Matching Items (5)
Filtering by

Clear all filters

153411-Thumbnail Image.png
Description
Gallium-based liquid metals are of interest for a variety of applications including flexible electronics, soft robotics, and biomedical devices. Still, nano- to microscale device fabrication with these materials is challenging because of their strong adhesion to a majority of substrates. This unusual high adhesion is attributed to the formation of

Gallium-based liquid metals are of interest for a variety of applications including flexible electronics, soft robotics, and biomedical devices. Still, nano- to microscale device fabrication with these materials is challenging because of their strong adhesion to a majority of substrates. This unusual high adhesion is attributed to the formation of a thin oxide shell; however, its role in the adhesion process has not yet been established. In the first part of the thesis, we described a multiscale study aiming at understanding the fundamental mechanisms governing wetting and adhesion of gallium-based liquid metals. In particular, macroscale dynamic contact angle measurements were coupled with Scanning Electron Microscope (SEM) imaging to relate macroscopic drop adhesion to morphology of the liquid metal-surface interface. In addition, room temperature liquid-metal microfluidic devices are also attractive systems for hyperelastic strain sensing. Currently two types of liquid metal-based strain sensors exist for inplane measurements: single-microchannel resistive and two-microchannel capacitive devices. However, with a winding serpentine channel geometry, these sensors typically have a footprint of about a square centimeter, limiting the number of sensors that can be embedded into. In the second part of the thesis, firstly, simulations and an experimental setup consisting of two GaInSn filled tubes submerged within a dielectric liquid bath are used to quantify the effects of the cylindrical electrode geometry including diameter, spacing, and meniscus shape as well as dielectric constant of the insulating liquid and the presence of tubing on the overall system's capacitance. Furthermore, a procedure for fabricating the two-liquid capacitor within a single straight polydiemethylsiloxane channel is developed. Lastly, capacitance and response of this compact device to strain and operational issues arising from complex hydrodynamics near liquid-liquid and liquid-elastomer interfaces are described.
ContributorsLiu, Shanliangzi (Author) / Rykaczewski, Konrad (Thesis advisor) / Alford, Terry (Committee member) / Herrmann, Marcus (Committee member) / Hildreth, Owen (Committee member) / Arizona State University (Publisher)
Created2015
150889-Thumbnail Image.png
Description
Pb-free solder joints are commonly used as interconnects in semiconductor packaging. One of the major defects affecting the mechanical performance of solder joints are reflow pores that form during processing. These pores exhibit significant variability in size and distribution, and understanding the effects of pore geometry on failure is an

Pb-free solder joints are commonly used as interconnects in semiconductor packaging. One of the major defects affecting the mechanical performance of solder joints are reflow pores that form during processing. These pores exhibit significant variability in size and distribution, and understanding the effects of pore geometry on failure is an important reliability concern. In this thesis, the pore microstructures of solder joint samples and the localized plastic deformation around individual pores was characterized in 3D using lab scale X-ray Microtomography. To observe the deformation of a solder joint in 3D, a solder joint was imaged with Microtomography after reflow and then deformed in shear in several loading steps with additional tomography data taken between each. The 3D tomography datasets were then segmented using the 3D Livewire technique into regions corresponding to solder and pores, and used to generate 3D models of the joint at each strain value using Mimics software. The extent of deformation of individual pores in the joint as a function of strain was quantified using sphericity measurements, and correlated with the observed cracking in the joint. In addition, the error inherent in the data acquisition and 3D modeling process was also quantified. The progression of damage observed with X-ray Microtomography was then used to validate the deformation and failure predicted by a Finite Element (FE) simulation. The FE model was based on the as-reflowed tomography data, and incorporated a ductile damage failure model to simulate fracture. Using the measured sphericity change and cracking information obtained from the tomography data, the FE model is shown to correctly capture the broad plastic deformation and strain localization seen in the actual joint, as well as the crack propagation. Lastly, Digital Image Correlation was investigated as a method of obtaining improved local strain measurements in 3D. This technique measures the displacement of the inherent microstructural features of the joint, and can give localized strain measurements that can be directly comparable to that predicted by modeling. The technique is demonstrated in 2D on Pb-Sn solder, and example 3D data is presented for future analysis.
ContributorsPadilla, Erick (Author) / Chawla, Nikhilesh (Thesis advisor) / Alford, Terry (Committee member) / Krause, Stephen (Committee member) / Arizona State University (Publisher)
Created2012
155692-Thumbnail Image.png
Description
This study explores the possibility of two matrices containing metallic particulates to act as smart materials by sensing of strain due to the presence of the conducting particles in the matrix. The first matrix is a regular Portland cement-based one while the second is a novel iron-based, carbonated binder developed

This study explores the possibility of two matrices containing metallic particulates to act as smart materials by sensing of strain due to the presence of the conducting particles in the matrix. The first matrix is a regular Portland cement-based one while the second is a novel iron-based, carbonated binder developed at ASU. Four different iron replacement percentages by volume (10%, 20%, 30% and 40%) in a Portland cement matrix were selected, whereas the best performing iron carbonate matrix developed was used. Electrical impedance spectroscopy was used to obtain the characteristic Nyquist plot before and after application of flexural load. Electrical circuit models were used to extract the changes in electrical properties under application of load. Strain sensing behavior was evaluated with respect to application of different stress levels and varying replacement levels of the inclusion. A similar approach was used to study the strain sensing capabilities of novel iron carbonate binder. It was observed that the strain sensing efficiency increased with increasing iron percentage and the resistivity increased with increase in load (or applied stress) for both the matrices. It is also found that the iron carbonate binder is more efficient in strain sensing as it had a higher gage factor when compared to the OPC matrix containing metallic inclusions.

Analytical equations (Maxwell) were used to extract frequency dependent electrical conductivity and permittivity of the cement paste (or the host matrix), interface, inclusion (iron) and voids to develop a generic electro-mechanical coupling model to for the strain sensing behavior. COMSOL Multiphysics 5.2a was used as finite element analysis software to develop the model. A MATLAB formulation was used to generate the microstructure with different volume fractions of inclusions. Material properties were assigned (the frequency dependent electrical parameters) and the coupled structural and electrical physics interface in COMSOL was used to model the strain sensing response. The experimental change in resistance matched well with the simulated values, indicating the applicability of the model to predict the strain sensing response of particulate composite systems.
ContributorsChowdhury, Swaptik (Author) / Neithalath, Narayanan (Thesis advisor) / Rajan, Subramaniam D. (Committee member) / Hoover, Christian G (Committee member) / Arizona State University (Publisher)
Created2017
155622-Thumbnail Image.png
Description
Laboratory testing was conducted to quantify strain concentrations adjacent to seams and scratches in high density polyethylene (HDPE) geomembranes. The tensile strain profile of remnants meeting the ASTM criteria for wide-width tensile testing from samples of field seams recovered for construction quality assurance testing was evaluated using digital image correlation

Laboratory testing was conducted to quantify strain concentrations adjacent to seams and scratches in high density polyethylene (HDPE) geomembranes. The tensile strain profile of remnants meeting the ASTM criteria for wide-width tensile testing from samples of field seams recovered for construction quality assurance testing was evaluated using digital image correlation (DIC). Strains adjacent to scratches on laboratory prepared samples loaded in tension were also measured using DIC. The tensile strain in the zone adjacent to a seam and the tensile strain adjacent to a scratch were compared to the tensile strains calculated using theoretical strain concentration factors. The relationship between the maximum tensile strain adjacent to a seam and the global nominal strain in the sample was quantified for textured and smooth geomembranes of common thicknesses. Using statistical analysis of the data, bounds were developed for the allowable nominal tensile strain expected to induce maximum tensile strains adjacent to the seam less than or equal to the typical yield strain of HDPE geomembranes, at several confidence levels. Where nominal strain is the global or average strain applied to the sample and maximum strain is the largest tensile strain induced in the sample.

The reduction in the nominal yield strain due to a scratch in a HDPE geomembrane was also quantified. The yield strain was approximately the same as predicted using theoretical strain concentration factors. The difference in the average measured maximum strains adjacent to the seams of textured and smooth HDPE geomembranes was found to be statistically insignificant. However, maximum strains adjacent to extrusion welded seams were somewhat greater than adjacent to fusion welded seams for nominal strains on the order of 3% to 4%. The results of the testing program suggest that the nominal tensile strain should be limited to 4% around dual hot wedge seams and 3% around extrusion fillet seams to avoid maximum strains equal to 11%, a typical yield strain for HDPE geomembranes.
ContributorsAndresen, Jake (Author) / Kavazanjian, Edward (Thesis advisor) / Houston, Sandra (Committee member) / Zapata, Claudia (Committee member) / Arizona State University (Publisher)
Created2017
154263-Thumbnail Image.png
Description
Tracking microscale targets in soft tissue using implantable probes is important in clinical applications such as neurosurgery, chemotherapy and in neurophysiological application such as brain monitoring. In most of these applications, such tracking is done with visual feedback involving some imaging modality that helps localization of the targets through images

Tracking microscale targets in soft tissue using implantable probes is important in clinical applications such as neurosurgery, chemotherapy and in neurophysiological application such as brain monitoring. In most of these applications, such tracking is done with visual feedback involving some imaging modality that helps localization of the targets through images that are co-registered with stereotaxic coordinates. However, there are applications in brain monitoring where precision targeting of microscale targets such as single neurons need to be done in the absence of such visual feedback. In all of the above mentioned applications, it is important to understand the dynamics of mechanical stress and strain induced by the movement of implantable, often microscale probes in soft viscoelastic tissue. Propagation of such stresses and strains induce inaccuracies in positioning if they are not adequately compensated. The aim of this research is to quantitatively assess (a) the lateral propagation of stress and (b) the spatio-temporal distribution of strain induced by the movement of microscale probes in soft viscoelastic tissue. Using agarose hydrogel and a silicone derivative as two different bench-top models of brain tissue, we measured stress propagation during movement of microscale probes using a sensitive load cell. We further used a solution of microscale beads and the silicone derivative to quantitatively map the strain fields using video microscopy. The above measurements were done under two different types of microelectrode movement – first, a unidirectional movement and second, a bidirectional (inch-worm like) movement both of 30 μm step-size with 3min inter-movement interval. Results indicate movements of microscale probes can induce significant stresses as far as 500 μm laterally from the location of the probe. Strain fields indicate significantly high levels of displacements (in the order of 100 μm) within 100 μm laterally from the surface of the probes. The above measurements will allow us to build precise mechanical models of soft tissue and compensators that will enhance the accuracy of tracking microscale targets in soft tissue.
ContributorsTalebianmoghaddam, Shahrzad (Author) / Muthuswamy, Jitendran (Thesis advisor) / Towe, Bruce (Committee member) / Buneo, Christopher (Committee member) / Arizona State University (Publisher)
Created2015