Matching Items (170)
Filtering by

Clear all filters

150615-Thumbnail Image.png
Description
This thesis concerns the impact of energy storage on the power system. The rapidly increasing integration of renewable energy source into the grid is driving greater attention towards electrical energy storage systems which can serve many applications like economically meeting peak loads, providing spinning reserve. Economic dispatch is performed with

This thesis concerns the impact of energy storage on the power system. The rapidly increasing integration of renewable energy source into the grid is driving greater attention towards electrical energy storage systems which can serve many applications like economically meeting peak loads, providing spinning reserve. Economic dispatch is performed with bulk energy storage with wind energy penetration in power systems allocating the generation levels to the units in the mix, so that the system load is served and most economically. The results obtained in previous research to solve for economic dispatch uses a linear cost function for a Direct Current Optimal Power Flow (DCOPF). This thesis uses quadratic cost function for a DCOPF implementing quadratic programming (QP) to minimize the function. A Matlab program was created to simulate different test systems including an equivalent section of the WECC system, namely for Arizo-na, summer peak 2009. A mathematical formulation of a strategy of when to charge or discharge the storage is incorporated in the algorithm. In this thesis various test cases are shown in a small three bus test bed and also for the state of Arizona test bed. The main conclusions drawn from the two test beds is that the use of energy storage minimizes the generation dispatch cost of the system and benefits the power sys-tem by serving the peak partially from stored energy. It is also found that use of energy storage systems may alleviate the loading on transmission lines which can defer the upgrade and expansion of the transmission system.
ContributorsGupta, Samir (Author) / Heydt, Gerald T (Thesis advisor) / Vittal, Vijay (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2012
150856-Thumbnail Image.png
Description
Voltage stability is always a major concern in power system operation. Recently Fault Induced Delayed Voltage Recovery (FIDVR) has gained increased attention. It is widely believed that the motor-driven loads of high efficiency, low inertia air conditioners are one of the main causes of FIDVR events. Simulation tools that assist

Voltage stability is always a major concern in power system operation. Recently Fault Induced Delayed Voltage Recovery (FIDVR) has gained increased attention. It is widely believed that the motor-driven loads of high efficiency, low inertia air conditioners are one of the main causes of FIDVR events. Simulation tools that assist power system operation and planning have been found insufficient to reproduce FIDVR events. This is because of their inaccurate load modeling of single-phase motor loads. Conventionally three-phase motor models have been used to represent the aggregation effect of single-phase motor load. However researchers have found that this modeling method is far from an accurate representation of single-phase induction motors. In this work a simulation method is proposed to study the precise influence of single-phase motor load in context of FIDVR. The load, as seen the transmission bus, is replaced with a detailed distribution system. Each single-phase motor in the distribution system is represented by an equipment-level model for best accuracy. This is to enable the simulation to capture stalling effects of air conditioner compressor motors as they are related to FIDVR events. The single phase motor models are compared against the traditional three phase aggregate approximation. Also different percentages of single-phase motor load are compared and analyzed. Simulation result shows that proposed method is able to reproduce FIDVR events. This method also provides a reasonable estimation of the power system voltage stability under the contingencies.
ContributorsMa, Yan (Author) / Karady, George G. (Thesis advisor) / Vittal, Vijay (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2012
150871-Thumbnail Image.png
Description
Determining the factors associated with the availability of healthy and unhealthy foods in the household may help in understanding the varying complexities that contribute to obesity among children and help design interventions to impact children's food consumption behaviors. This study examined factors that are associated with the availability of healthy

Determining the factors associated with the availability of healthy and unhealthy foods in the household may help in understanding the varying complexities that contribute to obesity among children and help design interventions to impact children's food consumption behaviors. This study examined factors that are associated with the availability of healthy and unhealthy foods in children's home food environments (HFE). Data was collected from a random-digit-dial telephone survey of 1708 households, with at least one child between 3-18 years of age, located in five low-income New Jersey cities. HFE was assessed based on responses to a set of six items that measured availability of specific healthy and unhealthy foods in the respondent's home. These items contributed to construction of three HFE scales used as dependent variables in these analyses: healthy HFE, unhealthy HFE, and a ratio of healthy to unhealthy foods in the HFE. Independent variables included household socio-demographics, parental perceptions of their own weight and diet health, frequency of family meals, proximity to food outlets, and perception of access to healthy foods in the neighborhood food environment. Significant differences were observed in the HFE by race and ethnicity, with Non-Hispanic black children having fewer healthy foods and Non-Hispanic white children having more unhealthy food items available at home. Parents who reported being overweight or obese had a healthier HFE and those perceiving their own eating as healthy had more healthy and less unhealthy foods in the household. Food-secure households had more unhealthy compared to healthy foods at home. Households located farther from a supermarket had a greater number of unhealthy food items and a lower healthy/unhealthy food availability ratio. Parental perception of better access to fruits and vegetables and low-fat foods was associated with availability of a greater number of healthy food items at home. Overall, the HFE varied by parental and demographic characteristics, parental perceptions about the food environment and the actual features of the built neighborhood food environment.
ContributorsBerry, Andrea (Author) / Ohri-Vachaspati, Punam (Thesis advisor) / Johnston, Carol (Committee member) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Arizona State University (Publisher)
Created2012
150530-Thumbnail Image.png
Description
With increased usage of green energy, the number of photovoltaic arrays used in power generation is increasing rapidly. Many of the arrays are located at remote locations where faults that occur within the array often go unnoticed and unattended for large periods of time. Technicians sent to rectify the faults

With increased usage of green energy, the number of photovoltaic arrays used in power generation is increasing rapidly. Many of the arrays are located at remote locations where faults that occur within the array often go unnoticed and unattended for large periods of time. Technicians sent to rectify the faults have to spend a large amount of time determining the location of the fault manually. Automated monitoring systems are needed to obtain the information about the performance of the array and detect faults. Such systems must monitor the DC side of the array in addition to the AC side to identify non catastrophic faults. This thesis focuses on two of the requirements for DC side monitoring of an automated PV array monitoring system. The first part of the thesis quantifies the advantages of obtaining higher resolution data from a PV array on detection of faults. Data for the monitoring system can be gathered for the array as a whole or from additional places within the array such as individual modules and end of strings. The fault detection rate and the false positive rates are compared for array level, string level and module level PV data. Monte Carlo simulations are performed using PV array models developed in Simulink and MATLAB for fault and no fault cases. The second part describes a graphical user interface (GUI) that can be used to visualize the PV array for module level monitoring system information. A demonstration GUI is built in MATLAB using data obtained from a PV array test facility in Tempe, AZ. Visualizations are implemented to display information about the array as a whole or individual modules and locate faults in the array.
ContributorsKrishnan, Venkatachalam (Author) / Tepedelenlioğlu, Cihan (Thesis advisor) / Spanias, Andreas (Thesis advisor) / Ayyanar, Raja (Committee member) / Papandreou-Suppappola, Antonia (Committee member) / Arizona State University (Publisher)
Created2012
150495-Thumbnail Image.png
Description
The evaluation of nutritional status by dietary intake assessment is fundamental to nutrition research. Accurate assessment allows for health professional-moderated diet adjustment in order to promote disease prevention and management. However, dietary intake can be extremely challenging to measure properly as reliability and accuracy are essential. As technology use has

The evaluation of nutritional status by dietary intake assessment is fundamental to nutrition research. Accurate assessment allows for health professional-moderated diet adjustment in order to promote disease prevention and management. However, dietary intake can be extremely challenging to measure properly as reliability and accuracy are essential. As technology use has become more prevalent in recent years, an assortment of online, web-based diet analysis methods have begun to emerge. Are these modern methods as accurate as the traditional methods? The aim of this study was to compare and contrast diet analyses from a feeding trial in which both subject-coded (using the Automated Self Administered 24 hour recall, or the ASA24) and investigator-coded (using the Food Processor diet analysis program) diet records were available. Sixty-four overweight (body mass index >27-40 kg/m2) members of a campus community between the ages of 20-45 were recruited for an 8-week parallel arm, randomized controlled trial to evaluate the impact of two different pre-dinner meal snacks on satiety, calories consumed, and contribution to modest weight loss. As part of the study requirements, participants completed 3-day food logs at four different times during the trial: pre-trial, and week 1, 4, and 8. Participants also entered their dietary information into the ASA24 website the day after the intake was recorded by hand. Nutrient intake values were compared between the ASA24 records and the handwritten food logs. All statistical analyses were performed using SPSS Statistical Analysis version 19.0; bivariate analyses and Spearman correlation analyses were utilized. Energy, macronutrient, and micronutrient intakes did correlate significantly between the two methodologies, though both under-reporting and over-reporting were found to exist. Carbohydrate and fiber intakes were under-reported by subjects; retinol, beta-carotene, and vitamin C amounts were over-reported. These results are consistent with previous findings in reporting differences and suggest that the ASA24 is a comparably accurate dietary tracking tool to the traditional diet record method.
ContributorsSchohl, Brooke (Author) / Johnston, Carol (Thesis advisor) / Mayol-Kreiser, Sandra (Committee member) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Arizona State University (Publisher)
Created2012
150520-Thumbnail Image.png
Description
This thesis is focused on the study of wind energy integration and is divided into two segments. The first part of the thesis deals with developing a reliability evaluation technique for a wind integrated power system. A multiple-partial outage model is utilized to accurately calculate the wind generation availability. A

This thesis is focused on the study of wind energy integration and is divided into two segments. The first part of the thesis deals with developing a reliability evaluation technique for a wind integrated power system. A multiple-partial outage model is utilized to accurately calculate the wind generation availability. A methodology is presented to estimate the outage probability of wind generators while incorporating their reduced power output levels at low wind speeds. Subsequently, power system reliability is assessed by calculating the loss of load probability (LOLP) and the effect of wind integration on the overall system is analyzed. Actual generation and load data of the Texas power system in 2008 are used to construct a test case. To demonstrate the robustness of the method, relia-bility studies have been conducted for a fairly constant as well as for a largely varying wind generation profile. Further, the case of increased wind generation penetration level has been simulated and comments made about the usability of the proposed method to aid in power system planning in scenarios of future expansion of wind energy infrastructure. The second part of this thesis explains the development of a graphic user interface (GUI) to demonstrate the operation of a grid connected doubly fed induction generator (DFIG). The theory of DFIG and its back-to-back power converter is described. The GUI illustrates the power flow, behavior of the electrical circuit and the maximum power point tracking of the machine for a variable wind speed input provided by the user. The tool, although developed on MATLAB software platform, has been constructed to work as a standalone application on Windows operating system based computer and enables even the non-engineering students to access it. Results of both the segments of the thesis are discussed. Remarks are presented about the validity of the reliability technique and GUI interface for variable wind speed conditions. Improvements have been suggested to enable the use of the reliability technique for a more elaborate system. Recommendations have been made about expanding the features of the GUI tool and to use it to promote educational interest about renewable power engineering.
ContributorsSinha, Anubhav (Author) / Heydt, Gerald T (Thesis advisor) / Vittal, Vijay (Thesis advisor) / Ayyanar, Raja (Committee member) / Karady, George G. (Committee member) / Arizona State University (Publisher)
Created2012
151013-Thumbnail Image.png
Description
This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs of MV dry-type epoxy insulated CTs were modeled using 3D field simulation software COULOMB® 9.0. Potential and elec-tric fields were calculated based on boundary element

This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs of MV dry-type epoxy insulated CTs were modeled using 3D field simulation software COULOMB® 9.0. Potential and elec-tric fields were calculated based on boundary element method. Different condi-tions such as dry exterior surface, wet exterior surface and internal voids were considered. The research demonstrates that the presence of internal conductors in CTs results in a less severe surface electric field distribution when compared to outdoor insulators of the same voltage range and type. The high electric field near the exited end triple-point of the CT reduces. This remained true even under wet conditions establishing better outdoor performance of CTs than outdoor insulators which have no internal conductors. The effect of internal conductors on voids within the insulation structure was also established. As a down side, internal voids in CTs experience higher electric field stress than in conductor-less insulators. The work recognizes that internal conducting parts in dry type CTs improves their outdoor performance when compared to electrical equipment without internal conductors.
ContributorsLakshmichand Jain, Sandeep Kumar (Author) / Gorur, Ravi (Thesis advisor) / Karady, George G. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2012
151039-Thumbnail Image.png
Description
With the rapid expansion of the photovoltaic industry over the last decade, there has been a huge demand in the PV installations in the residential sector. This thesis focuses on the analysis and implementation of a dc-dc boost converter at photovoltaic sub-module level. The thesis also analyses the various topologies

With the rapid expansion of the photovoltaic industry over the last decade, there has been a huge demand in the PV installations in the residential sector. This thesis focuses on the analysis and implementation of a dc-dc boost converter at photovoltaic sub-module level. The thesis also analyses the various topologies like switched capacitors and extended duty ratio which can be practically implemented in the photovoltaic panels. The results obtained in this work have concentrated on the use of novel strategies to substitute the use of central dc-dc converter used in PV module string connection. The implementation of distributed MPPT at the PV sub-module level is also an integral part of this thesis. Using extensive PLECS simulations, this thesis came to the conclusion that with the design of a proper compensation at the dc interconnection of a series or parallel PV Module Integrated Converter string, the central dc-dc converter can be substituted. The dc-ac interconnection voltage remains regulated at all irradiance level even without a dc-dc central converter at the string end. The foundation work for the hardware implementation has also been carried out. Design of parameters for future hardware implementation has also been presented in detail in this thesis.
ContributorsSen, Sourav (Author) / Ayyanar, Raja (Thesis advisor) / Kiaei, Sayfe (Committee member) / Bakkaloglu, Bertan (Committee member) / Arizona State University (Publisher)
Created2012
151066-Thumbnail Image.png
Description
This thesis concerns with the impact of renewable generation resources on the power system stability. The rapidly increasing integration of renewable energy sources into the grid can change the way power systems operate and respond to system disturbances. This is because the available inertia from synchronous machines, which helps in

This thesis concerns with the impact of renewable generation resources on the power system stability. The rapidly increasing integration of renewable energy sources into the grid can change the way power systems operate and respond to system disturbances. This is because the available inertia from synchronous machines, which helps in damping system oscillations, gets reduced as an increase in renewables like wind and solar photovoltaics is accompanied by a decrease in conventional generators. This aspect of high penetration of renewables has the potential to affect the rotor angle stability and small signal stability of power systems. The system with increased renewables is mathematically modeled to rep-resent wind and solar resources. Transient and small signal stability studies are performed for various operating cases. The main conclusion drawn from the different studies is that increased renewable penetration causes a few instability problems, most of which are either localized and do not adversely affect the over-all system stability. It is also found that the critical inter-area modes of oscillations are sufficiently damped.
ContributorsSingh, Iknoor (Author) / Vittal, Vijay (Thesis advisor) / Ayyanar, Raja (Committee member) / Hedman, Kory (Committee member) / Arizona State University (Publisher)
Created2012
151248-Thumbnail Image.png
Description
Background: Research in animal models suggests that fish oil ingestion may impair immunity and increase risk for infection. To date there are no studies examining this relationship between fish oil ingestion and risk for infection in humans. Objective: The primary aim of this randomized, placebo-controlled, double-blind, parallel-arm study was to

Background: Research in animal models suggests that fish oil ingestion may impair immunity and increase risk for infection. To date there are no studies examining this relationship between fish oil ingestion and risk for infection in humans. Objective: The primary aim of this randomized, placebo-controlled, double-blind, parallel-arm study was to examine the effect of 400 mg of EPA and 200 mg of DHA, the main components of fish oil (FO) supplements, on the incidence of symptoms related to upper respiratory tract infections in healthy young females, at a large southwestern university. Design: Healthy young women between 18 and 38 years of age who were non-obese (mean BMI 23.7 ± 0.6 kg/m2) were recruited from an urban southwestern university campus. Subjects were non-vegetarians, non-smokers, and reported consuming less than one serving (3.5 oz) of fish per week. Participants (n=26) were randomized according to age, body weight, BMI, and daily n-3 fatty acid (FA) intake into two groups: FO (one gel capsule of 600 mg EPA/DHA per day) or CO (one placebo gel capsule of 1000 mg coconut oil per day). Participants completed a validated daily cold symptom survey, the Wisconsin Upper Respiratory Symptom Survey-21 for 8 weeks. Fasting blood samples measuring TNF-α concentrations were taken at weeks 1 and 8, when 24-hour dietary recalls were also performed. Anthropometric measurements were recorded via bioelectrical impedance at trial weeks 1, 4, and 8. Results: The 8-week trial of FO supplementation did not significantly change the average score for perception of cold symptoms between FO and CO groups (167 ± 71 and 185 ± 56, p=0.418, respectively). Plasma TNF-α levels (pg/mL) did not differ between groups (p=0.482). TNF-α levels were significantly correlated with body weight (r=0.480, p=0.037), BMI (r=0.481, p=0.037, and percent body fat (r=0.511, p=0.025) at baseline. Conclusions: Healthy young women taking a fish oil supplement of 400 mg EPA and 200 mg DHA per day over 8 weeks does not impose unintentional health consequences. These findings do not refute the American Heart Association's current recommendations for all Americans to consume two servings (3.5 oz) of a variety of oily fish per week. Depending on the type of fish, this current recommendation equates to approximately 200-300 mg per day of EPA and DHA n-3 polyunsaturated fatty acids. Additional research is needed to investigate the effects of higher dosages of fish oils on daily cold symptoms.
ContributorsGutierrez, Megan (Author) / Johnston, Carol (Thesis advisor) / Appel, Christy (Committee member) / Martin, Keith (Committee member) / Arizona State University (Publisher)
Created2013