Matching Items (107)
Filtering by

Clear all filters

150872-Thumbnail Image.png
Description
John Harbison is one of the most prominent composers of the twentieth and twenty-first centuries. He has made major contributions in all areas of classical music, including operas, symphonies, chamber music, choral works, and vocal pieces.Among his vast output is 'Four Songs of Solitude,' his only composition (to date) for

John Harbison is one of the most prominent composers of the twentieth and twenty-first centuries. He has made major contributions in all areas of classical music, including operas, symphonies, chamber music, choral works, and vocal pieces.Among his vast output is 'Four Songs of Solitude,' his only composition (to date) for solo violin. Though the piece is beautiful and reflective in nature, its inherent technical and musical difficulties present challenges to violinists preparing the piece. There is no published edition of 'Four Songs of Solitude' that includes bowings and fingerings, and violinists used to practicing and performing the études and repertoire of the eighteenth and nineteenth centuries may have difficulty determining how to successfully navigate the music. This paper examines the piece in detail, providing an analytic description of the music and suggestions for practice. An interview with the composer yielded many insights into the structural and harmonic events of the songs, and the composer's interpretive suggestions are given alongside technical suggestions by the author. The solo violin has a centuries-long legacy, and some of the most performed repertoire exists in the medium. 'Four Songs of Solitude' is a demanding set of pieces that stands out in late twentieth-century violin music. Providing information about the piece directly from the composer and suggestions for practice and performance increases the accessibility of the work for violinists seeking to bring it to the concert stage.
ContributorsSchreffler, Sarah (Author) / McLin, Katherine (Thesis advisor) / Hill, Gary (Committee member) / Holbrook, Amy (Committee member) / Spring, Robert (Committee member) / Swartz, Jonathan (Committee member) / Arizona State University (Publisher)
Created2012
153997-Thumbnail Image.png
Description
Detection of molecular interactions is critical for understanding many biological processes, for detecting disease biomarkers, and for screening drug candidates. Fluorescence-based approach can be problematic, especially when applied to the detection of small molecules. Various label-free techniques, such as surface plasmon resonance technique are sensitive to mass, making it extremely

Detection of molecular interactions is critical for understanding many biological processes, for detecting disease biomarkers, and for screening drug candidates. Fluorescence-based approach can be problematic, especially when applied to the detection of small molecules. Various label-free techniques, such as surface plasmon resonance technique are sensitive to mass, making it extremely challenging to detect small molecules. In this thesis, novel detection methods for molecular interactions are described.

First, a simple detection paradigm based on reflectance interferometry is developed. This method is simple, low cost and can be easily applied for protein array detection.

Second, a label-free charge sensitive optical detection (CSOD) technique is developed for detecting of both large and small molecules. The technique is based on that most molecules relevant to biomedical research and applications are charged or partially charged. An optical fiber is dipped into the well of a microplate. It detects the surface charge of the fiber, which does not decrease with the size (mass) of the molecule, making it particularly attractive for studying small molecules.

Third, a method for mechanically amplification detection of molecular interactions (MADMI) is developed. It provides quantitative analysis of small molecules interaction with membrane proteins in intact cells. The interactions are monitored by detecting a mechanical deformation in the membrane induced by the molecular interactions. With this novel method small molecules and membrane proteins interaction in the intact cells can be detected. This new paradigm provides mechanical amplification of small interaction signals, allowing us to measure the binding kinetics of both large and small molecules with membrane proteins, and to analyze heterogeneous nature of the binding kinetics between different cells, and different regions of a single cell.

Last, by tracking the cell membrane edge deformation, binding caused downstream event – granule secretory has been measured. This method focuses on the plasma membrane change when granules fuse with the cell. The fusion of granules increases the plasma membrane area and thus the cell edge expands. The expansion is localized at the vesicle release location. Granule size was calculated based on measured edge expansion. The membrane deformation due to the granule release is real-time monitored by this method.
ContributorsGuan, Yan (Author) / Tao, Nongjian (Thesis advisor) / LaBaer, Joshua (Committee member) / Goryll, Michael (Committee member) / Wang, Shaopeng (Committee member) / Arizona State University (Publisher)
Created2015
154000-Thumbnail Image.png
Description
In mesoscopic physics, conductance fluctuations are a quantum interference phenomenon that comes from the phase interference of electron wave functions scattered by the impurity disorder. During the past few decades, conductance fluctuations have been studied in various materials including metals, semiconductors and graphene. Since the patterns of conductance fluctuations is

In mesoscopic physics, conductance fluctuations are a quantum interference phenomenon that comes from the phase interference of electron wave functions scattered by the impurity disorder. During the past few decades, conductance fluctuations have been studied in various materials including metals, semiconductors and graphene. Since the patterns of conductance fluctuations is related to the distributions and configurations of the impurity scatterers, each sample has its unique pattern of fluctuations, which is considered as a sample fingerprint. Thus, research on conductance fluctuations attracts attention worldwide for its importance in both fundamental physics and potential technical applications. Since early experimental measurements of conductance fluctuations showed that the amplitudes of the fluctuations are on order of a universal value (e2/h), theorists proposed the hypothesis of ergodicity, e.g. the amplitudes of the conductance fluctuations by varying impurity configurations is the same as that from varying the Fermi energy or varying the magnetic field. They also proposed the principle of universality; e.g., that the observed fluctuations would appear the same in all materials. Recently, transport experiments in graphene reveal a deviation of fluctuation amplitudes from those expected from ergodicity.

Thus, in my thesis work, I have carried out numerical research on the conductance fluctuations in GaAs nanowires and graphene nanoribbons in order to examine whether or not the theoretical principles of universality and ergodicity hold. Finite difference methods are employed to study the conductance fluctuations in GaAs nanowires, but an atomic basis tight-binding model is used in calculations of graphene nanoribbons. Both short-range disorder and long-range disorder are considered in the simulations of graphene. A stabilized recursive scattering matrix technique is used to calculate the conductance. In particular, the dependence of the observed fluctuations on the amplitude of the disorder has been investigated. Finally, the root-mean-square values of the amplitude of conductance fluctuations are calculated as a basis with which to draw the appropriate conclusions. The results for Fermi energy sweeps and magnetic field sweeps are compared and effects of magnetic fields on the conductance fluctuations of Fermi energy sweeps are discussed for both GaAs nanowires and graphene nanoribbons.
ContributorsLiu, Bobo (Author) / Ferry, David K. (Thesis advisor) / Akis, Richard (Committee member) / Saraniti, Marco (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2015
154131-Thumbnail Image.png
Description
Solid-state nanopore research, used in the field of biomolecule detection and separation, has developed rapidly during the last decade. An electric field generated from the nanopore membrane to the aperture surface by a bias voltage can be used to electrostatically control the transport of charges. This results in ionic current

Solid-state nanopore research, used in the field of biomolecule detection and separation, has developed rapidly during the last decade. An electric field generated from the nanopore membrane to the aperture surface by a bias voltage can be used to electrostatically control the transport of charges. This results in ionic current rectification that can be used for applications such as biomolecule filtration and DNA sequencing.

In this doctoral research, a voltage bias was applied on the device silicon layer of Silicon-on-Insulator (SOI) cylindrical single nanopore to analyze how the perpendicular gate electrical field affected the ionic current through the pore. The nanopore was fabricated using electron beam lithography (EBL) and reactive ion etching (RIE) which are standard CMOS processes and can be integrated into any electronic circuit with massive production. The long cylindrical pore shape provides a larger surface area inside the aperture compared to other nanopores whose surface charge is of vital importance to ion transport.

Ionic transport through the nanopore was characterized by measuring the ionic conductance of the nanopore in aqueous hydrochloric acid and potassium chloride solutions under field effect modulation. The nanopores were separately coated with negatively charged thermal silicon oxide and positively charged aluminum oxide using Atomic Layer Deposition. Both layers worked as electrical insulation layers preventing leakage current once the substrate bias was applied. Different surface charges also provided different counterion-coion configurations. The transverse conductance of the nanopore at low electrolyte concentrations (<10-4 M) changed with voltage bias when the Debye length was comparable to the dimensions of the nanopore.

Ionic transport through nanopores coated with polyelectrolyte (PE) brushes were also investigated in ionic solutions with various pH values using Electrochemical Impedance spectroscopy (EIS). The pH sensitive poly[2–(dimethylamino) ethyl methacrylate] (PDMAEMA) PE brushes were integrated on the inner walls as well as the surface of the thermal oxidized SOI cylindrical nanopore using surface-initiated atom transfer radical polymerization (SI-ATRP). An equivalent circuit model was developed to extract conductive and resistive values of the nanopore in ionic solutions. The ionic conductance of PE coated nanopore was effectively rectified by varying the pH and gate bias.
ContributorsWang, Xiaofeng (Author) / Goryll, Michael (Thesis advisor) / Thornton, Trevor J (Committee member) / Christen, Jennifer M (Committee member) / Yu, Hongbin (Committee member) / Arizona State University (Publisher)
Created2015
154014-Thumbnail Image.png
Description
Biosensors aiming at detection of target analytes, such as proteins, microbes, virus, and toxins, are widely needed for various applications including detection of chemical and biological warfare (CBW) agents, biomedicine, environmental monitoring, and drug screening. Surface Plasmon Resonance (SPR), as a surface-sensitive analytical tool, can very sensitively respond to minute

Biosensors aiming at detection of target analytes, such as proteins, microbes, virus, and toxins, are widely needed for various applications including detection of chemical and biological warfare (CBW) agents, biomedicine, environmental monitoring, and drug screening. Surface Plasmon Resonance (SPR), as a surface-sensitive analytical tool, can very sensitively respond to minute changes of refractive index occurring adjacent to a metal film, offering detection limits up to a few ppt (pg/mL). Through SPR, the process of protein adsorption may be monitored in real-time, and transduced into an SPR angle shift. This unique technique bypasses the time-consuming, labor-intensive labeling processes, such as radioisotope and fluorescence labeling. More importantly, the method avoids the modification of the biomarker’s characteristics and behaviors by labeling that often occurs in traditional biosensors. While many transducers, including SPR, offer high sensitivity, selectivity is determined by the bio-receptors. In traditional biosensors, the selectivity is provided by bio-receptors possessing highly specific binding affinity to capture target analytes, yet their use in biosensors are often limited by their relatively-weak binding affinity with analyte, non-specific adsorption, need for optimization conditions, low reproducibility, and difficulties integrating onto the surface of transducers. In order to circumvent the use of bio-receptors, the competitive adsorption of proteins, termed the Vroman effect, is utilized in this work. The Vroman effect was first reported by Vroman and Adams in 1969. The competitive adsorption targeted here occurs among different proteins competing to adsorb to a surface, when more than one type of protein is present. When lower-affinity proteins are adsorbed on the surface first, they can be displaced by higher-affinity proteins arriving at the surface at a later point in time. Moreover, only low-affinity proteins can be displaced by high-affinity proteins, typically possessing higher molecular weight, yet the reverse sequence does not occur. The SPR biosensor based on competitive adsorption is successfully demonstrated to detect fibrinogen and thyroglobulin (Tg) in undiluted human serum and copper ions in drinking water through the denatured albumin.
ContributorsWang, Ran (Author) / Chae, Junseok (Thesis advisor) / Bakkaloglu, Bertan (Committee member) / Tsow, Tsing (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2015
154015-Thumbnail Image.png
Description
The microelectronics technology has seen a tremendous growth over the past sixty years. The advancements in microelectronics, which shows the capability of yielding highly reliable and reproducible structures, have made the mass production of integrated electronic components feasible. Miniaturized, low-cost, and accurate sensors became available due to the rise of

The microelectronics technology has seen a tremendous growth over the past sixty years. The advancements in microelectronics, which shows the capability of yielding highly reliable and reproducible structures, have made the mass production of integrated electronic components feasible. Miniaturized, low-cost, and accurate sensors became available due to the rise of the microelectronics industry. A variety of sensors are being used extensively in many portable applications. These sensors are promising not only in research area but also in daily routine applications.

However, many sensing systems are relatively bulky, complicated, and expensive and main advantages of new sensors do not play an important role in practical applications. Many challenges arise due to intricacies for sensor packaging, especially operation in a solution environment. Additional problems emerge when interfacing sensors with external off-chip components. A large amount of research in the field of sensors has been focused on how to improve the system integration.

This work presents new methods for the design, fabrication, and integration of sensor systems. This thesis addresses these challenges, for example, interfacing microelectronic system to a liquid environment and developing a new technique for impedimetric measurement. This work also shows a new design for on-chip optical sensor without any other extra components or post-processing.
ContributorsLuo, Tao (Author) / Blain Christen, Jennifer (Thesis advisor) / Song, Hongjiang (Committee member) / Goryll, Michael (Committee member) / Yu, Hongbin (Committee member) / Arizona State University (Publisher)
Created2015
154176-Thumbnail Image.png
Description
Programmable metallization cell (PMC) technology employs the mechanisms of metal ion transport in solid electrolytes (SE) and electrochemical redox reactions in order to form metallic electrodeposits. When a positive bias is applied to an anode opposite to a cathode, atoms at the anode are oxidized to ions and dissolve into

Programmable metallization cell (PMC) technology employs the mechanisms of metal ion transport in solid electrolytes (SE) and electrochemical redox reactions in order to form metallic electrodeposits. When a positive bias is applied to an anode opposite to a cathode, atoms at the anode are oxidized to ions and dissolve into the SE. Under the influence of the electric field, the ions move to the cathode and become reduced to form the electrodeposits. These electrodeposits are filamentary in nature and persistent, and since they are metallic can alter the physical characteristics of the material on which they are formed. PMCs can be used as next generation memories, radio frequency (RF) switches and physical unclonable functions (PUFs).

The morphology of the filaments is impacted by the biasing conditions. Under a relatively high applied electric field, they form as dendritic elements with a low fractal dimension (FD), whereas a low electric field leads to high FD features. Ion depletion effects in the SE due to low ion diffusivity/mobility also influences the morphology by limiting the ion supply into the growing electrodeposit.

Ion transport in SE is due to hopping transitions driven by drift and diffusion force. A physical model of ion hopping with Brownian motion has been proposed, in which the ion transitions are random when time window is larger than characteristic time. The random growth process of filaments in PMC adds entropy to the electrodeposition, which leads to random features in the dendritic patterns. Such patterns has extremely high information capacity due to the fractal nature of the electrodeposits.

In this project, lateral-growth PMCs were fabricated, whose LRS resistance is less than 10Ω, which can be used as RF switches. Also, an array of radial-growth PMCs was fabricated, on which multiple dendrites, all with different shapes, could be grown simultaneously. Those patterns can be used as secure keys in PUFs and authentication can be performed by optical scanning.

A kinetic Monte Carlo (KMC) model is developed to simulate the ion transportation in SE under electric field. The simulation results matched experimental data well that validated the ion hopping model.
ContributorsYu, Weijie (Author) / Kozicki, Michael N (Thesis advisor) / Barnaby, Hugh (Thesis advisor) / Diaz, Rodolfo (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2015
153903-Thumbnail Image.png
Description
In the nano-regime many materials exhibit properties that are quite different from their bulk counterparts. These nano-properties have been shown to be useful in a wide range of applications with nanomaterials being used for catalysts, in energy production, as protective coatings, and in medical treatment. While there is no shortage

In the nano-regime many materials exhibit properties that are quite different from their bulk counterparts. These nano-properties have been shown to be useful in a wide range of applications with nanomaterials being used for catalysts, in energy production, as protective coatings, and in medical treatment. While there is no shortage of exciting and novel applications, the world of nanomaterials suffers from a lack of large scale manufacturing techniques. The current methods and equipment used for manufacturing nanomaterials are generally slow, expensive, potentially dangerous, and material specific. The research and widespread use of nanomaterials has undoubtedly been hindered by this lack of appropriate tooling. This work details the effort to create a novel nanomaterial synthesis and deposition platform capable of operating at industrial level rates and reliability.

The tool, referred to as Deppy, deposits material via hypersonic impaction, a two chamber process that takes advantage of compressible fluids operating in the choked flow regime to accelerate particles to up several thousand meters per second before they impact and stick to the substrate. This allows for the energetic separation of the synthesis and deposition processes while still behaving as a continuous flow reactor giving Deppy the unique ability to independently control the particle properties and the deposited film properties. While the ultimate goal is to design a tool capable of producing a broad range of nanomaterial films, this work will showcase Deppy's ability to produce silicon nano-particle films as a proof of concept.

By adjusting parameters in the upstream chamber the particle composition was varied from completely amorphous to highly crystalline as confirmed by Raman spectroscopy. By adjusting parameters in the downstream chamber significant variation of the film's density was achieved. Further it was shown that the system is capable of making these adjustments in each chamber without affecting the operation of the other.
ContributorsFirth, Peter (Author) / Holman, Zachary C (Thesis advisor) / Kozicki, Michael (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2015
155911-Thumbnail Image.png
Description
To be a versatile violinist, one needs interdependence of aural, visual and kinesthetic skills. This thesis introduces aural, visual and kinesthetic learning modalities, and explores the way each is used in the Suzuki, Paul Rolland, Orff, Kodály, and Dalcroze methods, as well as in Edwin Gordon’s Musical Learning Theory. Other

To be a versatile violinist, one needs interdependence of aural, visual and kinesthetic skills. This thesis introduces aural, visual and kinesthetic learning modalities, and explores the way each is used in the Suzuki, Paul Rolland, Orff, Kodály, and Dalcroze methods, as well as in Edwin Gordon’s Musical Learning Theory. Other methods and pedagogical approaches were consulted and influential in developing the curriculum, such as the teaching of Mimi Zweig, but were not included in this paper either because of an overlap with other methods or insufficient comparable material. This paper additionally presents a new curriculum for teaching beginning violin that incorporates aural, visual, and kinesthetic learning in a systematic and comprehensive manner. It also details a sequenced progression to learn new repertoire and develop proficiency with rhythm, solfège, reading and writing musical notation, and left- and right-hand technique.
ContributorsTang, Tee Tong (Author) / Swartz, Jonathan (Thesis advisor) / Schmidt, Margaret (Committee member) / Feisst, Sabine (Committee member) / Arizona State University (Publisher)
Created2017
155922-Thumbnail Image.png
Description
Total dose sensing systems (or radiation detection systems) have many applications,

ranging from survey monitors used to supervise the generated radioactive waste at

nuclear power plants to personal dosimeters which measure the radiation dose

accumulated in individuals. This dissertation work will present two different types of

novel devices developed at Arizona State University for

Total dose sensing systems (or radiation detection systems) have many applications,

ranging from survey monitors used to supervise the generated radioactive waste at

nuclear power plants to personal dosimeters which measure the radiation dose

accumulated in individuals. This dissertation work will present two different types of

novel devices developed at Arizona State University for total dose sensing applications.

The first detector technology is a mechanically flexible metal-chalcogenide glass (ChG)

based system which is fabricated on low cost substrates and are intended as disposable

total dose sensors. Compared to existing commercial technologies, these thin film

radiation sensors are simpler in form and function, and cheaper to produce and operate.

The sensors measure dose through resistance change and are suitable for applications

such as reactor dosimetry, radiation chemistry, and clinical dosimetry. They are ideal for

wearable devices due to the lightweight construction, inherent robustness to resist

breaking when mechanically stressed, and ability to attach to non-flat objects. Moreover,

their performance can be easily controlled by tuning design variables and changing

incorporated materials. The second detector technology is a wireless dosimeter intended

for remote total dose sensing. They are based on a capacitively loaded folded patch

antenna resonating in the range of 3 GHz to 8 GHz for which the load capacitance varies

as a function of total dose. The dosimeter does not need power to operate thus enabling

its use and implementation in the field without requiring a battery for its read-out. As a

result, the dosimeter is suitable for applications such as unattended detection systems

destined for covert monitoring of merchandise crossing borders, where nuclear material

tracking is a concern. The sensitive element can be any device exhibiting a known

variation of capacitance with total ionizing dose. The sensitivity of the dosimeter is

related to the capacitance variation of the radiation sensitive device as well as the high

frequency system used for reading. Both technologies come with the advantage that they

are easy to manufacture with reasonably low cost and sensing can be readily read-out.
ContributorsMahmud, Adnan, Ph.D (Author) / Barnaby, Hugh J. (Thesis advisor) / Kozicki, Michael N (Committee member) / Gonzalez-Velo, Yago (Committee member) / Goryll, Michael (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2017