To better understand the inconsistent effects across rat motor cortex, US modulation of electrically-evoked movements was tested. A stimulation array was implanted on the cortical surface and US (200 kHz, 30-60 W/cm2 peak) was applied while measuring changes in the evoked forelimb and hindlimb movements. Direct US stimulation of the hindlimb was also studied. To test peripheral effects, rat blood glucose levels were measured while applying US near the liver.
No short-term motor modulation was visible (95% confidence interval: -3.5% to +5.1% forelimb, -3.8% to +5.5% hindlimb). There was significant long-term (minutes-order) suppression (95% confidence interval: -3.7% to -10.8% forelimb, -3.8% to -11.9% hindlimb). This suppression may be due to the considerable heating (+1.8°C between US
on-US conditions); effects of heat and US were not separable in this experiment. US directly evoked hindlimb and scrotum movements in some sessions. This required a long interval, at least 3 seconds between US bursts. Movement could be evoked with much shorter pulses than used in literature (3 ms). The EMG latency (10 ms) was compatible with activation of corticospinal neurons. The glucose modulation test showed a strong increase in a few trials, but across all trials found no significant effect.
The single motor response and the long refractory period together suggest that only the beginning of the US burst had a stimulatory effect. This would explain the lack of short-term modulation, and suggests future work with shorter pulses could better explore the missing forelimb response. During the refractory period there was no change in the electrically-evoked response, which suggests the US stimulation mechanism is independent of normal brain activity. These results challenge the literature-standard protocols and provide new insights on the unknown mechanism.
The neuromodulatory capabilities of ultrasound in tandem with electrical stimulation has a significant potential for development of neural interfaces to peripheral nerve.
Lack of proprioceptive feedback is one cause for the high upper-limb prosthesis abandonment rate. The lack of environmental interaction normalcy from unreliable proprioception creates dissatisfaction among prosthesis users. The purpose of this experiment is to investigate the effects of square breathing on learning to navigate without reliable proprioception. Square breathing is thought to influence the vagus nerve which is linked to increased learning rates. In this experiment, participants were instructed to reach toward targets in a semi-immersive virtual reality environment. Directional error, peak velocity, and peak acceleration of the reaching hand were investigated before and after participants underwent square breathing training. As the results of<br/>this experiment are inconclusive, further investigation needs to be done with larger sample sizes and examining unperturbed data to fully understand the effects of square breathing on learning new motor strategies in unreliable proprioceptive conditions.
The development of fMREIT for the direct detection of neural activity using conductivity contrast in in vivo settings has been the focus of the research work presented here. An in vivo animal model was developed to detect neural activity initiated changes in neuronal membrane conductivities under external electrical current stimulation. Neural activity was induced in somatosensory areas I (SAI) and II (SAII) by applying electrical currents between the second and fourth digits of the rodent forepaw. The in vivo animal model involved the use of forepaw stimulation to evoke somatosensory neural activations along with hippocampal fMREIT imaging currents contemporaneously applied under magnetic field strengths of 7 Tesla. Three distinct types of fMREIT current waveforms were applied as imaging currents under two inhalants – air and carbogen. Active regions in the somatosensory cortex showed significant apparent conductivity changes as variations in fMREIT phase (φ_d and ∇^2 φ_d) signals represented by fMREIT activation maps (F-tests, p <0.05). Consistent changes in the standard deviation of φ_d and ∇^2 φ_d in cortical voxels contralateral to forepaw stimulation were observed across imaging sessions. These preliminary findings show that fMREIT may have the potential to detect conductivity changes correlated with neural activity.
This study observed the effects of three different non-invasive nerve stimulation paradigms in human participants. The first study analyzed the safety and efficacy of transcutaneous auricular vagal nerve stimulation in healthy humans using a bilateral stimulation protocol with uniquely designed dry-hydrogel electrodes. Results demonstrate bilateral auricular vagal nerve stimulation has significant effects on specific parameters of autonomic activity and is safe and well tolerated. The second study analyzed the effects of non-invasive electrical stimulation of a region on the side of the neck that contains the Great Auricular Nerve and the Auricular Branch of the Vagus Nerve called the tympanomastoid fissure on golf hitting performance in healthy golfers. Results did not show significant effects on hitting performance or physiological activity, but the nerve stimulation had significant effects on reducing state-anxiety and improving the quality of feel of each shot. The third study analyzed the effects of non-invasive nerve stimulation of cervical nerves on the back of the neck on putting performance of yips-affected golfers. Results demonstrated that cervical nerve stimulation had significant effects on improving putting performance but did not have significant effects on physiological activity. Data from these studies show there are potential applications for non-invasive electrical nerve stimulation for healthy and athletic populations. Future research should also examine the effects of these stimulation methods in clinical populations.