Matching Items (3)
Filtering by

Clear all filters

153166-Thumbnail Image.png
Description
ABSTRACT

X-Ray crystallography and NMR are two major ways of achieving atomic

resolution of structure determination for macro biomolecules such as proteins. Recently, new developments of hard X-ray pulsed free electron laser XFEL opened up new possibilities to break the dilemma of radiation dose and spatial resolution in diffraction imaging by outrunning

ABSTRACT

X-Ray crystallography and NMR are two major ways of achieving atomic

resolution of structure determination for macro biomolecules such as proteins. Recently, new developments of hard X-ray pulsed free electron laser XFEL opened up new possibilities to break the dilemma of radiation dose and spatial resolution in diffraction imaging by outrunning radiation damage with ultra high brightness femtosecond X-ray pulses, which is so short in time that the pulse terminates before atomic motion starts. A variety of experimental techniques for structure determination of macro biomolecules is now available including imaging of protein nanocrystals, single particles such as viruses, pump-probe experiments for time-resolved nanocrystallography, and snapshot wide- angle x-ray scattering (WAXS) from molecules in solution. However, due to the nature of the "diffract-then-destroy" process, each protein crystal would be destroyed once

probed. Hence a new sample delivery system is required to replenish the target crystal at a high rate. In this dissertation, the sample delivery systems for the application of XFELs to biomolecular imaging will be discussed and the severe challenges related to the delivering of macroscopic protein crystal in a stable controllable way with minimum waste of sample and maximum hit rate will be tackled with several different development of injector designs and approaches. New developments of the sample delivery system such as liquid mixing jet also opens up new experimental methods which gives opportunities to study of the chemical dynamics in biomolecules in a molecular structural level. The design and characterization of the system will be discussed along with future possible developments and applications. Finally, LCP injector will be discussed which is critical for the success in various applications.
ContributorsWang, Dingjie (Author) / Spence, John CH (Thesis advisor) / Weierstall, Uwe (Committee member) / Schmidt, Kevin (Committee member) / Fromme, Petra (Committee member) / Ozkan, Banu (Committee member) / Arizona State University (Publisher)
Created2014
150076-Thumbnail Image.png
Description
One of the most important issues in femtosecond free electron laser X-ray diraction is to reconstruct the 3D charge density of molecule from a mass of diraction snapshots. In order to determine the orientation of single molecule from diraction patterns, we rst determine the moments and products of inertia of

One of the most important issues in femtosecond free electron laser X-ray diraction is to reconstruct the 3D charge density of molecule from a mass of diraction snapshots. In order to determine the orientation of single molecule from diraction patterns, we rst determine the moments and products of inertia of this from 2D experiment data (diraction patterns or EM images to obtain the elements of the inertia tensor. If diraction patterns from uniformly random orientations or some preferred orientations are collected, the principal axes of the molecule can be extracted, together with the Euler angles which relate the principal axes of the molecule to the laboratory frame axes. This is achieved by nding the maximum and minimum values for the measured moments from many single-molecule patterns. Simulations for GroEL protein indicates that the calculation of the autocorrelation help eliminate the Poisson noise in Cryo- EM images and can make correct orientation determination. The eect of water jacket surrounding the protein molecule is studied based on molecular dynamics simulation result. The intensities from water and interference is found to suppress those from protein itself. A method is proposed and applied to the simulation data to show the possibility for it to overcome the water background problem. The scattering between Bragg re ections from nanocrystals is used to aid solution of the phase problem. We describe a method for reconstructing the charge density of a typical molecule within a single unit cell, if suciently nely-sampled diraction data are available from many nanocrystals of dierent sizes lying in the same orientations without knowledge of the distribution of particle size or requiring atomic-resolution data. Triple correlation of the diraction patterns are made use of to reconiii
ContributorsWang, Xiaoyu (Author) / Spence, John C.H. (Thesis advisor) / Schmidt, Kevin (Committee member) / Doak, R. Bruce (Committee member) / Weierstall, Uwe (Committee member) / Ros, Robert (Committee member) / Arizona State University (Publisher)
Created2011
153785-Thumbnail Image.png
Description
Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques.

The XFEL is characterized by high

Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques.

The XFEL is characterized by high intensity pulses, which are only about 50 femtoseconds in duration. The intensity allows for scattering from microscopic particles, while the short pulses offer a way to outrun radiation damage. XFELs are powerful enough to obliterate most samples in a single pulse. While this allows for a “diffract and destroy” methodology, it also requires instrumentation that can position microscopic particles into the X-ray beam (which may also be microscopic), continuously renew the sample after each pulse, and maintain sample viability during data collection.

Typically these experiments have used liquid microjets to continuously renew sample. The high flow rate associated with liquid microjets requires large amounts of sample, most of which runs to waste between pulses. An injector designed to stream a viscous gel-like material called lipidic cubic phase (LCP) was developed to address this problem. LCP, commonly used as a growth medium for membrane protein crystals, lends itself to low flow rate jetting and so reduces the amount of sample wasted significantly.

This work discusses sample delivery and injection for XFEL experiments. It reviews the liquid microjet method extensively, and presents the LCP injector as a novel device for serial crystallography, including detailed protocols for the LCP injector and anti-settler operation.
ContributorsJames, Daniel (Author) / Spence, John (Thesis advisor) / Weierstall, Uwe (Committee member) / Kirian, Richard (Committee member) / Schmidt, Kevin (Committee member) / Arizona State University (Publisher)
Created2015