Matching Items (339)
150020-Thumbnail Image.png
Description
Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would

Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would improve dietary self-monitoring over the traditional paper-and-pencil method. The study also looked at whether the difference in methods would affect weight loss. Forty-seven adults (BMI 25 to 40 kg/m2) completed an 8-week study focused on tracking the difference in adherence to a self-monitoring protocol and subsequent weight loss. Participants owning iPhones (n=17) used the 'Lose It' application (AP) for diet and exercise tracking and were compared to smartphone participants who recorded dietary intake using a memo (ME) feature (n=15) on their phone and participants using the traditional paper-and-pencil (PA) method (n=15). There was no significant difference in completion rates between groups with an overall completion rate of 85.5%. The overall mean adherence to self-monitoring for the 8-week period was better in the AP group than the PA group (p = .024). No significant difference was found between the AP group and ME group (p = .148), or the ME group and the PA group (p = .457). Weight loss for the 8 week study was significant for all groups (p = .028). There was no significant difference in weight loss between groups. Number of days recorded regardless of group assignment showed a weak correlation to weight loss success (p = .068). Smartphone owners seeking to lose weight should be encouraged by the potential success associated with dietary tracking using a smartphone app as opposed to the traditional paper-and-pencil method.
ContributorsCunningham, Barbara (Author) / Wharton, Christopher (Christopher Mack), 1977- (Thesis advisor) / Johnston, Carol (Committee member) / Hall, Richard (Committee member) / Arizona State University (Publisher)
Created2012
150024-Thumbnail Image.png
Description
Chemical and mineralogical data from Mars shows that the surface has been chemically weathered on local to regional scales. Chemical trends and the types of chemical weathering products present on the surface and their abundances can elucidate information about past aqueous processes. Thermal-infrared (TIR) data and their respective models are

Chemical and mineralogical data from Mars shows that the surface has been chemically weathered on local to regional scales. Chemical trends and the types of chemical weathering products present on the surface and their abundances can elucidate information about past aqueous processes. Thermal-infrared (TIR) data and their respective models are essential for interpreting Martian mineralogy and geologic history. However, previous studies have shown that chemical weathering and the precipitation of fine-grained secondary silicates can adversely affect the accuracy of TIR spectral models. Furthermore, spectral libraries used to identify minerals on the Martian surface lack some important weathering products, including poorly-crystalline aluminosilicates like allophane, thus eliminating their identification in TIR spectral models. It is essential to accurately interpret TIR spectral data from chemically weathered surfaces to understand the evolution of aqueous processes on Mars. Laboratory experiments were performed to improve interpretations of TIR data from weathered surfaces. To test the accuracy of deriving chemistry of weathered rocks from TIR spectroscopy, chemistry was derived from TIR models of weathered basalts from Baynton, Australia and compared to actual weathering rind chemistry. To determine how specific secondary silicates affect the TIR spectroscopy of weathered basalts, mixtures of basaltic minerals and small amounts of secondary silicates were modeled. Poorly-crystalline aluminosilicates were synthesized and their TIR spectra were added to spectral libraries. Regional Thermal Emission Spectrometer (TES) data were modeled using libraries containing these poorly-crystalline aluminosilicates to test for their presence on the Mars. Chemistry derived from models of weathered Baynton basalts is not accurate, but broad chemical weathering trends can be interpreted from the data. TIR models of mineral mixtures show that small amounts of crystalline and amorphous silicate weathering products (2.5-5 wt.%) can be detected in TIR models and can adversely affect modeled plagioclase abundances. Poorly-crystalline aluminosilicates are identified in Northern Acidalia, Solis Planum, and Meridiani. Previous studies have suggested that acid sulfate weathering was the dominant surface alteration process for the past 3.5 billion years; however, the identification of allophane indicates that alteration at near-neutral pH occurred on regional scales and that acid sulfate weathering is not the only weathering process on Mars.
ContributorsRampe, Elizabeth Barger (Author) / Sharp, Thomas G (Thesis advisor) / Christensen, Phillip (Committee member) / Hervig, Richard (Committee member) / Shock, Everett (Committee member) / Williams, Lynda (Committee member) / Arizona State University (Publisher)
Created2011
150036-Thumbnail Image.png
Description
Demand for biosensor research applications is growing steadily. According to a new report by Frost & Sullivan, the biosensor market is expected to reach $14.42 billion by 2016. Clinical diagnostic applications continue to be the largest market for biosensors, and this demand is likely to continue through 2016 and beyond.

Demand for biosensor research applications is growing steadily. According to a new report by Frost & Sullivan, the biosensor market is expected to reach $14.42 billion by 2016. Clinical diagnostic applications continue to be the largest market for biosensors, and this demand is likely to continue through 2016 and beyond. Biosensor technology for use in clinical diagnostics, however, requires translational research that moves bench science and theoretical knowledge toward marketable products. Despite the high volume of academic research to date, only a handful of biomedical devices have become viable commercial applications. Academic research must increase its focus on practical uses for biosensors. This dissertation is an example of this increased focus, and discusses work to advance microfluidic-based protein biosensor technologies for practical use in clinical diagnostics. Four areas of work are discussed: The first involved work to develop reusable/reconfigurable biosensors that are useful in applications like biochemical science and analytical chemistry that require detailed sensor calibration. This work resulted in a prototype sensor and an in-situ electrochemical surface regeneration technique that can be used to produce microfluidic-based reusable biosensors. The second area of work looked at non-specific adsorption (NSA) of biomolecules, which is a persistent challenge in conventional microfluidic biosensors. The results of this work produced design methods that reduce the NSA. The third area of work involved a novel microfluidic sensing platform that was designed to detect target biomarkers using competitive protein adsorption. This technique uses physical adsorption of proteins to a surface rather than complex and time-consuming immobilization procedures. This method enabled us to selectively detect a thyroid cancer biomarker, thyroglobulin, in a controlled-proteins cocktail and a cardiovascular biomarker, fibrinogen, in undiluted human serum. The fourth area of work involved expanding the technique to produce a unique protein identification method; Pattern-recognition. A sample mixture of proteins generates a distinctive composite pattern upon interaction with a sensing platform consisting of multiple surfaces whereby each surface consists of a distinct type of protein pre-adsorbed on the surface. The utility of the "pattern-recognition" sensing mechanism was then verified via recognition of a particular biomarker, C-reactive protein, in the cocktail sample mixture.
ContributorsChoi, Seokheun (Author) / Chae, Junseok (Thesis advisor) / Tao, Nongjian (Committee member) / Yu, Hongyu (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
150048-Thumbnail Image.png
Description
A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene,

A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene, and xylenes (BTEX) via a homemade molecular imprinted polymer, and a specific detection and control circuit. The device is a wireless, portable, battery-powered, and cell-phone operated device. The device has been calibrated and validated in the laboratory and using selected ion flow tube mass spectrometry (SFIT-MS). The capability and robustness are also demonstrated in some field tests. It provides rapid and reliable detection of BTEX in real samples, including challenging high concentrations of interferents, and it is suitable for occupational, environmental health and epidemiological applications.
ContributorsChen, Zheng (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
149677-Thumbnail Image.png
Description
Applications of non-traditional stable isotope variations are moving beyond geosciences to biomedicine, made possible by advances in multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) technology. Mass-dependent isotope variation can provide information about the sources of elements and the chemical reactions that they undergo. Iron and calcium isotope systematics in

Applications of non-traditional stable isotope variations are moving beyond geosciences to biomedicine, made possible by advances in multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) technology. Mass-dependent isotope variation can provide information about the sources of elements and the chemical reactions that they undergo. Iron and calcium isotope systematics in biomedicine are relatively unexplored but have great potential scientific interest due to their essential nature in metabolism. Iron, a crucial element in biology, fractionates during biochemically relevant reactions. To test the extent of this fractionation in an important reaction process, equilibrium iron isotope fractionation during organic ligand exchange was determined. The results show that iron fractionates during organic ligand exchange, and that isotope enrichment increases as a function of the difference in binding constants between ligands. Additionally, to create a mass balance model for iron in a whole organism, iron isotope compositions in a whole mouse and in individual mouse organs were measured. The results indicate that fractionation occurs during transfer between individual organs, and that the whole organism was isotopically light compared with food. These two experiments advance our ability to interpret stable iron isotopes in biomedicine. Previous research demonstrated that calcium isotope variations in urine can be used as an indicator of changes in net bone mineral balance. In order to measure calcium isotopes by MC-ICP-MS, a chemical purification method was developed to quantitatively separate calcium from other elements in a biological matrix. Subsequently, this method was used to evaluate if calcium isotopes respond when organisms are subjected to conditions known to induce bone loss: 1) Rhesus monkeys were given an estrogen-suppressing drug; 2) Human patients underwent extended bed rest. In both studies, there were rapid, detectable changes in calcium isotope compositions from baseline - verifying that calcium isotopes can be used to rapidly detect changes in bone mineral balance. By characterizing iron isotope fractionation in biologically relevant processes and by demonstrating that calcium isotopes vary rapidly in response to bone loss, this thesis represents an important step in utilizing these isotope systems as a diagnostic and mechanistic tool to study the metabolism of these elements in vivo.
ContributorsMorgan, Jennifer Lynn Louden (Author) / Anbar, Ariel D. (Thesis advisor) / Wasylenki, Laura E. (Committee member) / Jones, Anne K. (Committee member) / Shock, Everett (Committee member) / Arizona State University (Publisher)
Created2011
149777-Thumbnail Image.png
Description
Nut consumption, specifically almonds, have been shown to help maintain weight and influence disease risk factors in adult populations. Limited studies have been conducted examining the effect of a small dose of almonds on energy intake and body weight. The objective of this study was to determine the influence of

Nut consumption, specifically almonds, have been shown to help maintain weight and influence disease risk factors in adult populations. Limited studies have been conducted examining the effect of a small dose of almonds on energy intake and body weight. The objective of this study was to determine the influence of pre-meal almond consumption on energy intake and weight in overweight and obese adults. In this study included 21, overweight or obese, participants who were considered healthy or had a controlled disease state. This 8-week parallel arm study, participants were randomized to consume an isocaloric amount of almonds, (1 oz) serving, or two (2 oz) cheese stick serving, 30 minutes before the dinner meal, 5 times per week. Anthropometric measurements including weight, waist circumference, and body fat percentage were recorded at baseline, week 1, 4, and 8. Measurement of energy intake was self-reported for two consecutive days at week 1, 4 and 8 using the ASA24 automated dietary program. The energy intake after 8 weeks of almond consumption was not significantly different when compared to the control group (p=0.965). In addition, body weight was not significantly reduced after 8 weeks of the almond intervention (p=0.562). Other parameters measured in this 8-week trial did not differ between the intervention and the control group. These data presented are underpowered and therefore inconclusive on the effects that 1 oz of almonds, in the diet, 5 per week has on energy intake and bodyweight.
ContributorsMcBride, Lindsey (Author) / Johnston, Carol (Thesis advisor) / Swan, Pamela (Committee member) / Mayol-Kreiser, Sandra (Committee member) / Arizona State University (Publisher)
Created2011
149647-Thumbnail Image.png
Description
This thesis describes several approaches to next generation DNA sequencing via tunneling current method based on a Scanning Tunneling Microscope system. In chapters 5 and 6, preliminary results have shown that DNA bases could be identified by their characteristic tunneling signals. Measurements taken in aqueous buffered solution showed that single

This thesis describes several approaches to next generation DNA sequencing via tunneling current method based on a Scanning Tunneling Microscope system. In chapters 5 and 6, preliminary results have shown that DNA bases could be identified by their characteristic tunneling signals. Measurements taken in aqueous buffered solution showed that single base resolution could be achieved with economic setups. In chapter 7, it is illustrated that some ongoing measurements are indicating the sequence readout by making linear scan on a piece of short DNA oligomer. However, to overcome the difficulties of controlling DNA especially ssDNA movement, it is much better to have the tunneling measurement incorporated onto a robust nanopore device to realize sequential reading of the DNA sequence while it is being translocated.
ContributorsHuang, Shuo (Author) / Lindsay, Stuart (Thesis advisor) / Sankey, Otto (Committee member) / Tao, Nongjian (Committee member) / Drucker, Jeff (Committee member) / Ros, Robert (Committee member) / Arizona State University (Publisher)
Created2011
149767-Thumbnail Image.png
Description
ABSTRACT Epidemiological studies have suggested a link between nut consumption and weight. The possible effects of regular nut consumption as a method of weight loss has shown minimal results with 2-3 servings of nut products per day. This 8 week study sought to investigate the effect of more modest nut

ABSTRACT Epidemiological studies have suggested a link between nut consumption and weight. The possible effects of regular nut consumption as a method of weight loss has shown minimal results with 2-3 servings of nut products per day. This 8 week study sought to investigate the effect of more modest nut consumption (1 oz./day, 5 days/week) on dietary compensation in healthy overweight individuals. Overweight and obese participants (n = 28) were recruited from the local community and were randomly assigned to either almond (NUT) or control (CON) group in this randomized, parallel-arm study. Subjects were instructed to eat their respective foods 30 minutes before the dinner meal. 24 hour diet recalls were completed pre-trial and at study weeks 1, 4 and 8. Self-reported satiety data were completed at study weeks 1, 4, and 8. Attrition was unexpectedly high, with 13 participants completing 24 dietary recall data through study week 8. High attrition limited statistical analyses. Results suggested a lack of effect for time or interaction for satiety data (within groups p = 0.997, between groups p = 0.367). Homogeneity of of inter-correlations could not be tested for 24-hour recall data as there were fewer than 2 nonsingular cell covariance matrices. In conclusion, this study was unable to prove or disprove the effectiveness of almonds to induce dietary compensation.
ContributorsJahns, Marshall (Author) / Johnston, Carol (Thesis advisor) / Hall, Richard (Committee member) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Arizona State University (Publisher)
Created2011
150364-Thumbnail Image.png
Description
Dual-wavelength laser sources have various existing and potential applications in wavelength division multiplexing, differential techniques in spectroscopy for chemical sensing, multiple-wavelength interferometry, terahertz-wave generation, microelectromechanical systems, and microfluidic lab-on-chip systems. In the drive for ever smaller and increasingly mobile electronic devices, dual-wavelength coherent light output from a single semiconductor laser

Dual-wavelength laser sources have various existing and potential applications in wavelength division multiplexing, differential techniques in spectroscopy for chemical sensing, multiple-wavelength interferometry, terahertz-wave generation, microelectromechanical systems, and microfluidic lab-on-chip systems. In the drive for ever smaller and increasingly mobile electronic devices, dual-wavelength coherent light output from a single semiconductor laser diode would enable further advances and deployment of these technologies. The output of conventional laser diodes is however limited to a single wavelength band with a few subsequent lasing modes depending on the device design. This thesis investigates a novel semiconductor laser device design with a single cavity waveguide capable of dual-wavelength laser output with large spectral separation. The novel dual-wavelength semiconductor laser diode uses two shorter- and longer-wavelength active regions that have separate electron and hole quasi-Fermi energy levels and carrier distributions. The shorter-wavelength active region is based on electrical injection as in conventional laser diodes, and the longer-wavelength active region is then pumped optically by the internal optical field of the shorter-wavelength laser mode, resulting in stable dual-wavelength laser emission at two different wavelengths quite far apart. Different designs of the device are studied using a theoretical model developed in this work to describe the internal optical pumping scheme. The carrier transport and separation of the quasi-Fermi distributions are then modeled using a software package that solves Poisson's equation and the continuity equations to simulate semiconductor devices. Three different designs are grown using molecular beam epitaxy, and broad-area-contact laser diodes are processed using conventional methods. The modeling and experimental results of the first generation design indicate that the optical confinement factor of the longer-wavelength active region is a critical element in realizing dual-wavelength laser output. The modeling predicts lower laser thresholds for the second and third generation designs; however, the experimental results of the second and third generation devices confirm challenges related to the epitaxial growth of the structures in eventually demonstrating dual-wavelength laser output.
ContributorsGreen, Benjamin C (Author) / Zhang, Yong-Hang (Thesis advisor) / Ning, Cun-Zheng (Committee member) / Tao, Nongjian (Committee member) / Roedel, Ronald J (Committee member) / Arizona State University (Publisher)
Created2011
150415-Thumbnail Image.png
Description
ABSTRACT This study evaluated the LoseIt Smart Phone app by Fit Now Inc. for nutritional quality among users during an 8 week behavioral modification weight loss protocol. All participants owned smart phones and were cluster randomized to either a control group using paper and pencil record keeping, a memo grou

ABSTRACT This study evaluated the LoseIt Smart Phone app by Fit Now Inc. for nutritional quality among users during an 8 week behavioral modification weight loss protocol. All participants owned smart phones and were cluster randomized to either a control group using paper and pencil record keeping, a memo group using a memo function on their smart phones, or the LoseIt app group which was composed of the participants who owned iPhones. Thirty one participants completed the study protocol: 10 participants from the LoseIt app group, 10 participants from the memo group, and 11 participants from the paper and pencil group. Food records were analyzed using Food Processor by ESHA and the nutritional quality was scored using the Healthy Eating Index - 2005 (HEI-2005). Scores were compared using One-Way ANOVA with no significant changes in any category across all groups. Non-parametric statistics were then used to determine changes between combined memo and paper and pencil groups and the LoseIt app group as the memo and paper and pencil group received live counseling at biweekly intervals and the LoseIt group did not. No significant difference was found in HEI scores across all categories, however a trend was noted for total HEI score with higher scores among the memo and paper and pencil group participants p=0.091. Conclusion, no significant difference was detected between users of the smart phone app LoseIt and memo and paper and pencil groups. More research is needed to determine the impact of in-person counseling versus user feedback provided with the LoseIt smart phone app.
ContributorsCowan, David Kevin (Author) / Johnston, Carol (Thesis advisor) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Mayol-Kreiser, Sandra (Committee member) / Arizona State University (Publisher)
Created2011