Matching Items (106)
150036-Thumbnail Image.png
Description
Demand for biosensor research applications is growing steadily. According to a new report by Frost & Sullivan, the biosensor market is expected to reach $14.42 billion by 2016. Clinical diagnostic applications continue to be the largest market for biosensors, and this demand is likely to continue through 2016 and beyond.

Demand for biosensor research applications is growing steadily. According to a new report by Frost & Sullivan, the biosensor market is expected to reach $14.42 billion by 2016. Clinical diagnostic applications continue to be the largest market for biosensors, and this demand is likely to continue through 2016 and beyond. Biosensor technology for use in clinical diagnostics, however, requires translational research that moves bench science and theoretical knowledge toward marketable products. Despite the high volume of academic research to date, only a handful of biomedical devices have become viable commercial applications. Academic research must increase its focus on practical uses for biosensors. This dissertation is an example of this increased focus, and discusses work to advance microfluidic-based protein biosensor technologies for practical use in clinical diagnostics. Four areas of work are discussed: The first involved work to develop reusable/reconfigurable biosensors that are useful in applications like biochemical science and analytical chemistry that require detailed sensor calibration. This work resulted in a prototype sensor and an in-situ electrochemical surface regeneration technique that can be used to produce microfluidic-based reusable biosensors. The second area of work looked at non-specific adsorption (NSA) of biomolecules, which is a persistent challenge in conventional microfluidic biosensors. The results of this work produced design methods that reduce the NSA. The third area of work involved a novel microfluidic sensing platform that was designed to detect target biomarkers using competitive protein adsorption. This technique uses physical adsorption of proteins to a surface rather than complex and time-consuming immobilization procedures. This method enabled us to selectively detect a thyroid cancer biomarker, thyroglobulin, in a controlled-proteins cocktail and a cardiovascular biomarker, fibrinogen, in undiluted human serum. The fourth area of work involved expanding the technique to produce a unique protein identification method; Pattern-recognition. A sample mixture of proteins generates a distinctive composite pattern upon interaction with a sensing platform consisting of multiple surfaces whereby each surface consists of a distinct type of protein pre-adsorbed on the surface. The utility of the "pattern-recognition" sensing mechanism was then verified via recognition of a particular biomarker, C-reactive protein, in the cocktail sample mixture.
ContributorsChoi, Seokheun (Author) / Chae, Junseok (Thesis advisor) / Tao, Nongjian (Committee member) / Yu, Hongyu (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
150048-Thumbnail Image.png
Description
A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene,

A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene, and xylenes (BTEX) via a homemade molecular imprinted polymer, and a specific detection and control circuit. The device is a wireless, portable, battery-powered, and cell-phone operated device. The device has been calibrated and validated in the laboratory and using selected ion flow tube mass spectrometry (SFIT-MS). The capability and robustness are also demonstrated in some field tests. It provides rapid and reliable detection of BTEX in real samples, including challenging high concentrations of interferents, and it is suitable for occupational, environmental health and epidemiological applications.
ContributorsChen, Zheng (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
149990-Thumbnail Image.png
Description
The effects of a long-term combat deployment on a soldier's physical fitness are not well understood. In active duty soldiers, combat deployment reduced physical fitness compared to pre-deployment status, but no similar research has been performed on Army National Guard soldiers. This study is the first to identify physical fitness

The effects of a long-term combat deployment on a soldier's physical fitness are not well understood. In active duty soldiers, combat deployment reduced physical fitness compared to pre-deployment status, but no similar research has been performed on Army National Guard soldiers. This study is the first to identify physical fitness changes in Arizona National Guard (AZNG) soldiers following deployment to a combat zone and to assess the relationships between physical fitness and non-combat injuries and illness (NCII). Sixty soldiers from the Arizona National Guard (AZNG) completed a battery of physical fitness tests prior to deployment and within 1-7 days of returning from a 12-month deployment to Iraq. Pre and post-deployment measures assessed body composition (Bod Pod), muscular strength (1RM bench press, back-squat), muscular endurance (push-up, sit-up), power (Wingate cycle test), cardiorespiratory fitness (treadmill run to VO2 peak), and flexibility (sit-and-reach, trunk extension, shoulder elevation). Post deployment, medical records were reviewed by a blinded researcher and inventoried for NCII that occurred during deployment. Data were analyzed for changes between pre and post-deployment physical fitness. Relationships between fitness and utilization of medical resources for NCII were then determined. Significant declines were noted in mean cardiorespiratory fitness (-10.8%) and trunk flexibility (-6.7%). Significant improvements were seen in mean level of fat mass (-11.1%), relative strength (bench press, 10.2%, back-squat 14.2%) and muscular endurance (push-up 16.4%, sit-up 11.0%). Significant (p < 0.05) negative correlations were detected between percentage change in fat mass and gastrointestinal visits (r = -0.37); sit-and-reach and lower extremity visits (r= -0.33); shoulder elevation and upper extremity visits (r= -0.36); and cardiorespiratory fitness and back visits (r= -0.31); as well as behavioral health visits (r= -0.28). Cardiorespiratory fitness changes were grouped into tertiles. Those who lost the greatest fitness had significantly greater number of NCII visits (8.0 v 3.1 v 2.6, p = .03). These data indicate a relationship between the decline in cardiorespiratory fitness and an overall increase in utilization of medical resources. The results may provide incentive to military leaders to ensure that soldiers maintain their cardiorespiratory fitness throughout the extent of their deployment.
ContributorsWarr, Bradley (Author) / Swan, Pamela (Thesis advisor) / Lee, Chong (Committee member) / Campbell, Kathryn (Committee member) / Erickson, Steven (Committee member) / Alvar, Brent (Committee member) / Arizona State University (Publisher)
Created2011
149647-Thumbnail Image.png
Description
This thesis describes several approaches to next generation DNA sequencing via tunneling current method based on a Scanning Tunneling Microscope system. In chapters 5 and 6, preliminary results have shown that DNA bases could be identified by their characteristic tunneling signals. Measurements taken in aqueous buffered solution showed that single

This thesis describes several approaches to next generation DNA sequencing via tunneling current method based on a Scanning Tunneling Microscope system. In chapters 5 and 6, preliminary results have shown that DNA bases could be identified by their characteristic tunneling signals. Measurements taken in aqueous buffered solution showed that single base resolution could be achieved with economic setups. In chapter 7, it is illustrated that some ongoing measurements are indicating the sequence readout by making linear scan on a piece of short DNA oligomer. However, to overcome the difficulties of controlling DNA especially ssDNA movement, it is much better to have the tunneling measurement incorporated onto a robust nanopore device to realize sequential reading of the DNA sequence while it is being translocated.
ContributorsHuang, Shuo (Author) / Lindsay, Stuart (Thesis advisor) / Sankey, Otto (Committee member) / Tao, Nongjian (Committee member) / Drucker, Jeff (Committee member) / Ros, Robert (Committee member) / Arizona State University (Publisher)
Created2011
149787-Thumbnail Image.png
Description
High Intensity Interval Training (HIIT) is a phrase quickly becoming popularized through current research due to the physical and physiological success this method of training has proven to yield in both untrained and trained individuals. There is no set definition used to describe HIIT, but it typically refers to repeated

High Intensity Interval Training (HIIT) is a phrase quickly becoming popularized through current research due to the physical and physiological success this method of training has proven to yield in both untrained and trained individuals. There is no set definition used to describe HIIT, but it typically refers to repeated bouts of fairly brief intermittent exercise. A great deal of research outlines the benefits associated with utilizing HIIT in untrained and recreationally trained individuals. However, research on the effect HIIT has or could possibly have on the well-trained endurance athlete is limited, specifically in the sport of rowing. The purpose of this study was to analyze the effect of HIIT on VO2 peak and performance in trained rowers when compared to traditional, endurance training. It was hypothesized that HIIT would be just as effective at improving VO2 peak and performance as the endurance training protocol in well-trained rowers. A total of 20 high school female rowers participated in the study (mean ± SD; age = 16 ± 1). Baseline testing was comprised of a 2000m time-trial test on the Concept IIc Rowing Ergometer and a maximal exercise test, which was also completed on the Concept IIc Ergometer, in order to determine VO2 peak. Subjects were randomly assigned to a HIIT or endurance group for four weeks of intervention. Three days/week the HIIT group completed a 6 by 30second repeated Wingate protocol on the Concept II Ergometer at or above 100% VO2 peak, in which each 30s maximal effort was immediately followed by an active recovery of four-minutes. The endurance group completed 30 minutes of sub-maximal rowing at 65% of VO2 peak three days/week. After four weeks of intervention, post-testing took place, which was identical to baseline testing. Results from this study suggest HIIT was just as effective as endurance training at improving 2k time (mean ± SD; HIIT: 498.7 ± 23.1; Endurance: 497.5 ± 17.6). There were no significant within or between group differences in VO2 peak post-intervention (mean ± SD; HIIT: 44.8 ± 4.0; Endurance: 45.8 ± 5.6). The current study suggests four-weeks of HIIT training can yield similar adaptations in performance when compared to endurance training.
ContributorsCarr, Natasha (Author) / Chisum, Jack (Thesis advisor) / Campbell, Kathryn (Committee member) / Woodruff, Larry (Committee member) / Arizona State University (Publisher)
Created2011
150364-Thumbnail Image.png
Description
Dual-wavelength laser sources have various existing and potential applications in wavelength division multiplexing, differential techniques in spectroscopy for chemical sensing, multiple-wavelength interferometry, terahertz-wave generation, microelectromechanical systems, and microfluidic lab-on-chip systems. In the drive for ever smaller and increasingly mobile electronic devices, dual-wavelength coherent light output from a single semiconductor laser

Dual-wavelength laser sources have various existing and potential applications in wavelength division multiplexing, differential techniques in spectroscopy for chemical sensing, multiple-wavelength interferometry, terahertz-wave generation, microelectromechanical systems, and microfluidic lab-on-chip systems. In the drive for ever smaller and increasingly mobile electronic devices, dual-wavelength coherent light output from a single semiconductor laser diode would enable further advances and deployment of these technologies. The output of conventional laser diodes is however limited to a single wavelength band with a few subsequent lasing modes depending on the device design. This thesis investigates a novel semiconductor laser device design with a single cavity waveguide capable of dual-wavelength laser output with large spectral separation. The novel dual-wavelength semiconductor laser diode uses two shorter- and longer-wavelength active regions that have separate electron and hole quasi-Fermi energy levels and carrier distributions. The shorter-wavelength active region is based on electrical injection as in conventional laser diodes, and the longer-wavelength active region is then pumped optically by the internal optical field of the shorter-wavelength laser mode, resulting in stable dual-wavelength laser emission at two different wavelengths quite far apart. Different designs of the device are studied using a theoretical model developed in this work to describe the internal optical pumping scheme. The carrier transport and separation of the quasi-Fermi distributions are then modeled using a software package that solves Poisson's equation and the continuity equations to simulate semiconductor devices. Three different designs are grown using molecular beam epitaxy, and broad-area-contact laser diodes are processed using conventional methods. The modeling and experimental results of the first generation design indicate that the optical confinement factor of the longer-wavelength active region is a critical element in realizing dual-wavelength laser output. The modeling predicts lower laser thresholds for the second and third generation designs; however, the experimental results of the second and third generation devices confirm challenges related to the epitaxial growth of the structures in eventually demonstrating dual-wavelength laser output.
ContributorsGreen, Benjamin C (Author) / Zhang, Yong-Hang (Thesis advisor) / Ning, Cun-Zheng (Committee member) / Tao, Nongjian (Committee member) / Roedel, Ronald J (Committee member) / Arizona State University (Publisher)
Created2011
149850-Thumbnail Image.png
Description
ABSTRACT The purpose of this study was to determine the energy cost of four modes of resistance training (push-ups, pull-ups, curl-ups, lunges). Twelve well trained men aged 23.6 (SD=2.84) years were recruited to participate in the study. Each of the 12 men completed three trials of each of

ABSTRACT The purpose of this study was to determine the energy cost of four modes of resistance training (push-ups, pull-ups, curl-ups, lunges). Twelve well trained men aged 23.6 (SD=2.84) years were recruited to participate in the study. Each of the 12 men completed three trials of each of the four exercises on one visit to the laboratory lasting slightly over one hour (M=72 min, SD=5.9 min). The oxygen consumption of the men was monitored constantly throughout the trial and data was recorded every five seconds. Mean VO2 values were calculated for each exercise. The values for push-ups (M=11.57 ml/kg/min, SD=1.99), curl-ups (M=10.99 ml/kg/min, SD=1.48), pull-ups (M=10.87 ml/kg/min, SD=2.51), and lunges (M=14.18 ml/kg/min, SD=1.78) were converted to METs (Metabolic Equivalents). The MET values (3.31, 3.14, 3.11, and 4.05 respectively) all fall within the range of moderate intensity activity. The findings of this study show that a single set of any of the above exercises will qualify as a moderate intensity activity and can be used to meet recommendations on daily physical activity.
ContributorsVezina, Jesse (Author) / Ainsworth, Barbara (Thesis advisor) / Campbell, Kathryn (Committee member) / Woodruff, Larry (Committee member) / Arizona State University (Publisher)
Created2011
150245-Thumbnail Image.png
Description
Nanofluidic devices in which one single-walled carbon nanotube (SWCNT) spans a barrier between two fluid reservoirs were constructed, enabling direct electrical measurement of the transport of ions and molecules. Ion current through these devices is about 2 orders of magnitude larger than that predicted from the bulk resistivity of the

Nanofluidic devices in which one single-walled carbon nanotube (SWCNT) spans a barrier between two fluid reservoirs were constructed, enabling direct electrical measurement of the transport of ions and molecules. Ion current through these devices is about 2 orders of magnitude larger than that predicted from the bulk resistivity of the electrolyte. Electroosmosis drives excess current, carried by cations, and is found to be the origin of giant ionic current through SWCNT as shown by building an ionic field-effect transistor with a gate electrode embedded in the fluid barrier. Wetting of inside of the semi-conducting SWCNT by water showed the change of its electronic property, turning the electronic SWCNT field-effect transistor to "on" state. These findings provide a new method to investigate and control the ion and molecule behavior at nanoscale.
ContributorsPang, Pei (Author) / Lindsay, Stuart (Thesis advisor) / Ros, Robert (Committee member) / Shumway, John (Committee member) / Tao, Nongjian (Committee member) / Menéndez, Jose (Committee member) / Arizona State University (Publisher)
Created2011
150198-Thumbnail Image.png
Description
In this project, a novel method is presented for measuring the resistivity of nanoscale metallic conductors (nanowires) using a variable-spacing 2-point method with a modified ultrahigh vacuum scanning tunneling microscope. An auxiliary field emission imaging method that allows for scanning insulating surfaces using a large gap distance (20nm) is also

In this project, a novel method is presented for measuring the resistivity of nanoscale metallic conductors (nanowires) using a variable-spacing 2-point method with a modified ultrahigh vacuum scanning tunneling microscope. An auxiliary field emission imaging method that allows for scanning insulating surfaces using a large gap distance (20nm) is also presented. Using these methods, the resistivity of self-assembled endotaxial FeSi2 nanowires (NWs) on Si(110) was measured. The resistivity was found to vary inversely with NW width, being rhoNW = 200 uOhm cm at 12 nm and 300 uOhm cm at 2 nm. The increase at small w is attributed to boundary scattering, and is fit to the Fuchs-Sondheimer model, yielding values of rho0 = 150 uOhm cm and lambda = 2.4 nm, for specularity parameter p = 0.5. These results are attributed to a high concentration of point defects in the FeSi2 structure, with a correspondingly short inelastic electron scattering length. It is remarkable that the defect concentration persists in very small structures, and is not changed by surface oxidation.
ContributorsTobler, Samuel (Author) / Bennett, Peter (Thesis advisor) / McCartney, Martha (Committee member) / Tao, Nongjian (Committee member) / Doak, Bruce (Committee member) / Chen, Tingyong (Committee member) / Arizona State University (Publisher)
Created2011
Description
Obtaining local electrochemical (EC) information is extremely important for understanding basic surface reactions, and for many applications. Scanning electrochemical microscopy (SECM) can obtain local EC information by scanning a microelectrode across the surface. Although powerful, SECM is slow, the scanning microelectrode may perturb reaction and the measured signal decreases with

Obtaining local electrochemical (EC) information is extremely important for understanding basic surface reactions, and for many applications. Scanning electrochemical microscopy (SECM) can obtain local EC information by scanning a microelectrode across the surface. Although powerful, SECM is slow, the scanning microelectrode may perturb reaction and the measured signal decreases with the size of microelectrode. This thesis demonstrates a new imaging technique based on a principle that is completely different from the conventional EC detection technologies. The technique, referred to as plasmonic-based electrochemical imaging (PECI), images local EC current (both faradaic and non-faradaic) without using a scanning microelectrode. Because PECI response is an optical signal originated from surface plasmon resonance (SPR), PECI is fast and non-invasive and its signal is proportional to incident light intensity, thus does not decrease with the area of interest. A complete theory is developed in this thesis work to describe the relationship between EC current and PECI signal. EC current imaging at various fixed potentials and local cyclic voltammetry methods are developed and demonstrated with real samples. Fast imaging rate (up to 100,000 frames per second) with 0.2×3µm spatial resolution and 0.3 pA detection limit have been achieved. Several PECI applications have been developed to demonstrate the unique strengths of the new imaging technology. For example, trace particles in fingerprint is detected by PECI, a capability that cannot be achieved with the conventional EC technologies. Another example is PECI imaging of EC reaction and interfacial impedance of graphene of different thicknesses. In addition, local square wave voltammetry capability is demonstrated and applied to study local catalytic current of platinum nanoparticle microarray. This thesis also describes a related but different research project that develops a new method to measure surface charge densities of SPR sensor chips, and micro- and nano-particles. A third project of this thesis is to develop a method to expand the conventional SPR detection and imaging technology by including a waveguide mode. This innovation creates a sensitive detection of bulk index of refraction, which overcomes the limitation that the conventional SPR can probe only changes near the sensor surface within ~200 nm.
ContributorsShan, Xiaonan (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Christen, Jennifer Blain (Committee member) / Hayes, Mark (Committee member) / Arizona State University (Publisher)
Created2011