Matching Items (6)
Filtering by

Clear all filters

152070-Thumbnail Image.png
Description
When surgical resection becomes necessary to alleviate a patient's epileptiform activity, that patient is monitored by video synchronized with electrocorticography (ECoG) to determine the type and location of seizure focus. This provides a unique opportunity for researchers to gather neurophysiological data with high temporal and spatial resolution; these data are

When surgical resection becomes necessary to alleviate a patient's epileptiform activity, that patient is monitored by video synchronized with electrocorticography (ECoG) to determine the type and location of seizure focus. This provides a unique opportunity for researchers to gather neurophysiological data with high temporal and spatial resolution; these data are assessed prior to surgical resection to ensure the preservation of the patient's quality of life, e.g. avoid the removal of brain tissue required for speech processing. Currently considered the "gold standard" for the mapping of cortex, electrical cortical stimulation (ECS) involves the systematic activation of pairs of electrodes to localize functionally specific brain regions. This method has distinct limitations, which often includes pain experienced by the patient. Even in the best cases, the technique suffers from subjective assessments on the parts of both patients and physicians, and high inter- and intra-observer variability. Recent advances have been made as researchers have reported the localization of language areas through several signal processing methodologies, all necessitating patient participation in a controlled experiment. The development of a quantification tool to localize speech areas in which a patient is engaged in an unconstrained interpersonal conversation would eliminate the dependence of biased patient and reviewer input, as well as unnecessary discomfort to the patient. Post-hoc ECoG data were gathered from five patients with intractable epilepsy while each was engaged in a conversation with family members or clinicians. After the data were separated into different speech conditions, the power of each was compared to baseline to determine statistically significant activated electrodes. The results of several analytical methods are presented here. The algorithms did not yield language-specific areas exclusively, as broad activation of statistically significant electrodes was apparent across cortical areas. For one patient, 15 adjacent contacts along superior temporal gyrus (STG) and posterior part of the temporal lobe were determined language-significant through a controlled experiment. The task involved a patient lying in bed listening to repeated words, and yielded statistically significant activations that aligned with those of clinical evaluation. The results of this study do not support the hypothesis that unconstrained conversation may be used to localize areas required for receptive and productive speech, yet suggests a simple listening task may be an adequate alternative to direct cortical stimulation.
ContributorsLingo VanGilder, Jennapher (Author) / Helms Tillery, Stephen I (Thesis advisor) / Wahnoun, Remy (Thesis advisor) / Buneo, Christopher (Committee member) / Arizona State University (Publisher)
Created2013
150828-Thumbnail Image.png
Description
Effective tactile sensing in prosthetic and robotic hands is crucial for improving the functionality of such hands and enhancing the user's experience. Thus, improving the range of tactile sensing capabilities is essential for developing versatile artificial hands. Multimodal tactile sensors called BioTacs, which include a hydrophone and a force electrode

Effective tactile sensing in prosthetic and robotic hands is crucial for improving the functionality of such hands and enhancing the user's experience. Thus, improving the range of tactile sensing capabilities is essential for developing versatile artificial hands. Multimodal tactile sensors called BioTacs, which include a hydrophone and a force electrode array, were used to understand how grip force, contact angle, object texture, and slip direction may be encoded in the sensor data. Findings show that slip induced under conditions of high contact angles and grip forces resulted in significant changes in both AC and DC pressure magnitude and rate of change in pressure. Slip induced under conditions of low contact angles and grip forces resulted in significant changes in the rate of change in electrode impedance. Slip in the distal direction of a precision grip caused significant changes in pressure magnitude and rate of change in pressure, while slip in the radial direction of the wrist caused significant changes in the rate of change in electrode impedance. A strong relationship was established between slip direction and the rate of change in ratios of electrode impedance for radial and ulnar slip relative to the wrist. Consequently, establishing multiple thresholds or establishing a multivariate model may be a useful method for detecting and characterizing slip. Detecting slip for low contact angles could be done by monitoring electrode data, while detecting slip for high contact angles could be done by monitoring pressure data. Predicting slip in the distal direction could be done by monitoring pressure data, while predicting slip in the radial and ulnar directions could be done by monitoring electrode data.
ContributorsHsia, Albert (Author) / Santos, Veronica J (Thesis advisor) / Santello, Marco (Committee member) / Helms Tillery, Stephen I (Committee member) / Arizona State University (Publisher)
Created2012
150144-Thumbnail Image.png
Description
In the past decade, research on the motor control side of neuroprosthetics has steadily gained momentum. However, modern research in prosthetic development supplements a focus on motor control with a concentration on sensory feedback. Simulating sensation is a central issue because without sensory capabilities, the sophistication of the most advanced

In the past decade, research on the motor control side of neuroprosthetics has steadily gained momentum. However, modern research in prosthetic development supplements a focus on motor control with a concentration on sensory feedback. Simulating sensation is a central issue because without sensory capabilities, the sophistication of the most advanced motor control system fails to reach its full potential. This research is an effort toward the development of sensory feedback specifically for neuroprosthetic hands. The present aim of this work is to understand the processing and representation of cutaneous sensation by evaluating performance and neural activity in somatosensory cortex (SI) during a grasp task. A non-human primate (Macaca mulatta) was trained to reach out and grasp textured instrumented objects with a precision grip. Two different textures for the objects were used, 100% cotton cloth and 60-grade sandpaper, and the target object was presented at two different orientations. Of the 167 cells that were isolated for this experiment, only 42 were recorded while the subject executed a few blocks of successful trials for both textures. These latter cells were used in this study's statistical analysis. Of these, 37 units (88%) exhibited statistically significant task related activity. Twenty-two units (52%) exhibited statistically significant tuning to texture, and 16 units (38%) exhibited statistically significant tuning to posture. Ten of the cells (24%) exhibited statistically significant tuning to both texture and posture. These data suggest that single units in somatosensory cortex can encode multiple phenomena such as texture and posture. However, if this information is to be used to provide sensory feedback for a prosthesis, scientists must learn to further parse cortical activity to discover how to induce specific modalities of sensation. Future experiments should therefore be developed that probe more variables and that more systematically and comprehensively scan somatosensory cortex. This will allow researchers to seek out the existence or non-existence of cortical pockets reserved for certain modalities of sensation, which will be valuable in learning how to later provide appropriate sensory feedback for a prosthesis through cortical stimulation.
ContributorsNaufel, Stephanie (Author) / Helms Tillery, Stephen I (Thesis advisor) / Santos, Veronica J (Thesis advisor) / Buneo, Christopher A (Committee member) / Robert, Jason S (Committee member) / Arizona State University (Publisher)
Created2011
157346-Thumbnail Image.png
Description
Vagal Nerve Stimulation (VNS) has been shown to be a promising therapeutic technique in treating many neurological diseases, including epilepsy, stroke, traumatic brain injury, and migraine headache. The mechanisms by which VNS acts, however, are not fully understood but may involve changes in cerebral blood flow. The vagus nerve plays

Vagal Nerve Stimulation (VNS) has been shown to be a promising therapeutic technique in treating many neurological diseases, including epilepsy, stroke, traumatic brain injury, and migraine headache. The mechanisms by which VNS acts, however, are not fully understood but may involve changes in cerebral blood flow. The vagus nerve plays a significant role in the regulation of heart rate and cerebral blood flow that are altered during VNS. Here, the effects of acute vagal nerve stimulation using varying stimulation parameters on both heart rate and cerebral blood flow were examined. Laser Speckle Contrast Analysis (LASCA) was used to analyze the cerebral blood flow of male Long–Evans rats. In the first experiment, results showed two distinct patterns of responses to 0.8mA of stimulation whereby animals either experienced a mild or severe decrease in heart rate. Further, animals that displayed mild heart rate decreases showed an increase in cerebral blood flow that persisted beyond VNS. Animals that displayed severe decreases showed a transient decrease in cerebral blood flow followed by an increase that was greater than that observed in mild animals but progressively decreased after VNS. The results suggest two distinct patterns of changes in both heart rate and blood flow that may be related to the intensity of VNS. To investigate the effects of lower levels of stimulation, an additional group of animals were stimulated at 0.4mA. The results showed moderate changes in heart rate but no significant changes in cerebral blood flow in these animals. The results demonstrate that VNS alters both heart rate and cerebral blood flow and that these effects are dependent on current intensity.
ContributorsHillebrand, Peter (M.S.) (Author) / Kleim, Jeffrey A (Thesis advisor) / Helms Tillery, Stephen I (Committee member) / Muthuswamy, Jitendran (Committee member) / Arizona State University (Publisher)
Created2019
Description
In the frenzy of next generation genetic sequencing and proteomics, single-cell level analysis has begun to find its place in the crux of personalized medicine and cancer research. Single live cell 3D imaging technology is one of the most useful ways of providing spatial and morphological details inside living single

In the frenzy of next generation genetic sequencing and proteomics, single-cell level analysis has begun to find its place in the crux of personalized medicine and cancer research. Single live cell 3D imaging technology is one of the most useful ways of providing spatial and morphological details inside living single cells. It provides a window to uncover the mysteries of protein structure and folding, as well as genetic expression over time, which will tremendously improve the state of the fields of biophysics and biomedical research. This thesis project specifically demonstrates a method for live single cell rotation required to image them in the single live cell CT imaging platform. The method of rotation proposed in this thesis uses dynamic optical traps generated by a phase-only spatial light modulator (SLM) to exert torque on a single mammalian cell. Laser patterns carrying the holographic information of the traps are delivered from the SLM through a transformation telescope into the objective lens and onto its focal plane to produce the desired optical trap "image". The phase information in the laser patterns being delivered are continuously altered by the SLM such that the structure of the wavefront produces two foci at opposite edges of the cell of interest that each moves along the circumference of the cell in opposite axial directions. Momentum generated by the motion of the foci exerts a torque on the cell, causing it to rotate. The viability of this method was demonstrated experimentally. Software was written using LabVIEW to control the display panel of the SLM.
ContributorsChan, Samantha W (Author) / Meldrum, Deridre R (Thesis advisor) / Kleim, Jeffrey A (Committee member) / Johnson, Roger H (Committee member) / Kelbauskas, Laimonas (Committee member) / Arizona State University (Publisher)
Created2013
157506-Thumbnail Image.png
Description
Stroke remains a leading cause of adult disability in the United States. In recent studies, chronic vagus nerve stimulation (VNS) has been proven to enhance functional recovery when paired with motor rehabilitation training after stroke. Other studies have also demonstrated that delivering VNS during the onset of a

Stroke remains a leading cause of adult disability in the United States. In recent studies, chronic vagus nerve stimulation (VNS) has been proven to enhance functional recovery when paired with motor rehabilitation training after stroke. Other studies have also demonstrated that delivering VNS during the onset of a stroke may elicit some neuroprotective effects as observed in remaining neural tissue and motor function. While these studies have demonstrated the benefits of VNS as a treatment or therapy in combatting stroke damage, the mechanisms responsible for these effects are still not well understood or known. The aim of this research was to further investigate the mechanisms underlying the efficacy of acute VNS treatment of stroke by observing the effect of VNS when applied after the onset of stroke. Animals were randomly assigned to three groups: Stroke animals received cortical ischemia (ET-1 injection), VNS+Stroke animals received acute VNS starting within 48 hours after cortical ischemia and continuing once per day for three days, or Control animals which received neither the injury nor stimulation. Results showed that stroke animals receiving acute VNS had smaller lesion volumes and larger motor cortical maps than those in the Stroke group. The results suggest VNS may confer neuroprotective effects when delivered within the first 96 hours of stroke.
ContributorsOkada, Kristen Yuri (Author) / Kleim, Jeffrey A (Thesis advisor) / Si, Jennie (Thesis advisor) / Helms Tillery, Stephen (Committee member) / Arizona State University (Publisher)
Created2019