Matching Items (480)
Filtering by

Clear all filters

134136-Thumbnail Image.png
Description
Biomarkers are the cornerstone of modern-day medicine. They are defined as any biological substance in or outside the body that gives insight to the body's condition. Doctors and researchers can measure specific biomarkers to diagnose and treat patients, such as the concentration of hemoglobin Alc and its connection to diabetes.

Biomarkers are the cornerstone of modern-day medicine. They are defined as any biological substance in or outside the body that gives insight to the body's condition. Doctors and researchers can measure specific biomarkers to diagnose and treat patients, such as the concentration of hemoglobin Alc and its connection to diabetes. There are a variety of methods, or assays, to detect biomarkers, but the most common assay is enzyme-linked immunosorbent assay (ELISA). A new-generation assay termed mass spectrometric immunoassay (MSIA) can measure proteoforms, the different chemical variations of proteins, and their relative abundance. ELISA on the other hand measures the overall concentration of protein in the sample. Measuring each of the proteoforms of a protein is important because only one or two variations could be biologically significant and/or cause diseases. However, running MSIA is expensive. For this reason, an alternative plate-based MSIA technique was tested for its ability to detect the proteoforms of a protein called apolipoprotein C-III (ApoC-III). This technique combines the protein capturing procedure of ELISA to isolate the protein with detection in a mass spectrometer. A larger amount of ApoC-III present in the body indicates a considerable risk for coronary heart disease. The precision of the assay is determined on the coefficient of variation (CV). A CV value is the ratio of standard deviation in relation to the mean, represented as a percentage. The smaller the percentage, the less variation the assay has, and therefore the more ability it has to detect subtle changes in the biomarker. An accepted CV would be less than 10% for single-day tests (intra-day) and less than 15% for multi-day tests (inter-day). The plate-based MSIA was started by first coating a 96-well round bottom plate with 2.5 micrograms of ApoC-III antibody. Next, a series of steps were conducted: a buffer wash, then the sample incubation, followed by another buffer wash and two consecutive water washes. After the final wash, the wells were filled with a MALDI matrix, then spotted onto a gold plate to dry. The dry gold target was then placed into a MALDI-TOF mass spectrometer to produce mass spectra for each spot. The mass spectra were calibrated and the area underneath each of the four peaks representing the ApoC-III proteoforms was exported as an Excel file. The intra-day CV values were found by dividing the standard deviation by the average relative abundance of each peak. After repeating the same procedure for three more days, the inter-day CVs were found using the same method. After completing the experiment, the CV values were all within the acceptable guidelines. Therefore, the plate-based MSIA is a viable alternative for finding proteoforms than the more expensive MSIA tips. To further validate this, additional tests will need to be conducted with different proteins and number of samples to determine assay flexibility.
ContributorsTieu, Luc (Author) / Borges, Chad (Thesis director) / Nedelkov, Dobrin (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2017-12
134295-Thumbnail Image.png
Description
Brown adipose tissue (BAT) is thought to be important in combating obesity as it can expend energy in the form of heat, e.g. thermogenesis. The goal of this study was to study the effect of injected norepinephrine (NE) on the activation of BAT in rats that were fed a high

Brown adipose tissue (BAT) is thought to be important in combating obesity as it can expend energy in the form of heat, e.g. thermogenesis. The goal of this study was to study the effect of injected norepinephrine (NE) on the activation of BAT in rats that were fed a high fat diet (HFD). A dose of 0.25 mg/kg NE was used to elicit a temperature response that was measured using transponders inserted subcutaneously over the BAT and lower back and intraperitoneally to measure the core temperature. The results found that the thermic effect of the BAT increased after the transition from low fat diet to a high fat diet (LFD) yet, after prolonged exposure to the HFD, the effects resembled levels found with the LFD. This suggests that while a HFD may stimulate the effect of BAT, long term exposure may have adverse effects on BAT activity. This may be due to internal factors that will need to be examined further.
ContributorsSion, Paul William (Author) / Herman, Richard (Thesis director) / Borges, Chad (Committee member) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
134565-Thumbnail Image.png
Description
A numerical study of wave-induced momentum transport across the tropopause in the presence of a stably stratified thin inversion layer is presented and discussed. This layer consists of a sharp increase in static stability within the tropopause. The wave propagation is modeled by numerically solving the Taylor-Goldstein equation, which governs

A numerical study of wave-induced momentum transport across the tropopause in the presence of a stably stratified thin inversion layer is presented and discussed. This layer consists of a sharp increase in static stability within the tropopause. The wave propagation is modeled by numerically solving the Taylor-Goldstein equation, which governs the dynamics of internal waves in stably stratified shear flows. The waves are forced by a flow over a bell shaped mountain placed at the lower boundary of the domain. A perfectly radiating condition based on the group velocity of mountain waves is imposed at the top to avoid artificial wave reflection. A validation for the numerical method through comparisons with the corresponding analytical solutions will be provided. Then, the method is applied to more realistic profiles of the stability to study the impact of these profiles on wave propagation through the tropopause.
Created2017-05
135371-Thumbnail Image.png
Description
Almost every form of cancer deregulates the expression and activity of anabolic glycosyltransferase (GT) enzymes, which incorporate particular monosaccharides in a donor acceptor as well as linkage- and anomer-specific manner to assemble complex and diverse glycans that significantly affect numerous cellular events, including tumorigenesis and metastasis. Because glycosylation is not

Almost every form of cancer deregulates the expression and activity of anabolic glycosyltransferase (GT) enzymes, which incorporate particular monosaccharides in a donor acceptor as well as linkage- and anomer-specific manner to assemble complex and diverse glycans that significantly affect numerous cellular events, including tumorigenesis and metastasis. Because glycosylation is not template-driven, GT deregulation yields heterogeneous arrays of aberrant intact glycan products, some in undetectable quantities in clinical bio-fluids (e.g., blood plasma). Numerous glycan features (e.g., 6 sialylation, β-1,6-branching, and core fucosylation) stem from approximately 25 glycan “nodes:” unique linkage specific monosaccharides at particular glycan branch points that collectively confer distinguishing features upon glycan products. For each node, changes in normalized abundance (Figure 1) may serve as nearly 1:1 surrogate measure of activity for culpable GTs and may correlate with particular stages of carcinogenesis. Complementary to traditional top down glycomics, the novel bottom-up technique applied herein condenses each glycan node and feature into a single analytical signal, quantified by two GC-MS instruments: GCT (time-of-flight analyzer) and GCMSD (transmission quadrupole analyzers). Bottom-up analysis of stage 3 and 4 breast cancer cases revealed better overall precision for GCMSD yet comparable clinical performance of both GC MS instruments and identified two downregulated glycan nodes as excellent breast cancer biomarker candidates: t-Gal and 4,6-GlcNAc (ROC AUC ≈ 0.80, p < 0.05). Resulting from the activity of multiple GTs, t-Gal had the highest ROC AUC (0.88) and lowest ROC p‑value (0.001) among all analyzed nodes. Representing core-fucosylation, glycan node 4,6-GlcNAc is a nearly 1:1 molecular surrogate for the activity of α-(1,6)-fucosyltransferase—a potential target for cancer therapy. To validate these results, future projects can analyze larger sample sets, find correlations between breast cancer stage and changes in t-Gal and 4,6-GlcNAc levels, gauge the specificity of these nodes for breast cancer and their potential role in other cancer types, and develop clinical tests for reliable breast cancer diagnosis and treatment monitoring based on t-Gal and 4,6-GlcNAc.
ContributorsZaare, Sahba (Author) / Borges, Chad (Thesis director) / LaBaer, Joshua (Committee member) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
135360-Thumbnail Image.png
Description
Aberrant glycosylation has been shown to be linked to specific cancers, and using this idea, it was proposed that the levels of glycans in the blood could predict stage I adenocarcinoma. To track this glycosylation, glycan were broken down into glycan nodes via methylation analysis. This analysis utilized information from

Aberrant glycosylation has been shown to be linked to specific cancers, and using this idea, it was proposed that the levels of glycans in the blood could predict stage I adenocarcinoma. To track this glycosylation, glycan were broken down into glycan nodes via methylation analysis. This analysis utilized information from N-, O-, and lipid linked glycans detected from gas chromatography-mass spectrometry. The resulting glycan node-ratios represent the initial quantitative data that were used in this experiment.
For this experiment, two Sets of 50 µl blood plasma samples were provided by NYU Medical School. These samples were then analyzed by Dr. Borges’s lab so that they contained normalized biomarker levels from patients with stage 1 adenocarcinoma and control patients with matched age, smoking status, and gender were examined. An ROC curve was constructed under individual and paired conditions and AUC calculated in Wolfram Mathematica 10.2. Methods such as increasing size of training set, using hard vs. soft margins, and processing biomarkers together and individually were used in order to increase the AUC. Using a soft margin for this particular data set was proved to be most useful compared to the initial set hard margin, raising the AUC from 0.6013 to 0.6585. In regards to which biomarkers yielded the better value, 6-Glc/6-Man and 3,6-Gal glycan node ratios had the best with 0.7687 AUC and a sensitivity of .7684 and specificity of .6051. While this is not enough accuracy to become a primary diagnostic tool for diagnosing stage I adenocarcinoma, the methods examined in the paper should be evaluated further. . By comparison, the current clinical standard blood test for prostate cancer that has an AUC of only 0.67.
ContributorsDe Jesus, Celine Spicer (Author) / Taylor, Thomas (Thesis director) / Borges, Chad (Committee member) / School of Mathematical and Statistical Sciences (Contributor) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
134770-Thumbnail Image.png
Description
Disturbances in the protein interactome often play a large role in cancer progression. Investigation of protein-protein interactions (PPI) can increase our understanding of cancer pathways and will disclose unknown targets involved in cancer disease biology. Although numerous methods are available to study protein interactions, most platforms suffer from drawbacks including

Disturbances in the protein interactome often play a large role in cancer progression. Investigation of protein-protein interactions (PPI) can increase our understanding of cancer pathways and will disclose unknown targets involved in cancer disease biology. Although numerous methods are available to study protein interactions, most platforms suffer from drawbacks including high false positive rates, low throughput, and lack of quantification. Moreover, most methods are not compatible for use in a clinical setting. To address these limitations, we have developed a multiplexed, in-solution protein microarray (MISPA) platform with broad applications in proteomics. MISPA can be used to quantitatively profile PPIs and as a robust technology for early detection of cancers. This method utilizes unique DNA barcoding of individual proteins coupled with next generation sequencing to quantitatively assess interactions via barcode enrichment. We have tested the feasibility of this technology in the detection of patient immune responses to oropharyngeal carcinomas and in the discovery of novel PPIs in the B-cell receptor (BCR) pathway. To achieve this goal, 96 human papillomavirus (HPV) antigen genes were cloned into pJFT7-cHalo (99% success) and pJFT7-n3xFlag-Halo (100% success) expression vectors. These libraries were expressed via a cell-free in vitro transcription-translation system with 93% and 96% success, respectively. A small-scale study of patient serum interactions with barcoded HPV16 antigens was performed and a HPV proteome-wide study will follow using additional patient samples. In addition, 15 query proteins were cloned into pJFT7_nGST expression vectors, expressed, and purified with 93% success to probe a library of 100 BCR pathway proteins and detect novel PPIs.
ContributorsRinaldi, Capria Lakshmi (Author) / LaBaer, Joshua (Thesis director) / Mangone, Marco (Committee member) / Borges, Chad (Committee member) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
168413-Thumbnail Image.png
Description
Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size

Microfluidic platforms have been exploited extensively as a tool for the separation of particles by electric field manipulation. Microfluidic devices can facilitate the manipulation of particles by dielectrophoresis. Separation of particles by size and type has been demonstrated by insulator-based dielectrophoresis in a microfluidic device. Thus, manipulating particles by size has been widely studied throughout the years. It has been shown that size-heterogeneity in organelles has been linked to multiple diseases from abnormal organelle size. Here, a mixture of two sizes of polystyrene beads (0.28 and 0.87 μm) was separated by a ratchet migration mechanism under a continuous flow (20 nL/min). Furthermore, to achieve high-throughput separation, different ratchet devices were designed to achieve high-volume separation. Recently, enormous efforts have been made to manipulate small size DNA and proteins. Here, a microfluidic device comprising of multiple valves acting as insulating constrictions when a potential is applied is presented. The tunability of the electric field gradient is evaluated by a COMSOL model, indicating that high electric field gradients can be reached by deflecting the valve at a certain distance. Experimentally, the tunability of the dynamic constriction was demonstrated by conducting a pressure study to estimate the gap distance between the valve and the substrate at different applied pressures. Finally, as a proof of principle, 0.87 μm polystyrene beads were manipulated by dielectrophoresis. These microfluidic platforms will aid in the understanding of size-heterogeneity of organelles for biomolecular assessment and achieve separation of nanometer-size DNA and proteins by dielectrophoresis.
ContributorsOrtiz, Ricardo (Author) / Ros, Alexandra (Thesis advisor) / Hayes, Mark (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2021
171514-Thumbnail Image.png
Description
Plasma and serum are the most commonly used liquid biospecimens in biomarker research. These samples may be subjected to several pre-analytical variables (PAVs) during collection, processing and storage. Exposure to thawed conditions (temperatures above -30 °C) is a PAV that is hard to control, and track and could provide misleading

Plasma and serum are the most commonly used liquid biospecimens in biomarker research. These samples may be subjected to several pre-analytical variables (PAVs) during collection, processing and storage. Exposure to thawed conditions (temperatures above -30 °C) is a PAV that is hard to control, and track and could provide misleading information, that fail to accurately reveal the in vivo biological reality, when unaccounted for. Hence, assays that can empirically check the integrity of plasma and serum samples are crucial. As a solution to this issue, an assay titled ΔS-Cys-Albumin was developed and validated. The reference range of ΔS-Cys-Albumin in cardio vascular patients was determined and the change in ΔS-Cys-Albumin values in different samples over time course incubations at room temperature, 4 °C and -20 °C were evaluated. In blind challenges, this assay proved to be successful in identifying improperly stored samples individually and as groups. Then, the correlation between the instability of several clinically important proteins in plasma from healthy and cancer patients at room temperature, 4 °C and -20 °C was assessed. Results showed a linear inverse relationship between the percentage of proteins destabilized and ΔS-Cys-Albumin regardless of the specific time or temperature of exposure, proving ΔS-Cys-Albumin as an effective surrogate marker to track the stability of clinically relevant analytes in plasma. The stability of oxidized LDL in serum at different temperatures was assessed in serum samples and it stayed stable at all temperatures evaluated. The ΔS-Cys-Albumin requires the use of an LC-ESI-MS instrument which limits its availability to most clinical research laboratories. To overcome this hurdle, an absorbance-based assay that can be measured using a plate reader was developed as an alternative to the ΔS-Cys-Albumin assay. Assay development and analytical validation procedures are reported herein. After that, the range of absorbance in plasma and serum from control and cancer patients were determined and the change in absorbance over a time course incubation at room temperature, 4 °C and -20 °C was assessed. The results showed that the absorbance assay would act as a good alternative to the ΔS-Cys-Albumin assay.
ContributorsJehanathan, Nilojan (Author) / Borges, Chad (Thesis advisor) / Guo, Jia (Committee member) / Van Horn, Wade (Committee member) / Arizona State University (Publisher)
Created2022
189213-Thumbnail Image.png
Description
This work presents a thorough analysis of reconstruction of global wave fields (governed by the inhomogeneous wave equation and the Maxwell vector wave equation) from sensor time series data of the wave field. Three major problems are considered. First, an analysis of circumstances under which wave fields can be fully

This work presents a thorough analysis of reconstruction of global wave fields (governed by the inhomogeneous wave equation and the Maxwell vector wave equation) from sensor time series data of the wave field. Three major problems are considered. First, an analysis of circumstances under which wave fields can be fully reconstructed from a network of fixed-location sensors is presented. It is proven that, in many cases, wave fields can be fully reconstructed from a single sensor, but that such reconstructions can be sensitive to small perturbations in sensor placement. Generally, multiple sensors are necessary. The next problem considered is how to obtain a global approximation of an electromagnetic wave field in the presence of an amplifying noisy current density from sensor time series data. This type of noise, described in terms of a cylindrical Wiener process, creates a nonequilibrium system, derived from Maxwell’s equations, where variance increases with time. In this noisy system, longer observation times do not generally provide more accurate estimates of the field coefficients. The mean squared error of the estimates can be decomposed into a sum of the squared bias and the variance. As the observation time $\tau$ increases, the bias decreases as $\mathcal{O}(1/\tau)$ but the variance increases as $\mathcal{O}(\tau)$. The contrasting time scales imply the existence of an ``optimal'' observing time (the bias-variance tradeoff). An iterative algorithm is developed to construct global approximations of the electric field using the optimal observing times. Lastly, the effect of sensor acceleration is considered. When the sensor location is fixed, measurements of wave fields composed of plane waves are almost periodic and so can be written in terms of a standard Fourier basis. When the sensor is accelerating, the resulting time series is no longer almost periodic. This phenomenon is related to the Doppler effect, where a time transformation must be performed to obtain the frequency and amplitude information from the time series data. To obtain frequency and amplitude information from accelerating sensor time series data in a general inhomogeneous medium, a randomized algorithm is presented. The algorithm is analyzed and example wave fields are reconstructed.
ContributorsBarclay, Bryce Matthew (Author) / Mahalov, Alex (Thesis advisor) / Kostelich, Eric J (Thesis advisor) / Moustaoui, Mohamed (Committee member) / Motsch, Sebastien (Committee member) / Platte, Rodrigo (Committee member) / Arizona State University (Publisher)
Created2023
187871-Thumbnail Image.png
Description
Trace evidence is an essential component of forensic investigations. Anthropogenicmaterials such as fibers and glass have been well studied for use in forensic trace evidence, but the potential use of retroreflective beads found in soils for forensic investigations is largely unexplored. Retroreflective glass beads are tiny spheres mixed into pavement

Trace evidence is an essential component of forensic investigations. Anthropogenicmaterials such as fibers and glass have been well studied for use in forensic trace evidence, but the potential use of retroreflective beads found in soils for forensic investigations is largely unexplored. Retroreflective glass beads are tiny spheres mixed into pavement markings to create reflective surfaces to reduce lane departure accidents. Retroreflective glass beads are a potentially new source of trace evidence for forensic investigations. Analysis of the spatial distribution and chemical compositions of retroreflective glass beads recovered from 17 soil samples were analyzed and compared to see if there are striking variations that can distinguish samples by source. Soil samples taken near marked roads showed significantly higher concentrations of glass beads, averaging from 0.18 bead/g of soil sample to 587 beads/g of soil, while soil samples taken near unmarked roads had average range of concentration of 0 bead/g of soil to 0.21 bead/g of soil. Retroreflective glass beads come from pavement markings, thus soil samples near marked roads are expected to have higher concentrations of glass beads. Analysis of spatial distribution of glass beads showed that as sample collection moved further from the road, concentration of glass beads decreased. ICP-MS results of elemental concentrations for each sample showed discriminative differences between samples, for most of the elements. An analysis of variance for elemental concentrations was conducted, and results showed statistically significant differences, beyond random chance alone for half of the elements analyzed. For forensic comparisons, a significant difference in even just one element is enough to conclude that the samples came from different sources. The elemental concentrations of glass beads collected from the same location, but of varying differences, was also analyzed. ANOVA results show significant differences for only one or two elements. A pair-wise t-test was conducted to determine which elements are most discriminative among all the samples. Rubidium was found to be the most discriminative, showing significant difference for 67% of the pairs. Beryllium, potassium, and manganese were also highly discriminative, showing significant difference for at least 50% of all the pairs.
ContributorsGomez, Janelle Kate Pacifico (Author) / Montero, Shirly (Thesis advisor) / Herckes, Pierre (Thesis advisor) / Borges, Chad (Committee member) / Gordon, Gwyneth (Committee member) / Arizona State University (Publisher)
Created2023