150059-Thumbnail Image.png
Description
Dynamic loading is the term used for one way of optimally loading a transformer. Dynamic loading means the utility takes into account the thermal time constant of the transformer along with the cooling mode transitions, loading profile and ambient temperature when determining the time-varying loading capability of a transformer. Knowing

Dynamic loading is the term used for one way of optimally loading a transformer. Dynamic loading means the utility takes into account the thermal time constant of the transformer along with the cooling mode transitions, loading profile and ambient temperature when determining the time-varying loading capability of a transformer. Knowing the maximum dynamic loading rating can increase utilization of the transformer while not reducing life-expectancy, delaying the replacement of the transformer. This document presents the progress on the transformer dynamic loading project sponsored by Salt River Project (SRP). A software application which performs dynamic loading for substation distribution transformers with appropriate transformer thermal models is developed in this project. Two kinds of thermal hottest-spot temperature (HST) and top-oil temperature (TOT) models that will be used in the application--the ASU HST/TOT models and the ANSI models--are presented. Brief validations of the ASU models are presented, showing that the ASU models are accurate in simulating the thermal processes of the transformers. For this production grade application, both the ANSI and the ASU models are built and tested to select the most appropriate models to be used in the dynamic loading calculations. An existing application to build and select the TOT model was used as a starting point for the enhancements developed in this work. These enhancements include:  Adding the ability to develop HST models to the existing application,  Adding metrics to evaluate the models accuracy and selecting which model will be used in dynamic loading calculation  Adding the capability to perform dynamic loading calculations,  Production of a maximum dynamic load profile that the transformer can tolerate without acceleration of the insulation aging,  Provide suitable output (plots and text) for the results of the dynamic loading calculation. Other challenges discussed include: modification to the input data format, data-quality control, cooling mode estimation. Efforts to overcome these challenges are discussed in this work.
ContributorsLiu, Yi (Author) / Tylavksy, Daniel J (Thesis advisor) / Karady, George G. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2011
150020-Thumbnail Image.png
Description
Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would

Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would improve dietary self-monitoring over the traditional paper-and-pencil method. The study also looked at whether the difference in methods would affect weight loss. Forty-seven adults (BMI 25 to 40 kg/m2) completed an 8-week study focused on tracking the difference in adherence to a self-monitoring protocol and subsequent weight loss. Participants owning iPhones (n=17) used the 'Lose It' application (AP) for diet and exercise tracking and were compared to smartphone participants who recorded dietary intake using a memo (ME) feature (n=15) on their phone and participants using the traditional paper-and-pencil (PA) method (n=15). There was no significant difference in completion rates between groups with an overall completion rate of 85.5%. The overall mean adherence to self-monitoring for the 8-week period was better in the AP group than the PA group (p = .024). No significant difference was found between the AP group and ME group (p = .148), or the ME group and the PA group (p = .457). Weight loss for the 8 week study was significant for all groups (p = .028). There was no significant difference in weight loss between groups. Number of days recorded regardless of group assignment showed a weak correlation to weight loss success (p = .068). Smartphone owners seeking to lose weight should be encouraged by the potential success associated with dietary tracking using a smartphone app as opposed to the traditional paper-and-pencil method.
ContributorsCunningham, Barbara (Author) / Wharton, Christopher (Christopher Mack), 1977- (Thesis advisor) / Johnston, Carol (Committee member) / Hall, Richard (Committee member) / Arizona State University (Publisher)
Created2012
149997-Thumbnail Image.png
Description
This thesis pursues a method to deregulate the electric distribution system and provide support to distributed renewable generation. A locational marginal price is used to determine prices across a distribution network in real-time. The real-time pricing may provide benefits such as a reduced electricity bill, decreased peak demand, and lower

This thesis pursues a method to deregulate the electric distribution system and provide support to distributed renewable generation. A locational marginal price is used to determine prices across a distribution network in real-time. The real-time pricing may provide benefits such as a reduced electricity bill, decreased peak demand, and lower emissions. This distribution locational marginal price (D-LMP) determines the cost of electricity at each node in the electrical network. The D-LMP is comprised of the cost of energy, cost of losses, and a renewable energy premium. The renewable premium is an adjustable function to compensate `green' distributed generation. A D-LMP is derived and formulated from the PJM model, as well as several alternative formulations. The logistics and infrastructure an implementation is briefly discussed. This study also takes advantage of the D-LMP real-time pricing to implement distributed storage technology. A storage schedule optimization is developed using linear programming. Day-ahead LMPs and historical load data are used to determine a predictive optimization. A test bed is created to represent a practical electric distribution system. Historical load, solar, and LMP data are used in the test bed to create a realistic environment. A power flow and tabulation of the D-LMPs was conducted for twelve test cases. The test cases included various penetrations of solar photovoltaics (PV), system networking, and the inclusion of storage technology. Tables of the D-LMPs and network voltages are presented in this work. The final costs are summed and the basic economics are examined. The use of a D-LMP can lower costs across a system when advanced technologies are used. Storage improves system costs, decreases losses, improves system load factor, and bolsters voltage. Solar energy provides many of these same attributes at lower penetrations, but high penetrations have a detrimental effect on the system. System networking also increases these positive effects. The D-LMP has a positive impact on residential customer cost, while greatly increasing the costs for the industrial sector. The D-LMP appears to have many positive impacts on the distribution system but proper cost allocation needs further development.
ContributorsKiefer, Brian Daniel (Author) / Heydt, Gerald T (Thesis advisor) / Shunk, Dan (Committee member) / Hedman, Kory (Committee member) / Arizona State University (Publisher)
Created2011
150050-Thumbnail Image.png
Description
The development of a Solid State Transformer (SST) that incorporates a DC-DC multiport converter to integrate both photovoltaic (PV) power generation and battery energy storage is presented in this dissertation. The DC-DC stage is based on a quad-active-bridge (QAB) converter which not only provides isolation for the load, but also

The development of a Solid State Transformer (SST) that incorporates a DC-DC multiport converter to integrate both photovoltaic (PV) power generation and battery energy storage is presented in this dissertation. The DC-DC stage is based on a quad-active-bridge (QAB) converter which not only provides isolation for the load, but also for the PV and storage. The AC-DC stage is implemented with a pulse-width-modulated (PWM) single phase rectifier. A unified gyrator-based average model is developed for a general multi-active-bridge (MAB) converter controlled through phase-shift modulation (PSM). Expressions to determine the power rating of the MAB ports are also derived. The developed gyrator-based average model is applied to the QAB converter for faster simulations of the proposed SST during the control design process as well for deriving the state-space representation of the plant. Both linear quadratic regulator (LQR) and single-input-single-output (SISO) types of controllers are designed for the DC-DC stage. A novel technique that complements the SISO controller by taking into account the cross-coupling characteristics of the QAB converter is also presented herein. Cascaded SISO controllers are designed for the AC-DC stage. The QAB demanded power is calculated at the QAB controls and then fed into the rectifier controls in order to minimize the effect of the interaction between the two SST stages. The dynamic performance of the designed control loops based on the proposed control strategies are verified through extensive simulation of the SST average and switching models. The experimental results presented herein show that the transient responses for each control strategy match those from the simulations results thus validating them.
ContributorsFalcones, Sixifo Daniel (Author) / Ayyanar, Raja (Thesis advisor) / Karady, George G. (Committee member) / Tylavsky, Daniel (Committee member) / Tsakalis, Konstantinos (Committee member) / Arizona State University (Publisher)
Created2011
149777-Thumbnail Image.png
Description
Nut consumption, specifically almonds, have been shown to help maintain weight and influence disease risk factors in adult populations. Limited studies have been conducted examining the effect of a small dose of almonds on energy intake and body weight. The objective of this study was to determine the influence of

Nut consumption, specifically almonds, have been shown to help maintain weight and influence disease risk factors in adult populations. Limited studies have been conducted examining the effect of a small dose of almonds on energy intake and body weight. The objective of this study was to determine the influence of pre-meal almond consumption on energy intake and weight in overweight and obese adults. In this study included 21, overweight or obese, participants who were considered healthy or had a controlled disease state. This 8-week parallel arm study, participants were randomized to consume an isocaloric amount of almonds, (1 oz) serving, or two (2 oz) cheese stick serving, 30 minutes before the dinner meal, 5 times per week. Anthropometric measurements including weight, waist circumference, and body fat percentage were recorded at baseline, week 1, 4, and 8. Measurement of energy intake was self-reported for two consecutive days at week 1, 4 and 8 using the ASA24 automated dietary program. The energy intake after 8 weeks of almond consumption was not significantly different when compared to the control group (p=0.965). In addition, body weight was not significantly reduced after 8 weeks of the almond intervention (p=0.562). Other parameters measured in this 8-week trial did not differ between the intervention and the control group. These data presented are underpowered and therefore inconclusive on the effects that 1 oz of almonds, in the diet, 5 per week has on energy intake and bodyweight.
ContributorsMcBride, Lindsey (Author) / Johnston, Carol (Thesis advisor) / Swan, Pamela (Committee member) / Mayol-Kreiser, Sandra (Committee member) / Arizona State University (Publisher)
Created2011
149767-Thumbnail Image.png
Description
ABSTRACT Epidemiological studies have suggested a link between nut consumption and weight. The possible effects of regular nut consumption as a method of weight loss has shown minimal results with 2-3 servings of nut products per day. This 8 week study sought to investigate the effect of more modest nut

ABSTRACT Epidemiological studies have suggested a link between nut consumption and weight. The possible effects of regular nut consumption as a method of weight loss has shown minimal results with 2-3 servings of nut products per day. This 8 week study sought to investigate the effect of more modest nut consumption (1 oz./day, 5 days/week) on dietary compensation in healthy overweight individuals. Overweight and obese participants (n = 28) were recruited from the local community and were randomly assigned to either almond (NUT) or control (CON) group in this randomized, parallel-arm study. Subjects were instructed to eat their respective foods 30 minutes before the dinner meal. 24 hour diet recalls were completed pre-trial and at study weeks 1, 4 and 8. Self-reported satiety data were completed at study weeks 1, 4, and 8. Attrition was unexpectedly high, with 13 participants completing 24 dietary recall data through study week 8. High attrition limited statistical analyses. Results suggested a lack of effect for time or interaction for satiety data (within groups p = 0.997, between groups p = 0.367). Homogeneity of of inter-correlations could not be tested for 24-hour recall data as there were fewer than 2 nonsingular cell covariance matrices. In conclusion, this study was unable to prove or disprove the effectiveness of almonds to induce dietary compensation.
ContributorsJahns, Marshall (Author) / Johnston, Carol (Thesis advisor) / Hall, Richard (Committee member) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Arizona State University (Publisher)
Created2011
150415-Thumbnail Image.png
Description
ABSTRACT This study evaluated the LoseIt Smart Phone app by Fit Now Inc. for nutritional quality among users during an 8 week behavioral modification weight loss protocol. All participants owned smart phones and were cluster randomized to either a control group using paper and pencil record keeping, a memo grou

ABSTRACT This study evaluated the LoseIt Smart Phone app by Fit Now Inc. for nutritional quality among users during an 8 week behavioral modification weight loss protocol. All participants owned smart phones and were cluster randomized to either a control group using paper and pencil record keeping, a memo group using a memo function on their smart phones, or the LoseIt app group which was composed of the participants who owned iPhones. Thirty one participants completed the study protocol: 10 participants from the LoseIt app group, 10 participants from the memo group, and 11 participants from the paper and pencil group. Food records were analyzed using Food Processor by ESHA and the nutritional quality was scored using the Healthy Eating Index - 2005 (HEI-2005). Scores were compared using One-Way ANOVA with no significant changes in any category across all groups. Non-parametric statistics were then used to determine changes between combined memo and paper and pencil groups and the LoseIt app group as the memo and paper and pencil group received live counseling at biweekly intervals and the LoseIt group did not. No significant difference was found in HEI scores across all categories, however a trend was noted for total HEI score with higher scores among the memo and paper and pencil group participants p=0.091. Conclusion, no significant difference was detected between users of the smart phone app LoseIt and memo and paper and pencil groups. More research is needed to determine the impact of in-person counseling versus user feedback provided with the LoseIt smart phone app.
ContributorsCowan, David Kevin (Author) / Johnston, Carol (Thesis advisor) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Mayol-Kreiser, Sandra (Committee member) / Arizona State University (Publisher)
Created2011
149932-Thumbnail Image.png
Description
Recent changes in the energy markets structure combined with the conti-nuous load growth have caused power systems to be operated under more stressed conditions. In addition, the nature of power systems has also grown more complex and dynamic because of the increasing use of long inter-area tie-lines and the high

Recent changes in the energy markets structure combined with the conti-nuous load growth have caused power systems to be operated under more stressed conditions. In addition, the nature of power systems has also grown more complex and dynamic because of the increasing use of long inter-area tie-lines and the high motor loads especially those comprised mainly of residential single phase A/C motors. Therefore, delayed voltage recovery, fast voltage collapse and short term voltage stability issues in general have obtained significant importance in relia-bility studies. Shunt VAr injection has been used as a countermeasure for voltage instability. However, the dynamic and fast nature of short term voltage instability requires fast and sufficient VAr injection, and therefore dynamic VAr devices such as Static VAr Compensators (SVCs) and STATic COMpensators (STAT-COMs) are used. The location and size of such devices are optimized in order to improve their efficiency and reduce initial costs. In this work time domain dy-namic analysis was used to evaluate trajectory voltage sensitivities for each time step. Linear programming was then performed to determine the optimal amount of required VAr injection at each bus, using voltage sensitivities as weighting factors. Optimal VAr injection values from different operating conditions were weighted and averaged in order to obtain a final setting of the VAr requirement. Some buses under consideration were either assigned very small VAr injection values, or not assigned any value at all. Therefore, the approach used in this work was found to be useful in not only determining the optimal size of SVCs, but also their location.
ContributorsSalloum, Ahmed (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2011
149658-Thumbnail Image.png
Description
Hydropower generation is one of the clean renewable energies which has received great attention in the power industry. Hydropower has been the leading source of renewable energy. It provides more than 86% of all electricity generated by renewable sources worldwide. Generally, the life span of a hydropower plant is considered

Hydropower generation is one of the clean renewable energies which has received great attention in the power industry. Hydropower has been the leading source of renewable energy. It provides more than 86% of all electricity generated by renewable sources worldwide. Generally, the life span of a hydropower plant is considered as 30 to 50 years. Power plants over 30 years old usually conduct a feasibility study of rehabilitation on their entire facilities including infrastructure. By age 35, the forced outage rate increases by 10 percentage points compared to the previous year. Much longer outages occur in power plants older than 20 years. Consequently, the forced outage rate increases exponentially due to these longer outages. Although these long forced outages are not frequent, their impact is immense. If reasonable timing of rehabilitation is missed, an abrupt long-term outage could occur and additional unnecessary repairs and inefficiencies would follow. On the contrary, too early replacement might cause the waste of revenue. The hydropower plants of Korea Water Resources Corporation (hereafter K-water) are utilized for this study. Twenty-four K-water generators comprise the population for quantifying the reliability of each equipment. A facility in a hydropower plant is a repairable system because most failures can be fixed without replacing the entire facility. The fault data of each power plant are collected, within which only forced outage faults are considered as raw data for reliability analyses. The mean cumulative repair functions (MCF) of each facility are determined with the failure data tables, using Nelson's graph method. The power law model, a popular model for a repairable system, can also be obtained to represent representative equipment and system availability. The criterion-based analysis of HydroAmp is used to provide more accurate reliability of each power plant. Two case studies are presented to enhance the understanding of the availability of each power plant and represent economic evaluations for modernization. Also, equipment in a hydropower plant is categorized into two groups based on their reliability for determining modernization timing and their suitable replacement periods are obtained using simulation.
ContributorsKwon, Ogeuk (Author) / Holbert, Keith E. (Thesis advisor) / Heydt, Gerald T (Committee member) / Pan, Rong (Committee member) / Arizona State University (Publisher)
Created2011
150199-Thumbnail Image.png
Description
Vitamin C is a micronutrient with many important physiological roles. It can function as a reducing agent, a free radical scavenger, and an enzyme cofactor. Much research has examined the potential of vitamin C supplements to enhance exercise capacity in trained athletes; however, little is known regarding the effects of

Vitamin C is a micronutrient with many important physiological roles. It can function as a reducing agent, a free radical scavenger, and an enzyme cofactor. Much research has examined the potential of vitamin C supplements to enhance exercise capacity in trained athletes; however, little is known regarding the effects of vitamin C supplements on the promotion of leisure-time physical activity in the general population. This area deserves attention since 1/3 of Americans have below adequate vitamin C status, and since aversion to exercise, fatigue, and altered mood states are the earliest signs of poor vitamin C status. This study analyzed the effect of supplementing 500 mg twice daily of vitamin C on self-reported leisure-time activity levels and mood states in young men. Twenty-nine healthy, young men, aged 18-35 years, were stratified by age, BMI, smoking status, and plasma vitamin C concentrations and assigned to either a control (CON) or experimental group (VTC) for the 8-week randomized, double-blinded, parallel arm trial. Subjects were instructed to keep track of their leisure-time physical activity by filling out the validated Godin Leisure-Time Exercise Questionnaire weekly for the entire study. In addition, subjects took the self-administered Profile of Mood States (POMS) at baseline, week 4, and week 8 to observe mood states. Plasma vitamin C concentrations were analyzed at the initial screening, week 4, and week 8 of the study. Plasma vitamin C concentrations significantly differed by group at week 4 and week 8. Furthermore, vitamin C supplementation significantly increased self-reported mild, moderate, and strenuous activity levels during the 8-week trial. Overall, total physical activity scores increased nearly 50% in the VTC group as compared to 18% in the CON group (p=0.001). However, mood states were not significantly impacted by vitamin C supplementation during the trial. This study provides the first experimental evidence that supplementing 500 mg of vitamin C twice daily can be effective in increasing leisure-time physical activity in healthy young men. This study, however, was unable to link improvements in physical activity rates to improved mood states. Since sedentary behaviors have been implicated in the rise of obesity in the U.S., further research should be conducted to substantiate the finding that vitamin C supplementation increases physical activity.
ContributorsSchumacher, Sarah (Author) / Johnston, Carol (Thesis advisor) / Appel, Christy (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2012