Matching Items (462)
Filtering by

Clear all filters

Description
As computers become a more embedded aspect of daily life, the importance of communicating ideas in computing and technology to the general public has become increasingly apparent. One such growing technology is electronic voting. The feasibility of explaining electronic voting protocols was directly investigated through the generation of a presentation

As computers become a more embedded aspect of daily life, the importance of communicating ideas in computing and technology to the general public has become increasingly apparent. One such growing technology is electronic voting. The feasibility of explaining electronic voting protocols was directly investigated through the generation of a presentation based on journal articles and papers identified by the investigator. Extensive use of analogy and visual aids were used to explain various cryptographic concepts. The presentation was then given to a classroom of ASU freshmen, followed by a feedback survey. A self-evaluation on the presentation methods is conducted, and a procedure for explaining subjects in computer science is proposed based on the researcher's personal process.
ContributorsReniewicki, Peter Josef (Author) / Bazzi, Rida (Thesis director) / Childress, Nancy (Committee member) / School of Mathematical and Statistical Sciences (Contributor) / Computer Science and Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
132440-Thumbnail Image.png
Description
In this experiment an Electrodynamic Ion Ring Trap was constructed and tested. Due to the nature of Electrostatic fields, the setup required an oscillating voltage source to stably trap the particles. It was built in a safe manner, The power supply was kept in a project box to avoid incidental

In this experiment an Electrodynamic Ion Ring Trap was constructed and tested. Due to the nature of Electrostatic fields, the setup required an oscillating voltage source to stably trap the particles. It was built in a safe manner, The power supply was kept in a project box to avoid incidental contact, and was connected to a small copper wire in the shape of a ring. The maximum voltage that could be experienced via incidental contact was well within safe ranges a 0.3mA. Within minutes of its completion the trap was able to trap small Lycopodium powder spores mass of approximately 1.7*10^{-11}kg in clusters of 15-30 for long timescales. The oscillations of these spores were observed to be roughly 1.01mm at their maximum, and in an attempt to understand the dynamics of the Ion Trap, a concept called the pseudo-potential of the trap was used. This method proved fairly inaccurate, involving much estimation and using a static field estimation of 9.39*10^8 N\C and a charge estimate on the particles of ~1e, a maximum oscillation distance of 1.37m was calculated. Though the derived static field strength was not far off from the field strength required to achieve the correct oscillation distance (Percent error of 9.92%, the small discrepancy caused major calculation errors. The trap's intended purpose however was to eventually trap protein molecules for mapping via XFEL laser, and after its successful construction that goal is fairly achievable. The trap was also housed in a vacuum chamber so that it could be more effectively implemented with the XFEL.
ContributorsNicely, Ryan Joseph (Author) / Kirian, Richard (Thesis director) / Weiterstall, Uwe (Committee member) / School of Mathematical and Statistical Sciences (Contributor) / Department of Physics (Contributor) / Barrett, The Honors College (Contributor)
Created2019-05