Matching Items (3)
Filtering by

Clear all filters

157213-Thumbnail Image.png
Description
The highly predictable structural and thermodynamic behavior of deoxynucleic acid (DNA) and ribonucleic acid (RNA) have made them versatile tools for creating artificial nanostructures over broad range. Moreover, DNA and RNA are able to interact with biological ligand as either synthetic aptamers or natural components, conferring direct biological functions to

The highly predictable structural and thermodynamic behavior of deoxynucleic acid (DNA) and ribonucleic acid (RNA) have made them versatile tools for creating artificial nanostructures over broad range. Moreover, DNA and RNA are able to interact with biological ligand as either synthetic aptamers or natural components, conferring direct biological functions to the nucleic acid devices. The applications of nucleic acids greatly relies on the bio-reactivity and specificity when applied to highly complexed biological systems.

This dissertation aims to 1) develop new strategy to identify high affinity nucleic acid aptamers against biological ligand; and 2) explore highly orthogonal RNA riboregulators in vivo for constructing multi-input gene circuits with NOT logic. With the aid of a DNA nanoscaffold, pairs of hetero-bivalent aptamers for human alpha thrombin were identified with ultra-high binding affinity in femtomolar range with displaying potent biological modulations for the enzyme activity. The newly identified bivalent aptamers enriched the aptamer tool box for future therapeutic applications in hemostasis, and also the strategy can be potentially developed for other target molecules. Secondly, by employing a three-way junction structure in the riboregulator structure through de-novo design, we identified a family of high-performance RNA-sensing translational repressors that down-regulates gene translation in response to cognate RNAs with remarkable dynamic range and orthogonality. Harnessing the 3WJ repressors as modular parts, we integrate them into biological circuits that execute universal NAND and NOR logic with up to four independent RNA inputs in Escherichia coli.
ContributorsZhou, Yu (Ph.D.) (Author) / Yan, Hao (Thesis advisor) / Green, Alexander (Thesis advisor) / Woodbury, Neal (Committee member) / Ros, Alexandra (Committee member) / Arizona State University (Publisher)
Created2019
153628-Thumbnail Image.png
Description
Biological fluids contain information-rich mixtures of biochemicals and particles such as cells, proteins, and viruses. Selective and sensitive analysis of these fluids can enable clinicians to accurately diagnose a wide range of pathologies. Fluid samples such as these present an intriguing challenge to researchers; they are packed with potentially vital

Biological fluids contain information-rich mixtures of biochemicals and particles such as cells, proteins, and viruses. Selective and sensitive analysis of these fluids can enable clinicians to accurately diagnose a wide range of pathologies. Fluid samples such as these present an intriguing challenge to researchers; they are packed with potentially vital information, but notoriously difficult to analyze. Rapid and inexpensive analysis of blood and other bodily fluids is a topic gaining substantial attention in both science and medicine. Current limitations to many analyses include long culture times, expensive reagents, and the need for specialized laboratory facilities and personnel. Improving these tests and overcoming their limitations would allow faster and more widespread testing for disease and pathogens, potentially providing a significant advantage for healthcare in many settings.

Both gradient separation techniques and dielectrophoresis can solve some of the difficulties presented by complex biological samples, thanks to selective capture, isolation, and concentration of analytes. By merging dielectrophoresis with a gradient separation-based approach, gradient insulator dielectrophoresis (g-iDEP) promises benefits in the form of rapid and specific separation of extremely similar bioparticles. High-resolution capture can be achieved by exploiting variations in the characteristic physical properties of cells and other bioparticles.

Novel implementation and application of the technique has demonstrated the isolation and concentration of blood cells from a complex biological sample, differentiation of bacterial strains within a single species, and separation of antibiotic-resistant and antibiotic-susceptible bacteria. Furthermore, this approach allows simultaneous concentration of analyte, facilitating detection and downstream analysis. A theoretical description of the resolving capabilities of g-iDEP was also developed. This theory explores the relationship between experimental parameters and resolution. Results indicate the possibility of differentiating particles with dielectrophoretic mobilities that differ by as little as one part in 100,000,000, or electrophoretic mobilities differing by as little as one part in 100,000. These results indicate the potential g-iDEP holds in terms of both separatory power and the possibility for diagnostic applications.
ContributorsJones, Paul Vernon (Author) / Hayes, Mark (Thesis advisor) / Ros, Alexandra (Committee member) / Herckes, Pierre (Committee member) / Arizona State University (Publisher)
Created2015
153855-Thumbnail Image.png
Description
Biological fluids, in particular blood plasma, provide a vital source of information on the state of human health. While specific detection of biomarker species can aid in disease diagnostics, the complexity of plasma makes analysis challenging. Despite the challenge of complex sample analysis, biomarker quantification has become a primary interest

Biological fluids, in particular blood plasma, provide a vital source of information on the state of human health. While specific detection of biomarker species can aid in disease diagnostics, the complexity of plasma makes analysis challenging. Despite the challenge of complex sample analysis, biomarker quantification has become a primary interest in biomedical analysis. Due to the extremely specific interaction between antibody and analyte, immunoassays are attractive for the analysis of these samples and have gained popularity since their initial introduction several decades ago. Current limitations to diagnostics through blood testing include long incubation times, interference from non-specific binding, and the requirement for specialized instrumentation and personnel. Optimizing the features of immunoassay for diagnostic testing and biomarker quantification would enable early and accurate detection of disease and afford rapid intervention, potentially improving patient outcomes. Improving the limit of quantitation for immunoassay has been the primary goal of many diverse experimental platforms. While the ability to accurately quantify low abundance species in a complex biological sample is of the utmost importance in diagnostic testing, models illustrating experimental limitations have relied on mathematical fittings, which cannot be directly related to finite analytical limits or fundamental relationships. By creating models based on the law of mass action, it is demonstrated that fundamental limitations are imposed by molecular shot noise, creating a finite statistical limitation to quantitative abilities. Regardless of sample volume, 131 molecules are necessary for quantitation to take place with acceptable levels of uncertainty. Understanding the fundamental limitations of the technique can aid in the design of immunoassay platforms, and assess progress toward the development of optimal diagnostic testing. A sandwich-type immunoassay was developed and tested on three separate human protein targets: myoglobin, heart-type fatty acid binding protein, and cardiac troponin I, achieving superior limits of quantitation approaching ultimate limitations. Furthermore, this approach is compatible with upstream sample separation methods, enabling the isolation of target molecules from a complex biological sample. Isolation of target species prior to analysis allows for the multiplex detection of biomarker panels in a microscale device, making the full optimization of immunoassay techniques possible for clinical diagnostics.
ContributorsWoolley, Christine F (Author) / Hayes, Mark A. (Thesis advisor) / Ros, Alexandra (Committee member) / LaBaer, Joshua (Committee member) / Arizona State University (Publisher)
Created2015