Matching Items (2)
Filtering by

Clear all filters

155684-Thumbnail Image.png
Description
Having accurate measurements of sedentary behaviors is important to understand relationships between sedentary behaviors and health outcomes and to evaluate changes in interventions and health promotion programs designed to reduce sedentary behaviors. This dissertation included three projects that examined measurement properties of wearable monitors used to measure sedentary behaviors. Project

Having accurate measurements of sedentary behaviors is important to understand relationships between sedentary behaviors and health outcomes and to evaluate changes in interventions and health promotion programs designed to reduce sedentary behaviors. This dissertation included three projects that examined measurement properties of wearable monitors used to measure sedentary behaviors. Project one examined the validity of three monitors: the ActiGraph GT3X+, activPAL™, and SenseWear 2. None of the monitors were equivalent with the criterion measure of oxygen uptake to estimate the energy cost of sedentary and light-intensity activities. The ActivPAL™ had the best accuracy as compared with the other monitors. In project two, the accuracy of ActiGraph GT3X+and GENEActiv cut-points used to assess sedentary behavior were compared with direct observation during free-living conditions. New vector magnitude cut-points also were developed to classify time spent in sedentary- and stationary behaviors during free-living conditions. The cut-points tested had modest overall accuracy to classify sedentary time as compared to direct observation. New ActiGraph 1-minute vector cut-points increased overall accuracy for classifying sedentary time. Project 3 examined the accuracy of the sedentary sphere by testing various arm elevation- and movement-count configurations using GENEActiv and ActiGraph GT3X+ data obtained during free-living conditions. None of the configurations were equivalent to the criterion measure of direct observation. The best configuration of the GENEActiv was: worn on the dominant wrist at 15 degrees below the horizontal plane with a cut-point <489 for each 15-second interval. The best configuration for the ActiGraph was: worn on the non-dominant wrist at 5° below the horizontal plane with a cut-point of <489 counts for each 15-second interval. Collectively, these findings indicate that the wearable monitors and methods examined in this study are limited in their ability to assess sedentary behaviors and light intensity physical activity. Additional research is needed to further understand the scope and limitations of wearable monitors and methods used to assess sedentary behaviors and light intensity physical activity.
ContributorsFlorez Pregonero, Argemiro Alberto (Author) / Ainsworth, Barbara E (Thesis advisor) / Buman, Matthew P (Committee member) / Hooker, Steven P (Committee member) / Keller, Colleen S (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2017
155279-Thumbnail Image.png
Description
Background: Stroke is a leading cause of long-term disability in the United States (US). Assisted Cycling Therapy (ACT) incorporates the use of an electric motor to enhance the rotations per minute (rpm). ACT of about 80 rpm, has been associated with improvements in motor, cognitive, and clinical function. The acute

Background: Stroke is a leading cause of long-term disability in the United States (US). Assisted Cycling Therapy (ACT) incorporates the use of an electric motor to enhance the rotations per minute (rpm). ACT of about 80 rpm, has been associated with improvements in motor, cognitive, and clinical function. The acute effects of ACT on motor and cognitive function of persons with stroke induced deficits have not been investigated.

Purpose: To compare the acute effects of ACT, voluntary cycling (VC), and no cycling (NC) on upper and lower extremity motor function and executive function in adults with chronic stroke (age: 60 ± 16 years; months since stroke: 96 ± 85).

Methods: Twenty-two participants (gender: female = 6, male = 16; types: ischemic = 12, hemorrhagic = 10; sides: left lesion = 15, right lesion = 7) completed one session of ACT, one session of VC and one session of NC on separate days using a 3 x 3 crossover design.

Results: ACT lead to greater improvements in lower and upper extremity function on the paretic and non-paretic side than VC or NC (all p < 0.05), except in the non-paretic lower extremity where ACT and VC produced similar improvement (both p < 0.05). ACT and VC, but not NC, were associated with improvements in inhibition (p < 0.05). A positive relationship between cadence and motor function (P < 0.05) was found. Ratings of perceived exertion shared an inverted-U shaped relationship with measures of processing speed (p < 0.05) and a negative linear relationship with measures of executive function (p < 0.05).

Conclusion: ACT appears to benefit paretic and non-paretic motor function globally whereas the benefits of VC are more task specific. Faster cycling cadence was associated with greater improvements in global motor function. ACT and VC seem to carry similar acute benefits in inhibition.
ContributorsHolzapfel, Simon D (Author) / Ringenbach, Shannon D (Thesis advisor) / Bosch, Pamela R (Committee member) / Lee, Chong D (Committee member) / Der Ananian, Cheryl A (Committee member) / Hooker, Steven P (Committee member) / Arizona State University (Publisher)
Created2017