The large distributed electric power system is a hierarchical network involving the

transportation of power from the sources of power generation via an intermediate

densely connected transmission network to a large distribution network of end-users

at the lowest level of the hierarchy. At each level of the hierarchy (generation/ trans-

mission/ distribution), the system

The large distributed electric power system is a hierarchical network involving the

transportation of power from the sources of power generation via an intermediate

densely connected transmission network to a large distribution network of end-users

at the lowest level of the hierarchy. At each level of the hierarchy (generation/ trans-

mission/ distribution), the system is managed and monitored with a combination of

(a) supervisory control and data acquisition (SCADA); and (b) energy management

systems (EMSs) that process the collected data and make control and actuation de-

cisions using the collected data. However, at all levels of the hierarchy, both SCADA

and EMSs are vulnerable to cyber attacks. Furthermore, given the criticality of the

electric power infrastructure, cyber attacks can have severe economic and social con-

sequences.

This thesis focuses on cyber attacks on SCADA and EMS at the transmission

level of the electric power system. The goal is to study the consequences of three

classes of cyber attacks that can change topology data. These classes include: (i)

unobservable state-preserving cyber attacks that only change the topology data; (ii)

unobservable state-and-topology cyber-physical attacks that change both states and

topology data to enable a coordinated physical and cyber attack; and (iii) topology-

targeted man-in-the-middle (MitM) communication attacks that alter topology data

shared during inter-EMS communication. Specically, attack class (i) and (ii) focus on

the unobservable attacks on single regional EMS while class (iii) focuses on the MitM

attacks on communication links between regional EMSs. For each class of attacks,

the theoretical attack model and the implementation of attacks are provided, and the

worst-case attack and its consequences are exhaustively studied. In particularly, for

class (ii), a two-stage optimization problem is introduced to study worst-case attacks

that can cause a physical line over

ow that is unobservable in the cyber layer. The long-term implication and the system anomalies are demonstrated via simulation.

For attack classes (i) and (ii), both mathematical and experimental analyses sug-

gest that these unobservable attacks can be limited or even detected with resiliency

mechanisms including load monitoring, anomalous re-dispatches checking, and his-

torical data comparison. For attack class (iii), countermeasures including anomalous

tie-line interchange verication, anomalous re-dispatch alarms, and external contin-

gency lists sharing are needed to thwart such attacks.
ContributorsZhang, Jiazi (Author) / Sankar, Lalitha (Thesis advisor) / Hedman, Kory (Committee member) / Kosut, Oliver (Committee member) / Arizona State University (Publisher)
Created2015
156661-Thumbnail Image.png
Description
Multiple-input multiple-output systems have gained focus in the last decade due to the benefits they provide in enhancing the quality of communications. On the other hand, full-duplex communication has attracted remarkable attention due to its ability to improve the spectral efficiency compared to the existing half-duplex systems. Using full-duplex communications

Multiple-input multiple-output systems have gained focus in the last decade due to the benefits they provide in enhancing the quality of communications. On the other hand, full-duplex communication has attracted remarkable attention due to its ability to improve the spectral efficiency compared to the existing half-duplex systems. Using full-duplex communications on MIMO co-operative networks can provide us solutions that can completely outperform existing systems with simultaneous transmission and reception at high data rates.

This thesis considers a full-duplex MIMO relay which amplifies and forwards the received signals, between a source and a destination that do not a have line of sight. Full-duplex mode raises the problem of self-interference. Though all the links in the system undergo frequency flat fading, the end-to-end effective channel is frequency selective. This is due to the imperfect cancellation of the self-interference at the relay and this residual self-interference acts as intersymbol interference at the destination which is treated by equalization. This also leads to complications in form of recursive equations to determine the input-output relationship of the system. This also leads to complications in the form of recursive equations to determine the input-output relationship of the system.

To overcome this, a signal flow graph approach using Mason's gain formula is proposed, where the effective channel is analyzed with keen notice to every loop and path the signal traverses. This gives a clear understanding and awareness about the orders of the polynomials involved in the transfer function, from which desired conclusions can be drawn. But the complexity of Mason's gain formula increases with the number of antennas at relay which can be overcome by the proposed linear algebraic method. Input-output relationship derived using simple concepts of linear algebra can be generalized to any number of antennas and the computation complexity is comparatively very low.

For a full-duplex amplify-and-forward MIMO relay system, assuming equalization at the destination, new mechanisms have been implemented at the relay that can compensate the effect of residual self-interference namely equal-gain transmission and antenna selection. Though equal-gain transmission does not perform better than the maximal ratio transmission, a trade-off can be made between performance and implementation complexity. Using the proposed antenna selection strategy, one pair of transmit-receive antennas at the relay is selected based on four selection criteria discussed. Outage probability analysis is performed for all the strategies presented and detailed comparison has been established. Considering minimum mean-squared error decision feedback equalizer at the destination, a bound on the outage probability has been obtained for the antenna selection case and is used for comparisons. A cross-over point is observed while comparing the outage probabilities of equal-gain transmission and antenna selection techniques, as the signal-to-noise ratio increases and from that point antenna selection outperforms equal-gain transmission and this is explained by the fact of reduced residual self-interference in antenna selection method.
ContributorsJonnalagadda, Geeta Sankar Kalyan (Author) / Tepedelenlioğlu, Cihan (Thesis advisor) / Bliss, Daniel (Committee member) / Kosut, Oliver (Committee member) / Arizona State University (Publisher)
Created2018
156827-Thumbnail Image.png
Description
Our daily life is becoming more and more reliant on services provided by the infrastructures

power, gas , communication networks. Ensuring the security of these

infrastructures is of utmost importance. This task becomes ever more challenging as

the inter-dependence among these infrastructures grows and a security breach in one

infrastructure can spill over to

Our daily life is becoming more and more reliant on services provided by the infrastructures

power, gas , communication networks. Ensuring the security of these

infrastructures is of utmost importance. This task becomes ever more challenging as

the inter-dependence among these infrastructures grows and a security breach in one

infrastructure can spill over to the others. The implication is that the security practices/

analysis recommended for these infrastructures should be done in coordination.

This thesis, focusing on the power grid, explores strategies to secure the system that

look into the coupling of the power grid to the cyber infrastructure, used to manage

and control it, and to the gas grid, that supplies an increasing amount of reserves to

overcome contingencies.

The first part (Part I) of the thesis, including chapters 2 through 4, focuses on

the coupling of the power and the cyber infrastructure that is used for its control and

operations. The goal is to detect malicious attacks gaining information about the

operation of the power grid to later attack the system. In chapter 2, we propose a

hierarchical architecture that correlates the analysis of high resolution Micro-Phasor

Measurement Unit (microPMU) data and traffic analysis on the Supervisory Control

and Data Acquisition (SCADA) packets, to infer the security status of the grid and

detect the presence of possible intruders. An essential part of this architecture is

tied to the analysis on the microPMU data. In chapter 3 we establish a set of anomaly

detection rules on microPMU data that

flag "abnormal behavior". A placement strategy

of microPMU sensors is also proposed to maximize the sensitivity in detecting anomalies.

In chapter 4, we focus on developing rules that can localize the source of an events

using microPMU to further check whether a cyber attack is causing the anomaly, by

correlating SCADA traffic with the microPMU data analysis results. The thread that

unies the data analysis in this chapter is the fact that decision are made without fully estimating the state of the system; on the contrary, decisions are made using

a set of physical measurements that falls short by orders of magnitude to meet the

needs for observability. More specifically, in the first part of this chapter (sections 4.1-

4.2), using microPMU data in the substation, methodologies for online identification of

the source Thevenin parameters are presented. This methodology is used to identify

reconnaissance activity on the normally-open switches in the substation, initiated

by attackers to gauge its controllability over the cyber network. The applications

of this methodology in monitoring the voltage stability of the grid is also discussed.

In the second part of this chapter (sections 4.3-4.5), we investigate the localization

of faults. Since the number of PMU sensors available to carry out the inference

is insufficient to ensure observability, the problem can be viewed as that of under-sampling

a "graph signal"; the analysis leads to a PMU placement strategy that can

achieve the highest resolution in localizing the fault, for a given number of sensors.

In both cases, the results of the analysis are leveraged in the detection of cyber-physical

attacks, where microPMU data and relevant SCADA network traffic information

are compared to determine if a network breach has affected the integrity of the system

information and/or operations.

In second part of this thesis (Part II), the security analysis considers the adequacy

and reliability of schedules for the gas and power network. The motivation for

scheduling jointly supply in gas and power networks is motivated by the increasing

reliance of power grids on natural gas generators (and, indirectly, on gas pipelines)

as providing critical reserves. Chapter 5 focuses on unveiling the challenges and

providing solution to this problem.
ContributorsJamei, Mahdi (Author) / Scaglioe, Anna (Thesis advisor) / Ayyanar, Raja (Committee member) / Hedman, Kory W (Committee member) / Kosut, Oliver (Committee member) / Arizona State University (Publisher)