150722-Thumbnail Image.png
Description
In 2022, integrated circuit interconnects will approach 10 nm and the diffusion barrier layers needed to ensure long lasting devices will be at 1 nm. This dimension means the interconnect will be dominated by the interface and it has been shown the interface is currently eroding device performance. The standard

In 2022, integrated circuit interconnects will approach 10 nm and the diffusion barrier layers needed to ensure long lasting devices will be at 1 nm. This dimension means the interconnect will be dominated by the interface and it has been shown the interface is currently eroding device performance. The standard interconnect system has three layers - a Copper metal core, a Tantalum Adhesion layer and a Tantalum Nitride Diffusion Barrier Layer. An alternate interconnect schema is a Tantalum Nitride barrier layer and Silver as a metal. The adhesion layer is removed from the system along with changing to an alternate, low resistivity metal. First principles are used to assess the interface of the Silver and Tantalum Nitride. Several stoichiometric 1:1 Tantalum Nitride polymorphs are assessed and it is found that the Fe2P crystal structure is actually the most stable crystal structure which is at odds with the published phase diagram for ambient crystal structure. The surface stability of Fe2P-TaN is assessed and the absorption enthalpy of Silver adatoms is calculated. Finally, the thermodynamic stability of the TaN-Ag interconnect system is assessed.
ContributorsGrumski, Michael (Author) / Adams, James (Thesis advisor) / Krause, Stephen (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2012
151249-Thumbnail Image.png
Description
As world energy demands increase, research into more efficient energy production methods has become imperative. Heterogeneous catalysis and nanoscience are used to promote chemical transformations important for energy production. These concepts are important in solid oxide fuel cells (SOFCs) which have attracted attention because of their potential to provide an

As world energy demands increase, research into more efficient energy production methods has become imperative. Heterogeneous catalysis and nanoscience are used to promote chemical transformations important for energy production. These concepts are important in solid oxide fuel cells (SOFCs) which have attracted attention because of their potential to provide an efficient and environmentally favorable power generation system. The SOFC is also fuel-flexible with the ability to run directly on many fuels other than hydrogen. Internal fuel reforming directly in the anode of the SOFC would greatly reduce the cost and complexity of the device. Methane is the simplest hydrocarbon and a main component in natural gas, making it useful when testing catalysts on the laboratory scale. Nickel (Ni) and gadolinium (Gd) doped ceria (CeO2) catalysts for potential use in the SOFC anode were synthesized with a spray drying method and tested for catalytic performance using partial oxidation of methane and steam reforming. The relationships between catalytic performance and structure were then investigated using X-ray diffraction, transmission electron microscopy, and environmental transmission electron microscopy. The possibility of solid solutions, segregated phases, and surface layers of Ni were explored. Results for a 10 at.% Ni in CeO2 catalyst reveal a poor catalytic behavior while a 20 at.% Ni in CeO2 catalyst is shown to have superior activity. The inclusion of both 10 at.% Gd and 10 at.% Ni in CeO2 enhances the catalytic performance. Analysis of the presence of Ni in all 3 samples reveals Ni heterogeneity and little evidence for extensive solid solution doping. Ni is found in small domains throughout CeO2 particles. In the 20 at.% Ni sample a segregated, catalytically active NiO phase is observed. Overall, it is found that significant interaction between Ni and CeO2 occurs that could affect the synthesis and functionality of the SOFC anode.
ContributorsCavendish, Rio (Author) / Crozier, Peter (Thesis advisor) / Adams, James (Committee member) / Smith, David (Committee member) / Arizona State University (Publisher)
Created2012
151170-Thumbnail Image.png
Description
Cancer claims hundreds of thousands of lives every year in US alone. Finding ways for early detection of cancer onset is crucial for better management and treatment of cancer. Thus, biomarkers especially protein biomarkers, being the functional units which reflect dynamic physiological changes, need to be discovered. Though important, there

Cancer claims hundreds of thousands of lives every year in US alone. Finding ways for early detection of cancer onset is crucial for better management and treatment of cancer. Thus, biomarkers especially protein biomarkers, being the functional units which reflect dynamic physiological changes, need to be discovered. Though important, there are only a few approved protein cancer biomarkers till date. To accelerate this process, fast, comprehensive and affordable assays are required which can be applied to large population studies. For this, these assays should be able to comprehensively characterize and explore the molecular diversity of nominally "single" proteins across populations. This information is usually unavailable with commonly used immunoassays such as ELISA (enzyme linked immunosorbent assay) which either ignore protein microheterogeneity, or are confounded by it. To this end, mass spectrometric immuno assays (MSIA) for three different human plasma proteins have been developed. These proteins viz. IGF-1, hemopexin and tetranectin have been found in reported literature to show correlations with many diseases along with several carcinomas. Developed assays were used to extract entire proteins from plasma samples and subsequently analyzed on mass spectrometric platforms. Matrix assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) mass spectrometric techniques where used due to their availability and suitability for the analysis. This resulted in visibility of different structural forms of these proteins showing their structural micro-heterogeneity which is invisible to commonly used immunoassays. These assays are fast, comprehensive and can be applied in large sample studies to analyze proteins for biomarker discovery.
ContributorsRai, Samita (Author) / Nelson, Randall (Thesis advisor) / Hayes, Mark (Thesis advisor) / Borges, Chad (Committee member) / Ros, Alexandra (Committee member) / Arizona State University (Publisher)
Created2012
151271-Thumbnail Image.png
Description
Humans moving in the environment must frequently change walking speed and direction to negotiate obstacles and maintain balance. Maneuverability and stability requirements account for a significant part of daily life. While constant-average-velocity (CAV) human locomotion in walking and running has been studied extensively unsteady locomotion has received far less attention.

Humans moving in the environment must frequently change walking speed and direction to negotiate obstacles and maintain balance. Maneuverability and stability requirements account for a significant part of daily life. While constant-average-velocity (CAV) human locomotion in walking and running has been studied extensively unsteady locomotion has received far less attention. Although some studies have described the biomechanics and neurophysiology of maneuvers, the underlying mechanisms that humans employ to control unsteady running are still not clear. My dissertation research investigated some of the biomechanical and behavioral strategies used for stable unsteady locomotion. First, I studied the behavioral level control of human sagittal plane running. I tested whether humans could control running using strategies consistent with simple and independent control laws that have been successfully used to control monopod robots. I found that humans use strategies that are consistent with the distributed feedback control strategies used by bouncing robots. Humans changed leg force rather than stance duration to control center of mass (COM) height. Humans adjusted foot placement relative to a "neutral point" to change running speed increment between consecutive flight phases, i.e. a "pogo-stick" rather than a "unicycle" strategy was adopted to change running speed. Body pitch angle was correlated by hip moments if a proportional-derivative relationship with time lags corresponding to pre-programmed reaction (87 ± 19 ms) was assumed. To better understand the mechanisms of performing successful maneuvers, I studied the functions of joints in the lower extremities to control COM speed and height. I found that during stance, the hip functioned as a power generator to change speed. The ankle switched between roles as a damper and torsional spring to contributing both to speed and elevation changes. The knee facilitated both speed and elevation control by absorbing mechanical energy, although its contribution was less than hip or ankle. Finally, I studied human turning in the horizontal plane. I used a morphological perturbation (increased body rotational inertia) to elicit compensational strategies used to control sidestep cutting turns. Humans use changes to initial body angular speed and body pre-rotation to prevent changes in braking forces.
ContributorsQiao, Mu, 1981- (Author) / Jindrich, Devin L (Thesis advisor) / Dounskaia, Natalia (Committee member) / Abbas, James (Committee member) / Hinrichs, Richard (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2012
151088-Thumbnail Image.png
Description
Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with

Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with improved ankle kinematics and kinetics. The ankle allows a person to walk normally and up and down stairs, but volitional control is still an issue. This research tackled the problem of giving the user more control over the prosthetic ankle using a force/torque circuit. When the user presses against a force/torque sensor located inside the socket the prosthetic foot plantar flexes or moves downward. This will help the user add additional push-off force when walking up slopes or stairs. It also gives the user a sense of control over the device.
ContributorsFronczyk, Adam (Author) / Sugar, Thomas G. (Thesis advisor) / Helms-Tillery, Stephen (Thesis advisor) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2012
136546-Thumbnail Image.png
Description
The generation of walking motion is one of the most vital functions of the human body because it allows us to be mobile in our environment. Unfortunately, numerous individuals suffer from gait impairment as a result of debilitating conditions like stroke, resulting in a serious loss of mobility. Our understanding

The generation of walking motion is one of the most vital functions of the human body because it allows us to be mobile in our environment. Unfortunately, numerous individuals suffer from gait impairment as a result of debilitating conditions like stroke, resulting in a serious loss of mobility. Our understanding of human gait is limited by the amount of research we conduct in relation to human walking mechanisms and their characteristics. In order to better understand these characteristics and the systems involved in the generation of human gait, it is necessary to increase the depth and range of research pertaining to walking motion. Specifically, there has been a lack of investigation into a particular area of human gait research that could potentially yield interesting conclusions about gait rehabilitation, which is the effect of surface stiffness on human gait. In order to investigate this idea, a number of studies have been conducted using experimental devices that focus on changing surface stiffness; however, these systems lack certain functionality that would be useful in an experimental scenario. To solve this problem and to investigate the effect of surface stiffness further, a system has been developed called the Variable Stiffness Treadmill system (VST). This treadmill system is a unique investigative tool that allows for the active control of surface stiffness. What is novel about this system is its ability to change the stiffness of the surface quickly, accurately, during the gait cycle, and throughout a large range of possible stiffness values. This type of functionality in an experimental system has never been implemented and constitutes a tremendous opportunity for valuable gait research in regard to the influence of surface stiffness. In this work, the design, development, and implementation of the Variable Stiffness Treadmill system is presented and discussed along with preliminary experimentation. The results from characterization testing demonstrate highly accurate stiffness control and excellent response characteristics for specific configurations. Initial indications from human experimental trials in relation to quantifiable effects from surface stiffness variation using the Variable Stiffness Treadmill system are encouraging.
ContributorsBarkan, Andrew Robert (Author) / Artemiadis, Panagiotis (Thesis director) / Santello, Marco (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2015-05
136149-Thumbnail Image.png
Description
The transition to lead-free solder in the electronics industry has benefitted the environment in many ways. However, with new materials systems comes new materials issues. During the processing of copper pads, a protective surface treatment is needed to prevent the copper from oxidizing. Characterizing the copper oxidation underneath the surface

The transition to lead-free solder in the electronics industry has benefitted the environment in many ways. However, with new materials systems comes new materials issues. During the processing of copper pads, a protective surface treatment is needed to prevent the copper from oxidizing. Characterizing the copper oxidation underneath the surface treatment is challenging but necessary for product reliability and failure analysis. Currently, FIB-SEM, which is time-consuming and expensive, is what is used to understand and analyze the surface treatment-copper oxide(s)-copper system. This project's goals were to determine a characterization methodology that cuts both characterization time and cost in half for characterizing copper oxidation beneath a surface treatment and to determine which protective surface treatment is the best as defined by multiple criterion such as cost, sustainability, and reliability. Two protective surface treatments, organic solderability preservative (OSP) and chromium zincate, were investigated, and multiple characterization techniques were researched. Six techniques were tested, and three were deemed promising. Through our studies, it was determined that the best surface treatment was organic solderability preservative (OSP) and the ideal characterization methodology would be using FIB-SEM to calibrate a QCM model, along with using SERA to confirm the QCM model results. The methodology we propose would result in a 91% reduction in characterization cost and a 92% reduction in characterization time. Future work includes further calibration of the QCM model using more FIB/SEM data points and eventually creating a model for oxide layer thickness as a function of exposure time and processing temperature using QCM as the primary data source. In doing my Capstone project for Intel, a large electronics manufacturing company, I feel it is important to remember the effects of our tools and industry on the environment and to consider the product life cycle in terms other than monetary gain and raw material recycling. To this end I will be discussing how lead is and was used in manufacturing, how it is disposed of, and how this effects the environment including plant, animal, and insect life, as well as ground water contamination. Since the ban was enacted several years ago, I will compare how lead-free alternatives currently in use compare in environmental impact and possibly raise the question of whether we have simply traded one evil for another.
ContributorsBranch Kelly, Marion Zoe (Author) / Adams, James (Thesis director) / Krause, Stephen (Committee member) / Barrett, The Honors College (Contributor) / Materials Science and Engineering Program (Contributor)
Created2015-05
136335-Thumbnail Image.png
Description
The primary motor cortex (M1) plays a vital role in motor planning and execution, as well as in motor learning. Baseline corticospinal excitability (CSE) in M1 is known to increase as a result of motor learning, but less is understand about the modulation of CSE at the pre-execution planning stage

The primary motor cortex (M1) plays a vital role in motor planning and execution, as well as in motor learning. Baseline corticospinal excitability (CSE) in M1 is known to increase as a result of motor learning, but less is understand about the modulation of CSE at the pre-execution planning stage due to learning. This question was addressed using single pulse transcranial magnetic stimulation (TMS) to measure the modulation of both baseline and planning CSE due to learning a reach to grasp task. It was hypothesized that baseline CSE would increase and planning CSE decrease as a function of trial; an increase in baseline CSE would replicate established findings in the literature, while a decrease in planning would be a novel finding. Eight right-handed subjects were visually cued to exert a precise grip force, with the goal of producing that force accurately and consistently. Subjects effectively learned the task in the first 10 trials, but no significant trends were found in the modulation of baseline or planning CSE. The lack of significant results may be due to the very quick learning phase or the lower intensity of training as compared to past studies. The findings presented here suggest that planning and baseline CSE may be modulated along different time courses as learning occurs and point to some important considerations for future studies addressing this question.
ContributorsMoore, Dalton Dale (Author) / Santello, Marco (Thesis director) / Kleim, Jeff (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
136455-Thumbnail Image.png
Description
Although wind turbine bearings are designed to operate 18-20 years, in the recent years premature failure among these bearings has caused this life to reduce to as low as a few months to a year. One of the leading causes of premature failure called white structure flaking is a mechanism

Although wind turbine bearings are designed to operate 18-20 years, in the recent years premature failure among these bearings has caused this life to reduce to as low as a few months to a year. One of the leading causes of premature failure called white structure flaking is a mechanism that was first cited in literature decades ago but not much is understood about it even today. The cause of this mode of failure results from the initiation of white etched cracks (WECs). In this report, different failure mechanisms, especially premature failure mechanisms that were tested and analyzed are demonstrated as a pathway to understanding this phenomenon. Through the use of various tribometers, samples were tested in diverse and extreme conditions in order to study the effect of these different operational conditions on the specimen. Analysis of the tested samples allowed for a comparison of the microstructure alterations in the tested samples to the field bearings affected by WSF.
ContributorsSharma, Aman (Author) / Foy, Joseph (Thesis director) / Adams, James (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2015-05
136195-Thumbnail Image.png
Description
The intervertebral disc goes through degenerative changes with age, which leads to disc thinning, bulging, or herniation. Spinal fusion treatments are ineffective as they cause quicker degeneration of adjacent discs and fail in nearly 20% of cases, so researchers have turned to tissue-engineering biocompatible intervertebral discs for transplantation. However novel

The intervertebral disc goes through degenerative changes with age, which leads to disc thinning, bulging, or herniation. Spinal fusion treatments are ineffective as they cause quicker degeneration of adjacent discs and fail in nearly 20% of cases, so researchers have turned to tissue-engineering biocompatible intervertebral discs for transplantation. However novel and effective as this may seem, these transplanted discs still show evidence of degeneration after just 5 years. I hypothesize that these discs are degenerating due to a blockage of the cartilaginous endplates post-transplantation that is hindering nutrient transport through the intervertebral disc. In order to test this hypothesis, I developed a mathematical model of nutrient transport through the intervertebral disc in one diurnal daily loading cycle. This model was used to simulate open endplates and blocked endplates and then compare differences in nutrient concentration and nutrient transport to the center of the disc. Results from the math model simulations were then compared to in vitro experimental data collected in lab to verify the findings on a physiological level. Results showed significant differences, both in vitro and in the model, between nutrient transport in open endplates vs blocked endplates, lending support to the original hypothesis. This study only presents preliminary results, but could hold the key to preventing future disc degeneration post-transplantation.
ContributorsMunter, Bryce Taylor (Author) / Santello, Marco (Thesis director) / Caplan, Michael (Committee member) / Giers, Morgan (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)