Matching Items (460)
Filtering by

Clear all filters

128702-Thumbnail Image.png
Description

The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight,

The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays.

ContributorsLipowicz, Michelle (Author) / Garcia, Antonio (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-06-02
128709-Thumbnail Image.png
Description

Pure coconut oil, lanolin, and acetaminophen were vaporized at rates of 1–50 mg/min, using a porous network exhibiting a temperature gradient from 5000 to 5500 K/mm, without incurring noticeable chemical changes due to combustion, oxidation, or other thermally-induced chemical structural changes. The newly coined term “ereptiospiration” is used here to

Pure coconut oil, lanolin, and acetaminophen were vaporized at rates of 1–50 mg/min, using a porous network exhibiting a temperature gradient from 5000 to 5500 K/mm, without incurring noticeable chemical changes due to combustion, oxidation, or other thermally-induced chemical structural changes. The newly coined term “ereptiospiration” is used here to describe this combination of thermal transpiration at high temperature gradients since the process can force the creation of thermal aerosols by rapid heating in a localized zone. Experimental data were generated for these materials using two different supports for metering the materials to the battery powered coil: namely, a stainless steel fiber bundle and a 3-D printed steel cartridge. Heating coconut oil, lanolin, or acetaminophen in a beaker to lower temperatures than those achieved at the surface of the coil showed noticeable and rapid degradation in the samples, while visual and olfactory observations for ereptiospiration showed no noticeable degradation in lanolin and coconut oil while HPLC chromatograms along with visual observation confirm that within the limit of detection, acetaminophen remains chemically unaltered by ereptiospiration.

ContributorsWoolley, Christine (Author) / Garcia, Antonio (Author) / Santello, Marco (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2017-04-12
128720-Thumbnail Image.png
Description

The constant information radar, or CIR, is a tracking radar that modulates target revisit time by maintaining a fixed mutual information measure. For highly dynamic targets that deviate significantly from the path predicted by the tracking motion model, the CIR adjusts by illuminating the target more frequently than it would

The constant information radar, or CIR, is a tracking radar that modulates target revisit time by maintaining a fixed mutual information measure. For highly dynamic targets that deviate significantly from the path predicted by the tracking motion model, the CIR adjusts by illuminating the target more frequently than it would for well-modeled targets. If SNR is low, the radar delays revisit to the target until the state entropy overcomes noise uncertainty. As a result, we show that the information measure is highly dependent on target entropy and target measurement covariance. A constant information measure maintains a fixed spectral efficiency to support the RF convergence of radar and communications. The result is a radar implementing a novel target scheduling algorithm based on information instead of heuristic or ad hoc methods. The CIR mathematically ensures that spectral use is justified.

ContributorsPaul, Bryan (Author) / Bliss, Daniel (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2016-09-19
128723-Thumbnail Image.png
Description

Recent studies have reported a greater prevalence of spin turns, which are more unstable than step turns, in older adults compared to young adults in laboratory settings. Currently, turning strategies can only be identified through visual observation, either in-person or through video. This paper presents two unique methods and their

Recent studies have reported a greater prevalence of spin turns, which are more unstable than step turns, in older adults compared to young adults in laboratory settings. Currently, turning strategies can only be identified through visual observation, either in-person or through video. This paper presents two unique methods and their combination to remotely monitor turning behavior using three uniaxial gyroscopes. Five young adults performed 90° turns at slow, normal, and fast walking speeds around a variety of obstacles while instrumented with three IMUs (attached on the trunk, left and right shank). Raw data from 360 trials were analyzed. Compared to visual classification, the two IMU methods’ sensitivity/specificity to detecting spin turns were 76.1%/76.7% and 76.1%/84.4%, respectively. When the two methods were combined, the IMU had an overall 86.8% sensitivity and 92.2% specificity, with 89.4%/100% sensitivity/specificity at slow speeds. This combined method can be implemented into wireless fall prevention systems and used to identify increased use of spin turns. This method allows for longitudinal monitoring of turning strategies and allows researchers to test for potential associations between the frequency of spin turns and clinically relevant outcomes (e.g., falls) in non-laboratory settings.

ContributorsFino, Peter C. (Author) / Frames, Christopher W. (Author) / Lockhart, Thurmon (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-05-06
128727-Thumbnail Image.png
Description

Presented in this paper is a bi-directional out-of-plane actuator which combines the merits of the electrostatic repulsive principle and the electrostatic attractive principle. By taking advantage of the electrostatic repulsive mode, the common “pull-in” instability can be lessened to enlarge the displacement, and by applying the electrostatic attractive mode, the

Presented in this paper is a bi-directional out-of-plane actuator which combines the merits of the electrostatic repulsive principle and the electrostatic attractive principle. By taking advantage of the electrostatic repulsive mode, the common “pull-in” instability can be lessened to enlarge the displacement, and by applying the electrostatic attractive mode, the out-of-plane displacement is further enlarged. The implications of changing the actuator’s physical dimensions are discussed, along with the two-layer polysilicon surface microfabrication process used to fabricate such an actuator. The static characteristics of the out-of-plane displacement versus the voltage of both modes are tested, and displacements of 1.4 μm and 0.63 μm are obtained at 130 V and 15 V, respectively. Therefore, a total stroke of 2.03 μm is achieved, more than 3 fold that of the electrostatic attractive mode, making this actuator useful in optical Micro-Electro-Mechanical Systems (MEMS) and Radio Frequency (RF) MEMS applications.

ContributorsRen, Hao (Author) / Wang, Weimin (Author) / Tao, Fenggang (Author) / Yao, Jun (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2013-12-05
128735-Thumbnail Image.png
Description

The R-specific alcohol dehydrogenase (ADH) from Lactobacillus brevis LB19 (LbADH) was studied with respect to its ability to reduce a series of 3- through 5-carbon 2-alkanones and aldehydes of relevance as biofuel precursors. Although active on all substrates tested, LbADH displays a marked preference for longer chain substrates. Interestingly, however,

The R-specific alcohol dehydrogenase (ADH) from Lactobacillus brevis LB19 (LbADH) was studied with respect to its ability to reduce a series of 3- through 5-carbon 2-alkanones and aldehydes of relevance as biofuel precursors. Although active on all substrates tested, LbADH displays a marked preference for longer chain substrates. Interestingly, however, 2-alkanones were found to impose substrate inhibition towards LbADH, whereas aldehyde substrates rendered no such effect. Inhibition caused by 2-alkanones was furthermore found to intensify with increasing chain length. Despite demonstrating both primary and secondary ADH activities, a preliminary sequence analysis suggests that LbADH remains distinct from other, previously characterized primary-secondary ADHs. In addition to further characterizing the substrate range of this industrially important enzyme, this study suggests that LbADH has the potential to serve as a useful enzyme for the engineering of various novel alcohol biofuel pathways.

ContributorsHalloum, Ibrahim (Author) / Thompson, Brian (Author) / Pugh, Shawn (Author) / Nielsen, David (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-08-05
128649-Thumbnail Image.png
Description

Misfolding and aggregation of α-synuclein into toxic soluble oligomeric α-synuclein aggregates has been strongly correlated with the pathogenesis of Parkinson’s disease (PD). Here, we show that two different morphologically distinct oligomeric α-synuclein aggregates are present in human post-mortem PD brain tissue and are responsible for the bulk of α-synuclein induced

Misfolding and aggregation of α-synuclein into toxic soluble oligomeric α-synuclein aggregates has been strongly correlated with the pathogenesis of Parkinson’s disease (PD). Here, we show that two different morphologically distinct oligomeric α-synuclein aggregates are present in human post-mortem PD brain tissue and are responsible for the bulk of α-synuclein induced toxicity in brain homogenates from PD samples. Two antibody fragments that selectively bind the different oligomeric α-synuclein variants block this α-synuclein induced toxicity and are useful tools to probe how various cell models replicate the α-synuclein aggregation pattern of human PD brain. Using these reagents, we show that mammalian cell type strongly influences α-synuclein aggregation, where neuronal cells best replicate the PD brain α-synuclein aggregation profile. Overexpression of α-synuclein in the different cell lines increased protein aggregation but did not alter the morphology of the oligomeric aggregates generated. Differentiation of the neuronal cells into a cholinergic-like or dopaminergic-like phenotype increased the levels of oligomeric α-synuclein where the aggregates were localized in cell neurites and cell bodies.

ContributorsXin, Wei (Author) / Emadi, Sharareh (Author) / Williams, Stephanie (Author) / Liu, Qiang (Author) / Schulz, Philip (Author) / He, Ping (Author) / Bahar Alam, Now (Author) / Wu, Jie (Author) / Sierks, Michael (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-07-22
128650-Thumbnail Image.png
Description

Injuries associated with fall incidences continue to pose a significant burden to persons with Parkinson’s disease (PD) both in terms of human suffering and economic loss. Freezing of gait (FOG), which is one of the symptoms of PD, is a common cause of falls in this population. Although a significant

Injuries associated with fall incidences continue to pose a significant burden to persons with Parkinson’s disease (PD) both in terms of human suffering and economic loss. Freezing of gait (FOG), which is one of the symptoms of PD, is a common cause of falls in this population. Although a significant amount of work has been performed to characterize/detect FOG using both qualitative and quantitative methods, there remains paucity of data regarding real-time detection of FOG, such as the requirements for minimum sensor nodes, sensor placement locations, and appropriate sampling period and update time. Here, the continuous wavelet transform (CWT) is employed to define an index for correctly identifying FOG. Since the CWT method uses both time and frequency components of a waveform in comparison to other methods utilizing only the frequency component, we hypothesized that using this method could lead to a significant improvement in the accuracy of FOG detection. We tested the proposed index on the data of 10 PD patients who experience FOG. Two hundred and thirty seven (237) FOG events were identified by the physiotherapists. The results show that the index could discriminate FOG in the anterior-posterior axis better than other two axes, and is robust to the update time variability. These results suggest that real time detection of FOG may be realized by using CWT of a single shank sensor with window size of 2 s and update time of 1 s (82.1% and 77.1% for the sensitivity and specificity, respectively). Although implicated, future studies should examine the utility of this method in real-time detection of FOG.

ContributorsRezvanian, Saba (Author) / Lockhart, Thurmon (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2016-04-02
128654-Thumbnail Image.png
Description

Flexible active matrix display technology has been adapted to create new flexible photo-sensing electronic devices, including flexible X-ray detectors. Monolithic integration of amorphous silicon (a-Si) PIN photodiodes on a flexible substrate poses significant challenges associated with the intrinsic film stress of amorphous silicon. This paper examines how altering device structuring

Flexible active matrix display technology has been adapted to create new flexible photo-sensing electronic devices, including flexible X-ray detectors. Monolithic integration of amorphous silicon (a-Si) PIN photodiodes on a flexible substrate poses significant challenges associated with the intrinsic film stress of amorphous silicon. This paper examines how altering device structuring and diode passivation layers can greatly improve the electrical performance and the mechanical reliability of the device, thereby eliminating one of the major weaknesses of a-Si PIN diodes in comparison to alternative photodetector technology, such as organic bulk heterojunction photodiodes and amorphous selenium. A dark current of 0.5 pA/mm2 and photodiode quantum efficiency of 74% are possible with a pixelated diode structure with a silicon nitride/SU-8 bilayer passivation structure on a 20 µm-thick polyimide substrate.

ContributorsMarrs, Michael (Author) / Raupp, Gregory (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2016-07-26
128656-Thumbnail Image.png
Description

Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor

Rapid bacterial detection using biosensors is a novel approach for microbiological testing applications. Validation of such methods is an obstacle in the adoption of new bio-sensing technologies for water testing. Therefore, establishing a quality assurance and quality control (QA/QC) plan is essential to demonstrate accuracy and reliability of the biosensor method for the detection of E. coli in drinking water samples. In this study, different reagents and assay conditions including temperatures, holding time, E. coli strains and concentrations, dissolving agents, salinity and pH effects, quality of substrates of various suppliers of 4-methylumbelliferyl glucuronide (MUG), and environmental water samples were included in the QA/QC plan and used in the assay optimization and documentation. Furthermore, the procedural QA/QC for the monitoring of drinking water samples was established to validate the performance of the biosensor platform for the detection of E. coli using a culture-based standard technique. Implementing the developed QA/QC plan, the same level of precision and accuracy was achieved using both the standard and the biosensor methods. The established procedural QA/QC for the biosensor will provide a reliable tool for a near real-time monitoring of E. coli in drinking water samples to both industry and regulatory authorities.

ContributorsHesari, Nikou (Author) / Kirathi Yilmazcoban, Nursel (Author) / Elzein, Mohamad (Author) / Alum, Absar (Author) / Abbaszadegan, Morteza (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2017-01-03