Filtering by
- Status: Published
![166652-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2022-05/166652-thumbnail-image.png?versionId=jXNGKy3MnIFJ0r_MGbfMzsN3dFOiSnAA&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T040025Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=d38d31c3bb82afef1146439564311728b43f6ef8945e97146cb1fcbe4cd60033&itok=SihyN8rX)
With the increase in the severity of drought conditions in the Southwest region of the U.S. paired with rising temperatures, it is becoming increasingly important to look at the systems used to keep people cool in hot-arid cities like Tempe, Arizona. Outdoor misting systems are often deployed by businesses. These systems rely on the evaporative cooling effect of water. This study examines the relationship between misting droplet size, water usage, and thermal comfort using low-pressure misting systems, tested within hot and dry conditions representative of the arid U.S. southwest. A model misting system using three nozzle orifice sizes was set up in a controlled heat chamber environment (starting baseline conditions of 40°C air temperature and 15 % relative humidity). Droplet size was measured using water-reactive paper, while water use was determined based on weight-change measurements. These measurements were paired with temperature and humidity measurements observed in several locations around the chamber to allow for a spatial analysis. Thermal comfort is determined based on psychrometric changes (temperature and absolute humidity) within the room. On average, air temperatures decreased between 2 to 4°C depending on nozzle size and sensor location. The 0.4 mm nozzle had a decent spread across the heat chamber and balanced water usage and effectiveness well. Limitations within the study showed ventilation is important for an effective system, corroborating other studies findings and suggesting that adding air circulation could improve evaporation and comfort and thus effectiveness. Finally, visual cues, such as wetted surfaces, can signal businesses to change nozzle sizes and/or make additional modifications to the system area.
![193043-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2024-04/193043-Thumbnail%20Image.png?versionId=DB4jQW.8kN0hXBVeJpT_HTELdk8k8uhN&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240615/us-west-2/s3/aws4_request&X-Amz-Date=20240615T171055Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=2c2c3477ca9ca697ed33cc60804ce40891231a257de1cdb2f0538d31d815320a&itok=LvM1EWk1)
![156599-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/156599-Thumbnail%20Image.png?versionId=ZSobBAMMU5DiYx3_GX8_5FcD5j0Ie4id&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240615/us-west-2/s3/aws4_request&X-Amz-Date=20240615T233424Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=7c696a21a6ada0b482809db4944528da472d6a6251b785c317d13b5c972ab84c&itok=BdYXN4-l)
![157548-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/157548-Thumbnail%20Image.png?versionId=22bH4Zs6pfsEiH49m1TczldW9RQjfBdA&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240614/us-west-2/s3/aws4_request&X-Amz-Date=20240614T231758Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=377df7249aecc341069565ef446a75626d266693a8e8ef983e3c3c51c5a07f36&itok=2qzzqvfD)
The first paper is based on a systematic literature review where evidence from morphological mitigation strategies in HUDs were critically reviewed, synthesized and integrated. Metrics, measurements, and methods were extracted to examine the applicability of the different strategies, and a content synthesis identified the levels of strategy success. Collective challenges and uncertainties were interpreted to compare aspirational goals from actualities of morphological mitigation strategies.
The second paper unpacks the relationship of urban morphological attributes in influencing thermal conditions to assess latent magnitudes of heat amelioration strategies. Mindful of the challenges presented in the first study, a 92-day summer field-measurement campaign captured system dynamics of urban thermal stimuli within sub-diurnal phenomena. A composite data set of sub-hourly air temperature measurements with sub-meter morphological attributes was built, statistically analyzed, and modeled. Morphological mediation effects were found to vary hourly with different patterns under varying weather conditions in non-linear associations. Results suggest mitigation interventions be investigated and later tested on a site- use and time-use basis.
The third paper concludes with a simulation-based study to conform on the collective findings of the earlier studies. The microclimate model ENVI-met 4.4, combined with field measurements, was used to simulate the effect of rooftop shade-sails in cooling the near ground thermal environment. Results showed significant cooling effects and thus presented a novel shading approach that challenges orthodox mitigation strategies in HUDs.
![154644-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/154644-Thumbnail%20Image.png?versionId=2ipyD.PNPb2gaOnnnr_P.MupZbE.qYry&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240615/us-west-2/s3/aws4_request&X-Amz-Date=20240615T150151Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=1f970661a38d4721b755a6516569c1cf8815ccebd91d9d7fde0d8b4cac41e5f8&itok=LdYRkjiV)
During summer 2015, a study was conducted to characterize effects of tree species and shade structures on outdoor human thermal comfort under hot, arid conditions. Motivating the research was the hypothesis that tree species and shade structures will vary in their capacity to improve thermal comfort due to their respective abilities to attenuate solar radiation. Micrometeorological data was collected in full sun and under shade of six landscape tree species and park ramadas in Phoenix, AZ during pre-monsoon summer afternoons. The six landscape tree species included: Arizona ash (Fraxinus velutina Torr.), Mexican palo verde (Parkinsonia aculeata L.), Aleppo pine (Pinus halepensis Mill.), South American mesquite (Prosopis spp. L.), Texas live oak (Quercus virginiana for. fusiformis Mill.), and Chinese elm (Ulmus parvifolia Jacq.). Results showed that the tree species and ramadas were not similarly effective at improving thermal comfort, represented by physiologically equivalent temperature (PET). The difference between PET in full sun and under shade was greater under Fraxinus and Quercus than under Parkinsonia, Prosopis, and ramadas by 2.9-4.3 °C. Radiation was a significant driver of PET (p<0.0001, R2=0.69) and with the exception of ramadas, lower radiation corresponded with lower PET. Variations observed in this study suggest selecting trees or structures that attenuate the most solar radiation is a potential strategy for optimizing PET.
![156385-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/156385-Thumbnail%20Image.png?versionId=iuat6r4oPpyni6tXJ8QIzCKAeYXU9Uyt&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240616/us-west-2/s3/aws4_request&X-Amz-Date=20240616T071919Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=21de38b0c379e6902495e0493586c8fc8aa1025559d91048ce708af8be471f8a&itok=OKztxGvh)
![158350-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/158350-Thumbnail%20Image.png?versionId=9yi23O64uPyW4ajZSO73qbgQz.sRdAvN&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240615/us-west-2/s3/aws4_request&X-Amz-Date=20240615T080616Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=a5ef9833ece34f793642824114c8473c348ab3271174aec57384675c087c5298&itok=HEFDbiYR)
The results suggest that social stability depends on a society’s ability to integrate change and promote interdependency. In part, this ability is constrained or promoted by social structure and the different, relationship dependencies among individuals that lead to a particular social structure. Four elements are important to constraining or promoting social stability—structural cohesion, transitivity and social dependency, geographic isolation, and types of exchange. Through the framework provided in this research, an archaeologist can recognize patterns in the archaeological data that reflect and promote social stability, or lead to collapse.
Results based on comparisons between the social networks of the Northern and Southern regions of the Valencian Bronze Age show that the Southern Region’s social structure was less stable through time. The Southern Region’s social structure consisted of competing cores of exchange. This type of competition often leads to power imbalances, conflict, and instability. Strong dependencies on the neighboring Argaric during the Early and Middle Bronze Ages and contributed to the Southern Region’s inability to maintain social stability after the Argaric collapsed. Furthermore, the Southern Region participated in the exchange of more complex technology—bronze. Complex technologies produce networks with hub and spoke structures highly vulnerable to collapse after the destruction of a hub. The Northern Region’s social structure remained structurally cohesive through time, promoting social stability.
![158797-Thumbnail Image.png](https://d1rbsgppyrdqq4.cloudfront.net/s3fs-public/styles/width_400/public/2021-09/158797-Thumbnail%20Image.png?versionId=3n.6e3cSviUsSnrHtWbWb8jGI2wYe2ad&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Credential=AKIASBVQ3ZQ42ZLA5CUJ/20240615/us-west-2/s3/aws4_request&X-Amz-Date=20240615T085633Z&X-Amz-SignedHeaders=host&X-Amz-Expires=120&X-Amz-Signature=fd1d0355481cf53a499eb2bee900436bc72927d81f70c4106d42ab324295b6f5&itok=wqUg3eBU)
Urban climate conditions are the physical manifestation of formal and informal social forces of design, policy, and urban management. The urban design community (e.g. planners, architects, urban designers, landscape architects, engineers) impacts urban development through influential built projects and design discourse. Their decisions create urban landscapes that impact physiological and mental health for people that live in and around them. Therefore, to understand possible opportunities for decision-making to support healthier urban environments and communities, this dissertation examines the role of neighborhood design on the thermal environment and the effect the thermal environment has on mental health. In situ data collection and numerical modeling are used to assess current and proposed urban design configurations in the Edison Eastlake public housing community in central Phoenix for their efficacy in cooling the thermal environment. A distributed lagged non-linear model is used to investigate the relative risk of hospitalization for schizophrenia in Maricopa County based on atmospheric conditions. The dissertation incorporates both an assessment of design strategies for the cooling of the thermal environment and an analysis of the existing thermal environment’s relationship with mental health. By reframing the urban design of neighborhoods through the lens of urban climate, this research reinforces the importance of incorporating the community into the planning process and highlights some unintended outcomes of prioritizing the thermal environment in urban design.