First, in a large-scale structure, a 3-D CFD model was built to simulate flow and temperature distributions. The flow patterns and temperature distributions are characterized and validated through spot measurements. The detailed understanding of them then allows for optimization of the HVAC configuration because identification of the problematic flow patterns

First, in a large-scale structure, a 3-D CFD model was built to simulate flow and temperature distributions. The flow patterns and temperature distributions are characterized and validated through spot measurements. The detailed understanding of them then allows for optimization of the HVAC configuration because identification of the problematic flow patterns and temperature mis-distributions leads to some corrective measures. Second, an appropriate form of the viscous dissipation term in the integral form of the conservation equation was considered, and the effects of momentum terms on the computed drop size in pressure-atomized sprays were examined. The Sauter mean diameter (SMD) calculated in this manner agrees well with experimental data of the drop velocities and sizes. Using the suggested equation with the revised treatment of liquid momentum setup, injection parameters can be directly input to the system of equations. Thus, this approach is capable of incorporating the effects of injection parameters for further considerations of the drop and velocity distributions under a wide range of spray geometry and injection conditions. Lastly, groundwater level estimation was investigated using compressed sensing (CS). To satisfy a general property of CS, a random measurement matrix was used, the groundwater network was constructed, and finally the l-1 optimization was run. Through several validation tests, correct estimation of groundwater level by CS was shown. Using this setup, decreasing trends in groundwater level in the southwestern US was shown. The suggested method is effective in that the total measurements of registered wells can be reduced down by approximately 42 %, sparse data can be visualized and a possible approach for groundwater management during extreme weather changes, e.g. in California, was demonstrated.
ContributorsLee, Joon Young (Author) / Lee, Taewoo (Thesis advisor) / Huang, Huei-Ping (Committee member) / Lopez, Juan (Committee member) / Phelan, Patrick (Committee member) / Chen, Kangping (Committee member) / Arizona State University (Publisher)
Created2015
154775-Thumbnail Image.png
Description
In the United States, buildings account for 20–40% of the total energy consumption based on their operation and maintenance, which consume nearly 80% of their energy during their lifecycle. In order to reduce building energy consumption and related problems (i.e. global warming, air pollution, and energy shortages), numerous building technology

In the United States, buildings account for 20–40% of the total energy consumption based on their operation and maintenance, which consume nearly 80% of their energy during their lifecycle. In order to reduce building energy consumption and related problems (i.e. global warming, air pollution, and energy shortages), numerous building technology programs, codes, and standards have been developed such as net-zero energy buildings, Leadership in Energy and Environmental Design (LEED), and the American Society of Heating, Refrigerating, and Air-Conditioning Engineers 90.1. However, these programs, codes, and standards are typically utilized before or during the design and construction phases. Subsequently, it is difficult to track whether buildings could still reduce energy consumption post construction. This dissertation fills the gap in knowledge of analytical methods for building energy analysis studies for LEED buildings. It also focuses on the use of green space for reducing atmospheric temperature, which contributes the most to building energy consumption. The three primary objectives of this research are to: 1) find the relationship between building energy consumption, outside atmospheric temperature, and LEED Energy and Atmosphere credits (OEP); 2) examine the use of different green space layouts for reducing the atmospheric temperature of high-rise buildings; and 3) use data mining techniques (i.e. clustering, isolation, and anomaly detection) to identify data anomalies in the energy data set and evaluate LEED Energy and Atmosphere credits based on building energy patterns. The results found that buildings with lower OEP used the highest amount of energy. LEED OEP scores tended to increase the energy saving potential of buildings, thereby reducing the need for renovation and maintenance. The results also revealed that the shade and evaporation effects of green spaces around buildings were more effective for lowering the daytime atmospheric temperature in the range of 2°C to 6.5°C. Additionally, abnormal energy consumption patterns were found in LEED buildings that used anomaly detection methodology analysis. Overall, LEED systems should be evaluated for energy performance to ensure that buildings continue to save energy after construction.
ContributorsKim, Jonghoon (Author) / Ariaratnam, Samuel T (Thesis advisor) / Chong, Oswald W (Committee member) / Bearup, Wylie K (Committee member) / Arizona State University (Publisher)