequestration and sustainable chemical feedstocks increasing formate stands out as a real possibility in addressing these growing problems. One of the principal issues with positioning formate as the central compound of a bioeconomy is establishing a sustainable and reliable method for producing it. The goal of

With needs for carbon sequestration and sustainable chemical feedstocks increasing formate stands out as a real possibility in addressing these growing problems. One of the principal issues with positioning formate as the central compound of a bioeconomy is establishing a sustainable and reliable method for producing it. The goal of this project was to take the first steps towards engineering a formate production cell factory in Chlamydomonas reinhardtii by introducing the biosynthetic pathway necessary for the creation of molybdenum cofactor which would later be used as an integral part of the function of a formate dehydrogenase enzyme capable of reducing carbon dioxide to make formate. I was able to get some seemingly successful transformants but unable to confidently confirm whether or not these transformants hardboard the molybdenum cofactor synthesis genes.
ContributorsNikkel, Zachary (Author) / Redding, Kevin (Thesis director) / Ghirlanda, Giovanna (Committee member) / Borges, Chad (Committee member) / Barrett, The Honors College (Contributor) / School of Molecular Sciences (Contributor)
Created2022-05
187379-Thumbnail Image.png
Description
The world faces significant environmental and social challenges due to high economic development, population growth, industrialization, rapid urbanization, and unsustainable consumption. Global communities are taking the necessary measures to confront these international challenges and applying sustainable development principles across all sectors. Construction is a critical driving instrument of economic activity,

The world faces significant environmental and social challenges due to high economic development, population growth, industrialization, rapid urbanization, and unsustainable consumption. Global communities are taking the necessary measures to confront these international challenges and applying sustainable development principles across all sectors. Construction is a critical driving instrument of economic activity, and to achieve sustainable development, it is vital to transform conventional construction into a more sustainable model. The research investigated sustainable construction perceptions in Kuwait, a rapidly growing country with a high volume of construction activities. Kuwait has ambitious plans to transition into a more sustainable economic development model, and the construction industry needs to align with these plans. This research aims to identify the characteristics of sustainable construction applications in the Kuwaiti construction market, such as awareness, current perceptions, drivers and barriers, and the construction regulations' impact. The research utilized a qualitative approach to answer research questions and deliver research objectives by conducting eleven Semi-structured interviews with experienced professionals in the Kuwaiti construction market to collect rich data that reflects insights and understandings of the Kuwaiti construction industry. The Thematic analysis of the data resulted in six themes and one sub-theme that presented reflections, insights, and perspectives on sustainable construction perceptions in the Kuwaiti construction market. The research findings reflected poor sustainable construction awareness and poor environmental and social application in the construction industry, the determinant role of construction regulations in promoting sustainable construction. and barriers and drivers to sustainable construction applications. The research concluded with answers to research questions, delivery of research objectives, and an explanation of sustainable construction perceptions in the Kuwaiti construction market.
Contributorsalsalem, mohammad salem (Author) / Duran, Melanie (Thesis advisor) / Chong, Oswald (Committee member) / Sullivan, Kenneth (Committee member) / Grau, David (Committee member) / Arizona State University (Publisher)
Created2023
187709-Thumbnail Image.png
Description
During the rapid growth of infrastructure projects globally, countries pay high environmental and social costs as a result of the impacts caused from utilizing the traditional open-cut utility installation method that still widely being used in Egypt. For that, it was essential to have alternatives to reduce these environmental impacts

During the rapid growth of infrastructure projects globally, countries pay high environmental and social costs as a result of the impacts caused from utilizing the traditional open-cut utility installation method that still widely being used in Egypt. For that, it was essential to have alternatives to reduce these environmental impacts and social costs; however, there are some obstacles that prevent the implementation and the realization of these alternatives.This research is conducted mainly to evaluate the environmental impacts of open-cut excavation vs. trenchless technology in Egypt, through two main methodologies. Firstly, a field survey that aims to measure knowledge of people working in the Egyptian construction industry of trenchless technology, and the harms caused from keeping utilizing open-cut for installing all kinds of underground utilities. In addition to investigating the reasons behind not relying on trenchless technology as a safe alternative for open-cut in Egypt. Furthermore, in order to compare the greenhouse gases emissions resulted from both open-cut vs trenchless technology, a real case study is applied quantifying the amounts of the resulted greenhouse gases from each method. The results show that greenhouse gases emissions generated from open-cut were extremely higher than that of horizontal directional drilling as a trenchless installation method.
ContributorsKhedr, Ahmed Mossad Saeed Hafez (Author) / Ariaratnam, Samuel (Thesis advisor) / El Asmar, Mounir (Committee member) / Chong, Oswald (Committee member) / Arizona State University (Publisher)
Created2023
156842-Thumbnail Image.png
Description
Most drugs work by binding to receptors on the cell surface. These receptors can then carry the message into the cell and have a wide array of results. However, studying how fast the binding is can be difficult. Current methods involve extracting the receptor and labeling them, but both these

Most drugs work by binding to receptors on the cell surface. These receptors can then carry the message into the cell and have a wide array of results. However, studying how fast the binding is can be difficult. Current methods involve extracting the receptor and labeling them, but both these steps have issues. Previous works found that binding on the cell surface is accompanied with a small change in cell size, generally an increase. They have also developed an algorithm that can track these small changes without a label using a simple bright field microscope. Here, this relationship is further explored by comparing edge tracking results to a more widely used method, surface plasmon resonance. The kinetic constants found from the two methods are in agreement. No corrections or manipulations were needed to create agreement. The Bland-Altman plots shows that the error between the two methods is about 0.009 s-1. This is about the same error between cells, making it a non-dominant source of error.
ContributorsHunt, Ashley (Author) / Tao, Nongjian (Thesis advisor) / Ros, Alexandra (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2018
156784-Thumbnail Image.png
Description
Measuring molecular interaction with membrane proteins is critical for understanding cellular functions, validating biomarkers and screening drugs. Despite the importance, developing such a capability has been a difficult challenge, especially for small molecules binding to membrane proteins in their native cellular environment. The current mainstream practice is to isolate membrane

Measuring molecular interaction with membrane proteins is critical for understanding cellular functions, validating biomarkers and screening drugs. Despite the importance, developing such a capability has been a difficult challenge, especially for small molecules binding to membrane proteins in their native cellular environment. The current mainstream practice is to isolate membrane proteins from the cell membranes, which is difficult and often lead to the loss of their native structures and functions. In this thesis, novel detection methods for in situ quantification of molecular interactions with membrane proteins are described.

First, a label-free surface plasmon resonance imaging (SPRi) platform is developed for the in situ detection of the molecular interactions between membrane protein drug target and its specific antibody drug molecule on cell surface. With this method, the binding kinetics of the drug-target interaction is quantified for drug evaluation and the receptor density on the cell surface is also determined.

Second, a label-free mechanically amplification detection method coupled with a microfluidic device is developed for the detection of both large and small molecules on single cells. Using this method, four major types of transmembrane proteins, including glycoproteins, ion channels, G-protein coupled receptors (GPCRs) and tyrosine kinase receptors on single whole cells are studied with their specific drug molecules. The basic principle of this method is established by developing a thermodynamic model to express the binding-induced nanometer-scale cellular deformation in terms of membrane protein density and cellular mechanical properties. Experiments are carried out to validate the model.

Last, by tracking the cell membrane edge deformation, molecular binding induced downstream event – granule exocytosis is measured with a dual-optical imaging system. Using this method, the single granule exocytosis events in single cells are monitored and the temporal-spatial distribution of the granule fusion-induced cell membrane deformation are mapped. Different patterns of granule release are resolved, including multiple release events occurring close in time and position. The label-free cell membrane deformation tracking method was validated with the simultaneous fluorescence recording. And the simultaneous cell membrane deformation detection and fluorescence recording allow the study of the propagation of the granule release-induced membrane deformation along cell surfaces.
ContributorsZhang, Fenni (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Borges, Chad (Committee member) / Jing, Tianwei (Committee member) / Wang, Shaopeng (Committee member) / Arizona State University (Publisher)
Created2018