Matching Items (14)
Filtering by

Clear all filters

150048-Thumbnail Image.png
Description
A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene,

A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene, and xylenes (BTEX) via a homemade molecular imprinted polymer, and a specific detection and control circuit. The device is a wireless, portable, battery-powered, and cell-phone operated device. The device has been calibrated and validated in the laboratory and using selected ion flow tube mass spectrometry (SFIT-MS). The capability and robustness are also demonstrated in some field tests. It provides rapid and reliable detection of BTEX in real samples, including challenging high concentrations of interferents, and it is suitable for occupational, environmental health and epidemiological applications.
ContributorsChen, Zheng (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
151765-Thumbnail Image.png
Description
An imaging measurement technique is developed using surface plasmon resonance. Plasmonic-based electrochemical current imaging (P-ECi) method has been developed to image the local electrochemical current optically, it allows us to measure the current density quickly and non-invasively [1, 2]. In this thesis, we solve the problems when we extand the

An imaging measurement technique is developed using surface plasmon resonance. Plasmonic-based electrochemical current imaging (P-ECi) method has been developed to image the local electrochemical current optically, it allows us to measure the current density quickly and non-invasively [1, 2]. In this thesis, we solve the problems when we extand the P-ECi technique to the field of thin film system. The P-ECi signal in thin film structure was found to be directly proportional to the electrochemical current. The upper-limit of thin film thickness to use the proportional relationship between P-ECi signal and EC current was discussed by experiment and simulation. Furthermore, a new algorithm which can calculate the current density from P-ECi signal without any thickness limitation is developed and tested. Besides, surface plasmon resonance is useful phenomenon which can be used to detect the changes in the refractive index near the gold sensing surface. With the assistance of pH indicator, by applied EC potential on the gold film as the working electrode, the detection of H2 evolution reaction can be enhanced. This measurement technique is useful in analyzing local EC information and H2 evolution. References [1] S. Wang, et al., "Electrochemical Surface Plasmon Resonance: Basic Formalism and Experimental Validation," Analytical Chemistry, vol. 82, pp. 935-941, 2010/02/01 2010. [2] X. Shan, et al., "Imaging Local Electrochemical Current via Surface Plasmon Resonance," Science, vol. 327, pp. 1363-1366, March 12, 2010 2010.
ContributorsZhao, Yanjun (Author) / Tao, Nongjian (Thesis advisor) / Wang, Shaopeng (Committee member) / Tsow, Tsing (Committee member) / Arizona State University (Publisher)
Created2013
152020-Thumbnail Image.png
Description
The purpose of this pilot randomized control trial was to test the initial efficacy of a 10 week social cognitive theory (SCT)-based intervention to reduce workplace sitting time (ST). Participants were currently employed adults with predominantly sedentary occupations (n=24) working in the Greater Phoenix area in 2012-2013. Participants wore an

The purpose of this pilot randomized control trial was to test the initial efficacy of a 10 week social cognitive theory (SCT)-based intervention to reduce workplace sitting time (ST). Participants were currently employed adults with predominantly sedentary occupations (n=24) working in the Greater Phoenix area in 2012-2013. Participants wore an activPAL (AP) inclinometer to assess postural allocation (i.e., sitting vs. standing) and Actigraph accelerometer (AG) to assess sedentary time for one week prior to beginning and immediately following the completion of the 10 week intervention. Self-reported measures of sedentary time were obtained via two validated questionnaires for overall (International Physical Activity Questionnaire [IPAQ]) and domain specific sedentary behaviors (Sedentary Behavior Questionnaire [SBQ]). SCT constructs were also measured pre and post via adapted physical activity questionnaires. Participants were randomly assigned to receive either (a) 10 weekly social cognitive-based e-newsletters focused on reducing workplace ST; or (b) similarly formatted 10 weekly e-newsletters focusing on health education. Baseline adjusted Analysis of Covariance statistical analyses were used to examine differences between groups in time spent sitting (AP) and sedentary (AG) during self-reported work hours from pre- to post- intervention. Both groups decreased ST and AG sedentary time; however, no significant differences were observed. SCT constructs also did not change significantly between pretest and post test in either group. These results indicate that individualized educational approaches to decreasing workplace sitting time may not be sufficient for observing long term change in behaviors. Future research should utilize a larger sample, measure main outcomes more frequently, and incorporate more environmental factors throughout the intervention.
ContributorsGordon, Amanda (Author) / Buman, Matthew (Thesis advisor) / Der Ananian, Cheryl (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2013
151927-Thumbnail Image.png
Description
INTRODUCTION: Exercise performed at moderate to vigorous intensities has been shown to generate a post exercise hypotensive response. Whether this response is observed with very low exercise intensities is unclear. PURPOSE: To compare post physical activity ambulatory blood pressure (ABP) response to a single worksite walking day and a normal

INTRODUCTION: Exercise performed at moderate to vigorous intensities has been shown to generate a post exercise hypotensive response. Whether this response is observed with very low exercise intensities is unclear. PURPOSE: To compare post physical activity ambulatory blood pressure (ABP) response to a single worksite walking day and a normal sedentary work day in pre-hypertensive adults. METHODS: Participants were 7 pre-hypertensive (127 + 8 mmHg / 83 + 8 mmHg) adults (3 male, 4 female, age = 42 + 12 yr) who participated in a randomized, cross-over study that included a control and a walking treatment. Only those who indicated regularly sitting at least 8 hours/day and no structured physical activity were enrolled. Treatment days were randomly assigned and were performed one week apart. Walking treatment consisted of periodically increasing walk time up to 2.5 hours over the course of an 8 hour work day on a walking workstation (Steelcase Company, Grand Rapids, MI). Walk speed was set at 1 mph. Participants wore an ambulatory blood pressure cuff (Oscar 2, SunTech Medical, Morrisville, NC) for 24-hours on both treatment days. Participants maintained normal daily activities on the control day. ABP data collected from 9:00 am until 10:00 pm of the same day were included in statistical analyses. Linear mixed models were used to detect differences in systolic (SBP) and diastolic blood pressure (DBP) by treatment condition over the whole day and post workday for the time periods between 4 -10 pm when participants were no longer at work. RESULTS:BP was significantly lower in response to the walking treatment compared to the control day (Mean SBP 126 +7 mmHg vs.124 +7 mmHg, p=.043; DBP 80 + 3 mmHg vs. 77 + 3 mmHg, p = 0.001 respectively). Post workday (4:00 to 10:00 pm) SBP decreased 3 mmHg (p=.017) and DBP decreased 4 mmHg (p<.001) following walking. CONCLUSION: Even low intensity exercise such as walking on a walking workstation is effective for significantly reducing acute BP when compared to a normal work day.
ContributorsZeigler, Zachary (Author) / Swan, Pamela (Thesis advisor) / Buman, Matthew (Committee member) / Gaesser, Glenn (Committee member) / Arizona State University (Publisher)
Created2013
150905-Thumbnail Image.png
Description
This work demonstrates the integration of a wearable particulate detector and a wireless chemical sensor into a single portable system. The detection philosophy of the chemical sensor is based on highly selective and sensitive microfabricated quartz tuning fork arrays and the particle detector detects the particulate level in real-time using

This work demonstrates the integration of a wearable particulate detector and a wireless chemical sensor into a single portable system. The detection philosophy of the chemical sensor is based on highly selective and sensitive microfabricated quartz tuning fork arrays and the particle detector detects the particulate level in real-time using a nephelometric (light scattering) approach. The device integration is realized by carefully evaluating the needs of flow rate, power and data collection. Validation test has been carried out in both laboratory and in field trials such as parking structures and highway exits with high and low traffic emissions. The integrated single portable detection system is capable of reducing the burden for a child to carry multiple devices, simplifying the task of researchers to synchronize and analyze data from different sensors, and minimizing the overall weight, size, and cost of the sensor. It also has a cell phone for data analysis, storage, and transmission as a user-friendly interface. As the chemical and particulate levels present important exposure risks that are of high interests to epidemiologists, the integrated device will provide an easier, wearable and cost effective way to monitor it.
ContributorsGao, Tianle (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Tsow, Tsing (Committee member) / Arizona State University (Publisher)
Created2012
150596-Thumbnail Image.png
Description
Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This

Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This work involves development of an innovative mobile health system with adaptive biofeedback mechanism and demonstrates the importance of biofeedback in accurate measurements of physiological parameters to facilitate the diagnosis in mobile health systems. Resting Metabolic Rate (RMR) assessment, a key aspect in the treatment of diet related health problems is considered as a model to demonstrate the importance of adaptive biofeedback in mobile health. A breathing biofeedback mechanism has been implemented with digital signal processing techniques for real-time visual and musical guidance to accurately measure the RMR. The effects of adaptive biofeedback with musical and visual guidance were assessed on 22 healthy subjects (12 men, 10 women). Eight RMR measurements were taken for each subject on different days under same conditions. It was observed the subjects unconsciously followed breathing biofeedback, yielding consistent and accurate measurements for the diagnosis. The coefficient of variation of the measured metabolic parameters decreased significantly (p < 0.05) for 20 subjects out of 22 subjects.
ContributorsKrishnan, Ranganath (Author) / Tao, Nongjian (Thesis advisor) / Forzani, Erica (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
150839-Thumbnail Image.png
Description
Windows based mobile application for m-health and environmental monitoring sensor devices were developed and tested. With the number of smartphone users exponentially increasing, the applications developed for m-health and environmental monitoring devices are easy to reach the general public, if the applications are simple, user-friendly and personalized. The sensing device

Windows based mobile application for m-health and environmental monitoring sensor devices were developed and tested. With the number of smartphone users exponentially increasing, the applications developed for m-health and environmental monitoring devices are easy to reach the general public, if the applications are simple, user-friendly and personalized. The sensing device uses Bluetooth to communicate with the smartphone, providing mobility to the user. Since the device is small and hand-held, the user can put his smartphone in his pocket, connected to the device in his hand and can move anywhere with it. The data processing performed in the applications is verified against standard off the shelf software, the results of the tests are discussed in this document. The user-interface is very simple and doesn't require many inputs from the user other than during the initial setting when they have to enter their personal information for the records. The m-health application can be used by doctors as well as by patients. The response of the application is very quick and hence the patients need not wait for a long time to see the results. The environmental monitoring device has a real-time plot displayed on the screen of the smartphone showing concentrations of total volatile organic compounds and airborne particle count in the environment at the location of the device. The programming was done with Microsoft Visual Studio and was written on VB.NET platform. On the applications, the smartphone receives data as raw binary bytes from the device via Bluetooth and this data is processed to obtain the final result. The final result is the concentration of Nitric Oxide in ppb in the Asthma Analyzer device. In the environmental monitoring device, the final result is the concentration of total Volatile Organic Compounds and the count of airborne Particles.
ContributorsGanesan, Srisivapriya (Author) / Tao, Nongjian (Thesis advisor) / Zhang, Yanchao (Committee member) / Tsow, Tsing (Committee member) / Arizona State University (Publisher)
Created2012
156842-Thumbnail Image.png
Description
Most drugs work by binding to receptors on the cell surface. These receptors can then carry the message into the cell and have a wide array of results. However, studying how fast the binding is can be difficult. Current methods involve extracting the receptor and labeling them, but both these

Most drugs work by binding to receptors on the cell surface. These receptors can then carry the message into the cell and have a wide array of results. However, studying how fast the binding is can be difficult. Current methods involve extracting the receptor and labeling them, but both these steps have issues. Previous works found that binding on the cell surface is accompanied with a small change in cell size, generally an increase. They have also developed an algorithm that can track these small changes without a label using a simple bright field microscope. Here, this relationship is further explored by comparing edge tracking results to a more widely used method, surface plasmon resonance. The kinetic constants found from the two methods are in agreement. No corrections or manipulations were needed to create agreement. The Bland-Altman plots shows that the error between the two methods is about 0.009 s-1. This is about the same error between cells, making it a non-dominant source of error.
ContributorsHunt, Ashley (Author) / Tao, Nongjian (Thesis advisor) / Ros, Alexandra (Committee member) / Borges, Chad (Committee member) / Arizona State University (Publisher)
Created2018
153970-Thumbnail Image.png
Description
This study examines cognitive and motor function in typical older adults following acute exercise. Ten older adults (Mage = 65.1) completed a single session of assisted cycling (AC) (i.e., exercise accomplished through the use of a motor), voluntary cycling (VC) (self-selected cadence), and a no cycling (NC) control group.

This study examines cognitive and motor function in typical older adults following acute exercise. Ten older adults (Mage = 65.1) completed a single session of assisted cycling (AC) (i.e., exercise accomplished through the use of a motor), voluntary cycling (VC) (self-selected cadence), and a no cycling (NC) control group. These sessions were randomized and separated by approximately one week. Both ACT and VC groups rode a stationary bicycle for 30-minutes each session. These sessions were separated by at least two days. Participants completed cognitive testing that assessed information processing and set shifting and motor testing including gross and fine motor performance at the beginning and at the end of each session. Consistent with our hypothesis concerning manual dexterity, the results showed that manual dexterity improved following the ACT session more than the VC or NC sessions. Improvements in set shifting were also found for the ACT session but not for the VC or NC sessions. The results are interpreted with respect to improvements in neurological function in older adults following acute cycling exercise. These improvements are balance, manual dexterity, and set shifting which have a positive effects on activities of daily living; such as, decrease risk of falls, improve movements like eating and handwriting, and increase ability to multitask.
ContributorsSemken, Keith (Author) / Ringenbach, Shannon (Thesis advisor) / Der Ananian, Cheryl (Committee member) / Buman, Matthew (Committee member) / Arizona State University (Publisher)
Created2015
152481-Thumbnail Image.png
Description
The purpose of this study was to examine whether a workplace environmental intervention would improve work-related outcomes including productivity, presenteeism and cognition. The secondary aim was to investigate whether work-related outcomes are correlated to observed changes in sitting time, physical activity, and sleep. The study was introduced as part of

The purpose of this study was to examine whether a workplace environmental intervention would improve work-related outcomes including productivity, presenteeism and cognition. The secondary aim was to investigate whether work-related outcomes are correlated to observed changes in sitting time, physical activity, and sleep. The study was introduced as part of a naturalistic environmental change in which university staff and faculty were relocated into a new building (n=23). The comparison group consisted of university staff within the same college with no imminent plans to re-locate during the intervention period; there were no environmental changes to this workplace (n =10). Participants wore two behavioral monitoring devices, activPAL and GeneActiv, for 7 consecutive days at two time points (immediately prior and 16 weeks following the office relocation). Measures of productivity and presenteeism were obtained via four validated questionnaires and participants underwent cognitive performance testing. Baseline adjusted analysis of covariance statistical analyses were used to examine differences between groups in work-related outcomes. A residual analysis in regression was conducted to determine the differences between observed changes in sitting time, physical activity and sleep, and work-related outcomes. The results showed that a reduction in work hour sitting time was not detrimental to work related outcomes. Decreased sitting was observed to potentially improve presenteeism and absenteeism. Additionally, physical activity was shown to modestly improve productivity, presenteeism and absenteeism. Poor sleep patterns were associated with work impairment and increased absenteeism.
ContributorsPark, Anna (Author) / Buman, Matthew (Thesis advisor) / Crespo, Noe (Committee member) / Chisum, Jack (Committee member) / Arizona State University (Publisher)
Created2014