Matching Items (69)
Filtering by

Clear all filters

157819-Thumbnail Image.png
Description
As the world becomes more electronic, power electronics designers have continuously designed more efficient converters. However, with the rising number of nonlinear loads (i.e. electronics) attached to the grid, power quality concerns, and emerging legislation, converters that intake alternating current (AC) and output direct current (DC) known as rectifiers are

As the world becomes more electronic, power electronics designers have continuously designed more efficient converters. However, with the rising number of nonlinear loads (i.e. electronics) attached to the grid, power quality concerns, and emerging legislation, converters that intake alternating current (AC) and output direct current (DC) known as rectifiers are increasingly implementing power factor correction (PFC) by controlling the input current. For a properly designed PFC-stage inductor, the major design goals include exceeding minimum inductance, remaining below the saturation flux density, high power density, and high efficiency. In meeting these goals, loss calculation is critical in evaluating designs. This input current from PFC circuitry leads to a DC bias through the filter inductor that makes accurate core loss estimation exceedingly difficult as most modern loss estimation techniques neglect the effects of a DC bias. This thesis explores prior loss estimation and design methods, investigates finite element analysis (FEA) design tools, and builds a magnetics test bed setup to empirically determine a magnetic core’s loss under any electrical excitation. In the end, the magnetics test bed hardware results are compared and future work needed to improve the test bed is outlined.
ContributorsMeyers, Tobin (Author) / Ayyanar, Raja (Thesis advisor) / Qin, Jiangchao (Committee member) / Lei, Qin (Committee member) / Arizona State University (Publisher)
Created2019
158193-Thumbnail Image.png
Description
Energy is one of the wheels on which the modern world runs. Therefore, standards and limits have been devised to maintain the stability and reliability of the power grid. This research shows a simple methodology for increasing the amount of Inverter-based Renewable Generation (IRG), which is also known as Inverter-based

Energy is one of the wheels on which the modern world runs. Therefore, standards and limits have been devised to maintain the stability and reliability of the power grid. This research shows a simple methodology for increasing the amount of Inverter-based Renewable Generation (IRG), which is also known as Inverter-based Resources (IBR), for that considers the voltage and frequency limits specified by the Western Electricity Coordinating Council (WECC) Transmission Planning (TPL) criteria, and the tie line power flow limits between the area-under-study and its neighbors under contingency conditions. A WECC power flow and dynamic file is analyzed and modified in this research to demonstrate the performance of the methodology. GE's Positive Sequence Load Flow (PSLF) software is used to conduct this research and Python was used to analyze the output data.

The thesis explains in detail how the system with 11% of IRG operated before conducting any adjustments (addition of IRG) and what procedures were modified to make the system run correctly. The adjustments made to the dynamic models are also explained in depth to give a clearer picture of how each adjustment affects the system performance. A list of proposed IRG units along with their locations were provided by SRP, a power utility in Arizona, which were to be integrated into the power flow and dynamic files. In the process of finding the maximum IRG penetration threshold, three sensitivities were also considered, namely, momentary cessation due to low voltages, transmission vs. distribution connected solar generation, and stalling of induction motors. Finally, the thesis discusses how the system reacts to the aforementioned modifications, and how IRG penetration threshold gets adjusted with regards to the different sensitivities applied to the system.
ContributorsAlbhrani, Hashem A M H S (Author) / Pal, Anamitra (Thesis advisor) / Holbert, Keith E. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2020
157614-Thumbnail Image.png
Description
Reliable and secure operation of bulk power transmission system components is an important aspect of electric power engineering. Component failures in a transmission network can lead to serious consequences and impact system reliability. The operational health of the transmission assets plays a crucial role in determining the reliability of an

Reliable and secure operation of bulk power transmission system components is an important aspect of electric power engineering. Component failures in a transmission network can lead to serious consequences and impact system reliability. The operational health of the transmission assets plays a crucial role in determining the reliability of an electric grid. To achieve this goal, scheduled maintenance of bulk power system components is an important activity to secure the transmission system against unanticipated events. This thesis identifies critical transmission elements in a 500 kV transmission network utilizing a ranking strategy.

The impact of the failure of transmission assets operated by a major utility company in the Southwest United States on its power system network is studied. A methodology is used to quantify the impact and subsequently rank transmission assets in decreasing order of their criticality. The analysis is carried out on the power system network using a node breaker model and steady state analysis. The light load case of spring 2019, peak load case of summer 2023 and two intermediate load cases have been considered for the ranking. The contingency simulations and power flow studies have been carried out using a commercial power flow study software package, Positive Sequence Load Flow (PSLF). The results obtained from PSLF are analyzed using Matlab to obtain the desired ranking. The ranked list of transmission assets will enable asset managers to identify the assets that have the most significant impact on the overall power system network performance. Therefore, investment and maintenance decisions can be made effectively. A conclusion along with a recommendation for future work is also provided in the thesis.
ContributorsBhandari, Harsh Nandlal (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald T (Thesis advisor) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2019
161459-Thumbnail Image.png
Description
This paper introduces an application space of Power over Ethernet to Universal Serial Bus (USB) Power Delivery, and develops 3 different flyback approaches to a 45 Watt solution in the space. The designs of Fixed Frequency Flyback, Quasi-Resonant Flyback, and Active Clamp Flyback are developed for the application with 37

This paper introduces an application space of Power over Ethernet to Universal Serial Bus (USB) Power Delivery, and develops 3 different flyback approaches to a 45 Watt solution in the space. The designs of Fixed Frequency Flyback, Quasi-Resonant Flyback, and Active Clamp Flyback are developed for the application with 37 Volts (V) to 57 V Direct Current (DC) input voltage and 5 V, 9 V, 15 V, and 20 V output, and results are examined for the given specifications. Implementation based concerns are addressed for each topology during the design process. The systems are proven and tested for efficiency, thermals, and output voltage ripple across the operation range. The topologies are then compared for a cost and benefit analysis and their highlights are identified to showcase each systems prowess.
ContributorsNasir, Anthony Michael (Author) / Ayyanar, Raja (Thesis advisor) / Lei, Qin (Committee member) / Hari, Ajay (Committee member) / Arizona State University (Publisher)
Created2021
161415-Thumbnail Image.png
Description
The broad deployment of time-synchronized continuous point-on-wave (CPoW) modules will enable electric power utilities to gain unprecedented insight into the behavior of their power system assets, loads, and distributed renewable generation in real time. By increasing the available level of detail visible to operators, serious fault events such as wildfire-inducing

The broad deployment of time-synchronized continuous point-on-wave (CPoW) modules will enable electric power utilities to gain unprecedented insight into the behavior of their power system assets, loads, and distributed renewable generation in real time. By increasing the available level of detail visible to operators, serious fault events such as wildfire-inducing arc flashes, safety-jeopardizing transformer failures, and equipment-damaging power quality decline can be mitigated in a data-driven, systematic manner. In this research project, a time-synchronized micro-scale CPoW module was designed, constructed, and characterized. This inductively powered CPoW module, which operates wirelessly by using the current flowing through a typical distribution conductor as its power source and a wireless data link for communication, has been configured to measure instantaneous line current at high frequency (nominally 3,000 samples per second) with 12-bit resolution. The design process for this module is detailed in this study, including background research, individual block design and testing, printed circuit board (PCB) design, and final characterization of the system. To validate the performance of this module, tests of power requirements, measurement accuracy, battery life, susceptibility to electromagnetic interference, and fault detection performance were performed. The results indicate that the design under investigation will satisfy the technical and physical constraints required for bulk deployment in an actual distribution network after manufacturing optimizations. After the test results were summarized, the future research and development activities needed to finalize this design for commercial deployment were identified and discussed.
ContributorsPatterson, John (Author) / Pal, Anamitra (Thesis advisor) / Ogras, Umit (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2021
161658-Thumbnail Image.png
Description
Nowadays, the widespread use of distributed generators (DGs) raises significant challenges for the design, planning, and operation of power systems. To avoid the harm caused by excessive DGs, evaluating the reliability and sustainability of the system with high penetration of DGs is essential. The concept of hosting capacity (HC) is

Nowadays, the widespread use of distributed generators (DGs) raises significant challenges for the design, planning, and operation of power systems. To avoid the harm caused by excessive DGs, evaluating the reliability and sustainability of the system with high penetration of DGs is essential. The concept of hosting capacity (HC) is used to achieve this purpose. It is to assess the capability of a distribution grid to accommodate DGs without causing damage or updating facilities. To obtain the HC value, traditional HC analysis methods face many problems, including the computational difficulties caused by the large-scale simulations and calculations, lacking the considering temporal correlation from data to data, and the inefficient on real-time analysis. This paper proposes a machine learning-based method, the Spatial-Temporal Long Short-Term Memory (ST-LSTM), to overcome these drawbacks using the traditional HC analysis method. This method will significantly reduce the requirement of calculations and simulations, and obtain HC results in real-time. Using the time-series load profiles and the longest path method, ST-LSTMs can capture the temporal information and spatial information respectively. Moreover, compared with the basic Long Short-Term Memory (LSTM) model, this modified model will improve the performance in the HC analysis by some specific designs, which are the sensitivity gate to consider voltage sensitivity information, the dual forget gates to build spatial and temporal correlation.
ContributorsWu, Jiaqi (Author) / Weng, Yang (Thesis advisor) / Ayyanar, Raja (Committee member) / Cook, Elizabeth (Committee member) / Arizona State University (Publisher)
Created2021
153884-Thumbnail Image.png
Description
This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for

This research primarily deals with the design and validation of the protection system for a large scale meshed distribution system. The large scale system simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms, to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. The addition of distributed generation and power electronic based solid state transformer adds to the complexity of the protection. The FREEDM loop system has a fault current limiter and in addition, the Solid State Transformer (SST) limits the fault current at 2.0 per unit. Former students at ASU have developed the protection scheme using fiber-optic cable. However, during the NSF-FREEDM site visit, the National Science Foundation (NSF) team regarded the system incompatible for the long distances. Hence, a new protection scheme with a wireless scheme is presented in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The trip signal generated by the pilot protection system is used to trigger the FID (fault isolation device) which is an electronic circuit breaker operation (switched off/opening the FIDs). The trip signal must be received and accepted by the SST, and it must block the SST operation immediately. A comprehensive protection system for the large scale meshed distribution system has been developed in PSCAD with the ability to quickly detect the faults. The validation of the protection system is performed by building a hardware model using commercial relays at the ASU power laboratory.
ContributorsSharma, Nitish (Author) / Karady, George G. (Thesis advisor) / Holbert, Keith E. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2015
153925-Thumbnail Image.png
Description
This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these

This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast pro-tection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs.

Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this re-flects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a conventional system. The payback periods observed support the concept of introducing the FREEDM system.
ContributorsRaman, Apurva (Author) / Heydt, Gerald (Thesis advisor) / Karady, George G. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2015
153072-Thumbnail Image.png
Description
The development of new policies favoring integration of renewable energy into the grid has created a need to relook at our existing infrastructure resources and at the way the power system is currently operated. Also, the needs of electric energy markets and transmission/generation expansion planning has created a niche for

The development of new policies favoring integration of renewable energy into the grid has created a need to relook at our existing infrastructure resources and at the way the power system is currently operated. Also, the needs of electric energy markets and transmission/generation expansion planning has created a niche for development of new computationally efficient and yet reliable, simple and robust power flow tools for such studies. The so called dc power flow algorithm is an important power flow tool currently in use. However, the accuracy and performance of dc power flow results is highly variable due to the various formulations which are in use. This has thus intensified the interest of researchers in coming up with better equivalent dc models that can closely match the performance of ac power flow solution.

This thesis involves the development of novel hot start dc model using a power transfer distribution factors (PTDFs) approach. This document also discusses the problems of ill-conditioning / rank deficiency encountered while deriving this model. This model is then compared to several dc power flow models using the IEEE 118-bus system and ERCOT interconnection both as the base case ac solution and during single-line outage contingency analysis. The proposed model matches the base case ac solution better than contemporary dc power flow models used in the industry.
ContributorsSood, Puneet (Author) / Tylavsky, Daniel J (Thesis advisor) / Vittal, Vijay (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2014