Matching Items (102)
Filtering by

Clear all filters

190924-Thumbnail Image.png
Description
Ethylene is one of the most widely used organic compounds worldwide with ever increasing demand. Almost all the industries currently producing ethylene globally use the method of steam cracking, which, though highly selective and cost effective, is energy intensive along with having a high carbon footprint. This study aims to

Ethylene is one of the most widely used organic compounds worldwide with ever increasing demand. Almost all the industries currently producing ethylene globally use the method of steam cracking, which, though highly selective and cost effective, is energy intensive along with having a high carbon footprint. This study aims to analyze micro-scale partial oxidation of propane as a novel approach towards ethylene generation which is simpler, less energy consuming, operates at lower temperatures and causes minimum CO2 emission. The experimental study endeavors to maximize the ethylene production by investigating the effect of variables such as temperature, flow rate, equivalence ratio and reactor diameter. The micro-scale partial oxidation of propane is studied inside quartz tube reactors of 1 mm and 3 mm diameter at a temperature range of 800 to 900 oC, at varying flow rates of 10 to 100 sccm and equivalence ratios of 1 to 6. The study reveals ethylene yield has a strong dependence on all the above factors. However, the factors are not completely independent of each other. Adjusting certain factors and levels results in greater ethylene yields as high as 10%, but propane to ethylene conversion efficiency is approximately constant for most conditions. Low CO2 concentrations are also recorded for most of the factor and level combinations, indicating the potential to achieve lower CO2 yields compared to conventional approaches. The investigation indicates promise for application in the field of ethylene generation.
ContributorsMAHALKAR, PAWAN MUKUND (Author) / Milcarek, Ryan (Thesis advisor) / Kwon, Beomjin (Committee member) / Phelan, Patrick (Committee member) / Arizona State University (Publisher)
Created2023
172014-Thumbnail Image.png
Description
A well-insulated dark conventional rooftop can be hotter than any other urban surface, including pavements. Since rooftops cover around 20 – 25% of most urban areas, their role in the urban heat island effect is significant. In general, buildings exchange heat with the surroundings in three ways: heat release from

A well-insulated dark conventional rooftop can be hotter than any other urban surface, including pavements. Since rooftops cover around 20 – 25% of most urban areas, their role in the urban heat island effect is significant. In general, buildings exchange heat with the surroundings in three ways: heat release from the cooling/heating system, air exchange associated with exfiltration and relief air, and heat transfer between the building envelope and surroundings. Several recent studies show that the building envelope generates more heat release into the environment than any other building component.Current advancements in material science have enabled the development of materials and coatings with very high solar reflectance and thermal emissivity, and that can alter their radiative properties based on surface temperature. This dissertation is an effort to quantify the impact of recent developments in such technologies on urban air. The current study addresses three specific unresolved topics: 1) the relative importance of rooftop solar reflectance and thermal emissivity, 2) the role of rooftop radiative properties in different climates, and 3) the impact of temperature-adaptive exterior materials/coatings on building energy savings and urban cooling. The findings from this study show that the use of rooftop materials with solar reflectance above 0.9 maintain the surface temperature below ambient air temperature most of the time, even when the materials have conventional thermal emissivity (0.9). This research has demonstrated that for hot cities, rooftops with high solar reflectance and thermal emittance maximize building energy savings and always cool the surrounding air. For moderate climate regions, high solar reflectance and low thermal emittance result in the greatest building energy cost savings. This combination of radiative properties cools the air during the daytime and warms it at night. Finally, this research found that temperature-adaptive materials could play a significant role in reducing utility costs for poorly insulated buildings, but that they heat the surrounding air in the winter, irrespective of the rooftop insulation. Through the detailed analysis of building façade radiative properties, this dissertation offers climate-specific design guidance that can be used to simultaneously optimize energy costs while minimizing adverse warming of the surrounding environment.
ContributorsPrem Anand Jayaprabha, Jyothis Anand (Author) / Sailor, David (Thesis advisor) / Phelan, Patrick (Thesis advisor) / Huang, Huei-Ping (Committee member) / Wang, Liping (Committee member) / Yeom, Dongwoo Jason (Committee member) / Arizona State University (Publisher)
Created2022