Matching Items (13)
Filtering by

Clear all filters

152626-Thumbnail Image.png
Description
The influence of climate variability and reclaimed wastewater on the water supply necessitates improved understanding of the treatability of trace and bulk organic matter. Dissolved organic matter (DOM) mobilized during extreme weather events and in treated wastewater includes natural organic matter (NOM), contaminants of emerging concern (CECs), and microbial extracellular

The influence of climate variability and reclaimed wastewater on the water supply necessitates improved understanding of the treatability of trace and bulk organic matter. Dissolved organic matter (DOM) mobilized during extreme weather events and in treated wastewater includes natural organic matter (NOM), contaminants of emerging concern (CECs), and microbial extracellular polymeric substances (EPS). The goal of my dissertation was to quantify the impacts of extreme weather events on DOM in surface water and downstream treatment processes, and to improve membrane filtration efficiency and CECs oxidation efficiency during water reclamation with ozone. Surface water quality, air quality and hydrologic flow rate data were used to quantify changes in DOM and turbidity following dust storms, flooding, or runoff from wildfire burn areas in central Arizona. The subsequent impacts to treatment processes and public perception of water quality were also discussed. Findings showed a correlation between dust storm events and change in surface water turbidity (R2=0.6), attenuation of increased DOM through reservoir systems, a 30-40% increase in organic carbon and a 120-600% increase in turbidity following severe flooding, and differing impacts of upland and lowland wildfires. The use of ozone to reduce membrane fouling caused by vesicles (a subcomponent of EPS) and oxidize CECs through increased hydroxyl radical (HO●) production was investigated. An "ozone dose threshold" was observed above which addition of hydrogen peroxide increased HO● production; indicating the presence of ambient promoters in wastewater. Ozonation of CECs in secondary effluent over titanium dioxide or activated carbon did not increase radial production. Vesicles fouled ultrafiltration membranes faster (20 times greater flux decline) than polysaccharides, fatty acids, or NOM. Based upon the estimated carbon distribution of secondary effluent, vesicles could be responsible for 20-60% of fouling during ultrafiltration and may play a vital role in other environmental processes as well. Ozone reduced vesicle-caused membrane fouling that, in conjunction with the presence of ambient promoters, helps to explain why low ozone dosages improve membrane flux during full-scale water reclamation.
ContributorsBarry, Michelle (Author) / Barry, Michelle C (Thesis advisor) / Westerhoff, Paul (Committee member) / Fox, Peter (Committee member) / Halden, Rolf (Committee member) / Hristovski, Kiril (Committee member) / Arizona State University (Publisher)
Created2014
153298-Thumbnail Image.png
Description
Research in microbial biofuels has dramatically increased over the last decade. The bulk of this research has focused on increasing the production yields of cyanobacteria and algal cells and improving extraction processes. However, there has been little to no research on the potential impact of viruses on the yields of

Research in microbial biofuels has dramatically increased over the last decade. The bulk of this research has focused on increasing the production yields of cyanobacteria and algal cells and improving extraction processes. However, there has been little to no research on the potential impact of viruses on the yields of these phototrophic microbes for biofuel production. Viruses have the potential to significantly reduce microbial populations and limit their growth rates. It is therefore important to understand how viruses affect phototrophic microbes and the prevalence of these viruses in the environment. For this study, phototrophic microbes were grown in glass bioreactors, under continuous light and aeration. Detection and quantification of viruses of both environmental and laboratory microbial strains were measured through the use of a plaque assay. Plates were incubated at 25º C under continuous direct florescent light. Several environmental samples were taken from Tempe Town Lake (Tempe, AZ) and all the samples tested positive for viruses. Virus free phototrophic microbes were obtained from plaque assay plates by using a sterile loop to scoop up a virus free portion of the microbial lawn and transferred into a new bioreactor. Isolated cells were confirmed virus free through subsequent plaque assays. Viruses were detected from the bench scale bioreactors of Cyanobacteria Synechocystis PCC 6803 and the environmental samples. Viruses were consistently present through subsequent passage in fresh cultures; demonstrating viral contamination can be a chronic problem. In addition TEM was performed to examine presence or viral attachment to cyanobacterial cells and to characterize viral particles morphology. Electron micrographs obtained confirmed viral attachment and that the viruses detected were all of a similar size and shape. Particle sizes were measured to be approximately 50-60 nm. Cell reduction was observed as a decrease in optical density, with a transition from a dark green to a yellow green color for the cultures. Phototrophic microbial viruses were demonstrated to persist in the natural environment and to cause a reduction in algal populations in the bioreactors. Therefore it is likely that viruses could have a significant impact on microbial biofuel production by limiting the yields of production ponds.
ContributorsKraft, Kyle (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2014
156007-Thumbnail Image.png
Description
Granular activated carbon (GAC) is effectively used to remove natural organic matter (NOM) and to assist in the removal of disinfection byproducts (DBPs) and their precursors. However, operation of GAC is cost- and labor-intensive due to frequent media replacement. Optimizing the use of GAC is necessary to ensure treatment efficiency

Granular activated carbon (GAC) is effectively used to remove natural organic matter (NOM) and to assist in the removal of disinfection byproducts (DBPs) and their precursors. However, operation of GAC is cost- and labor-intensive due to frequent media replacement. Optimizing the use of GAC is necessary to ensure treatment efficiency while reducing costs. This dissertation presents four strategies to reduce improve GAC usage while reducing formation of DBPs. The first part of this work adopts Rapid Small Scale Tests (RSSCTs) to evaluate removal of molecular weight fractions of NOM, characterized using size exclusion chromatography (SECDOC). Total trihalomethanes (TTHM), haloacetic acids (HAA5) and haloacetonitriles (HAN) formation were quantified after treatment with GAC. Low MW NOM was removed preferentially in the early bed volumes, up until exhaustion of available adsorption sites. DBP formation potential lowered with DOC removal. Chlorination prior to GAC is investigated in the second part of this work as a strategy to increase removal of NOM and DBP precursors. Results showed lower TTHM formation in the effluent of the GAC treatment when pre-chlorination was adopted, meaning this strategy could help optimize and extend the bed life if GAC filters. The third part of this work investigates in-situ GAC regeneration as an alternative to recover adsorption capacity of field-spent GAC that could potentially offer new modes of operation for water treatment facilities while savng costs with reactivation of spent GAC in an external facility. Field-spent GACs were treated with different oxidant solutions and recovery in adsorption capacity was evaluated for NOM and for two micro pollutants. Recovery of GAC adsorption capacity was not satisfactory for most of conditions evaluated. This indicates that in-situ GAC regeneration could be more effective when the adsorbates are present at high concentrations. Lastly, this work investigates the impact of low molecular weight polyDADMAC on N-nitrosodimethylamine (NDMA) formation. Water treatment facilities rely on polyDADMAC as a coagulant aid to comply with NOM removal and turbidity requirements. Since polymer-derived NDMA precursors are not removed by GAC, it is essential to optimize the use and synthesis of polyDADMAC to reduce NDMA precursors during water treatment.
ContributorsFischer, Natalia (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2017
157123-Thumbnail Image.png
Description
In the recent past, Iraq was considered relatively rich considering its water resources compared to its surroundings. Currently, the magnitude of water resource shortages in Iraq represents an important factor in the stability of the country and in protecting sustained economic development. The need for a practical, applicable, and sustainable

In the recent past, Iraq was considered relatively rich considering its water resources compared to its surroundings. Currently, the magnitude of water resource shortages in Iraq represents an important factor in the stability of the country and in protecting sustained economic development. The need for a practical, applicable, and sustainable river basin management for the Tigris and Euphrates Rivers in Iraq is essential. Applicable water resources allocation scenarios are important to minimize the potential future water crises in connection with water quality and quantity. The allocation of the available fresh water resources in addition to reclaimed water to different users in a sustainable manner is of the urgent necessities to maintain good water quantity and quality.

In this dissertation, predictive water allocation optimization models were developed which can be used to easily identify good alternatives for water management that can then be discussed, debated, adjusted, and simulated in greater detail. This study provides guidance for decision makers in Iraq for potential future conditions, where water supplies are reduced, and demonstrates how it is feasible to adopt an efficient water allocation strategy with flexibility in providing equitable water resource allocation considering alternative resource. Using reclaimed water will help in reducing the potential negative environmental impacts of treated or/and partially treated wastewater discharges while increasing the potential uses of reclaimed water for agriculture and other applications. Using reclaimed water for irrigation is logical and efficient to enhance the economy of farmers and the environment while providing a diversity of crops, especially since most of Iraq’s built or under construction wastewater treatment plants are located in or adjacent to agricultural lands. Adopting an optimization modelling approach can assist decision makers, ensuring their decisions will benefit the economy by incorporating global experiences to control water allocations in Iraq especially considering diminished water supplies.
ContributorsAhmed, Ahmed Abdulrazzaq (Author) / Mays, Larry W. (Thesis advisor) / Fox, Peter (Thesis advisor) / Mascaro, Giuseppe (Committee member) / Muenich, Rebecca (Committee member) / Arizona State University (Publisher)
Created2019
157075-Thumbnail Image.png
Description
The phrase water-energy nexus is commonly used to describe the inherent and critical interdependencies between the electric power system and the water supply systems (WSS). The key interdependencies between the two systems are the power plant’s requirement of water for the cooling cycle and the water system’s need of electricity

The phrase water-energy nexus is commonly used to describe the inherent and critical interdependencies between the electric power system and the water supply systems (WSS). The key interdependencies between the two systems are the power plant’s requirement of water for the cooling cycle and the water system’s need of electricity for pumping for water supply. While previous work has considered the dependency of WSS on the electrical power, this work incorporates into an optimization-simulation framework, consideration of the impact of short and long-term limited availability of water and/or electrical energy.

This research focuses on the water supply system (WSS) facet of the multi-faceted optimization and control mechanism developed for an integrated water – energy nexus system under U.S. National Science Foundation (NSF) project 029013-0010 CRISP Type 2 – Resilient cyber-enabled electric energy and water infrastructures modeling and control under extreme mega drought scenarios. A water supply system (WSS) conveys water from sources (such as lakes, rivers, dams etc.) to the treatment plants and then to users via the water distribution systems (WDS) and/or water supply canal systems (WSCS). Optimization-simulation methodologies are developed for the real-time operation of water supply systems (WSS) under critical conditions of limited electrical energy and/or water availability due to emergencies such as extreme drought conditions, electric grid failure, and other severe conditions including natural and manmade disasters. The coupling between WSS and the power system was done through alternatively exchanging data between the power system and WSS simulations via a program control overlay developed in python.

A new methodology for WDS infrastructural-operational resilience (IOR) computation was developed as a part of this research to assess the real-time performance of the WDS under emergency conditions. The methodology combines operational resilience and component level infrastructural robustness to provide a comprehensive performance assessment tool.

The optimization-simulation and resilience computation methodologies developed were tested for both hypothetical and real example WDS and WSCS, with results depicting improved resilience for operations of the WSS under normal and emergency conditions.
ContributorsKhatavkar, Puneet (Author) / Mays, Larry W. (Thesis advisor) / Vittal, Vijay (Committee member) / Mascaro, Giuseppe (Committee member) / Fox, Peter (Committee member) / Zhang, Junshan (Committee member) / Arizona State University (Publisher)
Created2019
134194-Thumbnail Image.png
Description
This report analyzes the potential for accumulation of boron in direct potable reuse. Direct potable reuse treats water through desalination processes such as reverse osmosis or nanofiltration which can achieve rejection rates of salts sometimes above 90%. However, boron achieves much lower rejection rates near 40%. Because of this low

This report analyzes the potential for accumulation of boron in direct potable reuse. Direct potable reuse treats water through desalination processes such as reverse osmosis or nanofiltration which can achieve rejection rates of salts sometimes above 90%. However, boron achieves much lower rejection rates near 40%. Because of this low rejection rate, there is potential for boron to accumulate in the system to levels that are not recommended for potable human consumption of water. To analyze this issue a code was created that runs a steady state system that tracks the internal concentration, permeate concentration, wastewater concentration and reject concentration at various rejection rates, as well as all the flows. A series of flow and mass balances were performed through five different control volumes that denoted different stages in the water use. First was mixing of clean water with permeate; second, consumptive uses; third, addition of contaminant; fourth, wastewater treatment; fifth, advanced water treatments. The system cycled through each of these a number of times until steady state was reached. Utilities or cities considering employing direct potable reuse could utilize this model by estimating their consumption levels and input of contamination, and then seeing what percent rejection or inflow of makeup water they would need to obtain to keep boron levels at a low enough concentration to be fit for consumption. This code also provides options for analyzing spikes and recovery in the system due to spills, and evaporative uses such as cooling towers and their impact on the system.
ContributorsDoidge, Sydney (Author) / Fox, Peter (Thesis director) / Perreault, Francois (Committee member) / Civil, Environmental and Sustainable Engineering Program (Contributor) / School of International Letters and Cultures (Contributor) / Barrett, The Honors College (Contributor)
Created2017-12
155850-Thumbnail Image.png
Description
This study was designed to provide insight into microbial transport kinetics which might be applied to bioremediation technology development and prevention of groundwater susceptibility to pathogen contamination. Several pilot-scale experiments were conducted in a saturated, 2 dimensional, packed porous media tank to investigate the transport of Escherichia coli bacteria, P22

This study was designed to provide insight into microbial transport kinetics which might be applied to bioremediation technology development and prevention of groundwater susceptibility to pathogen contamination. Several pilot-scale experiments were conducted in a saturated, 2 dimensional, packed porous media tank to investigate the transport of Escherichia coli bacteria, P22 bacteriophage, and a visual tracer and draw comparisons and/or conclusions. A constructed tank was packed with an approximate 3,700 cubic inches (in3) of a fine grained, homogeneous, chemically inert sand which allowed for a controlled system. Sampling ports were located at 5, 15, 25, and 25 vertical inches from the base of the 39 inch saturated zone and were used to assess the transport of the selected microorganisms. Approximately 105 cells of E. coli or P22 were injected into the tank and allowed to move through the media at approximately 10.02 inches per day. Samples were collected intermittently after injection based off of an estimated sampling schedule established from the visual tracer.

The results suggest that bacteriophages pass through soil faster and with greater recovery than bacteria. P22 in the tank reservoir experienced approximately 1 log reduction after 36 hours. After 85 hours, P22 was still detected in the reservoir after experiencing a 2 log reduction from the start of the experiment. E. coli either did not reach the outlet or died before sampling, while P22 was able to be recovered. Bacterial breakthrough curves were produced for the microbial indicators and illustrate the peak concentrations found for each sampling port. For E. coli, concentrations at the 5 inch port peaked at a maximum of 5170 CFU/mL, and eventually at the 25 inch port at a maximum of 90 CFU/mL. It is presumed that E. coli might have experienced significant filtration, straining and attachment, while P22 might have experienced little adsorption and instead was transported rapidly in long distances and was able to survive for the duration of the experiment.
ContributorsAcosta, Jazlyn Cauren (Author) / Abbaszadegan, Morteza (Thesis advisor) / Dahlen, Paul (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2017
149595-Thumbnail Image.png
Description
The objective of this research was to predict the persistence of potential future contaminants in indirect potable reuse systems. In order to accurately estimate the fates of future contaminants in indirect potable reuse systems, results describing persistence from EPI Suite were modified to include sorption and oxidation. The target future

The objective of this research was to predict the persistence of potential future contaminants in indirect potable reuse systems. In order to accurately estimate the fates of future contaminants in indirect potable reuse systems, results describing persistence from EPI Suite were modified to include sorption and oxidation. The target future contaminants studied were the approximately 2000 pharmaceuticals currently undergoing testing by United States Food and Drug Administration (US FDA). Specific organic substances such as analgesics, antibiotics, and pesticides were used to verify the predicted half-lives by comparing with reported values in the literature. During sub-surface transport, an important component of indirect potable reuse systems, the effects of sorption and oxidation are important mechanisms. These mechanisms are not considered by the quantitative structure activity relationship (QSAR) model predictions for half-lives from EPI Suite. Modifying the predictions from EPI Suite to include the effects of sorption and oxidation greatly improved the accuracy of predictions in the sub-surface environment. During validation, the error was reduced by over 50% when the predictions were modified to include sorption and oxidation. Molecular weight (MW) is an important criteria for estimating the persistence of chemicals in the sub-surface environment. EPI Suite predicts that high MW compounds are persistent since the QSAR model assumes steric hindrances will prevent transformations. Therefore, results from EPI Suite can be very misleading for high MW compounds. Persistence was affected by the total number of halogen atoms in chemicals more than the sum of N-heterocyclic aromatics in chemicals. Most contaminants (over 90%) were non-persistent in the sub-surface environment suggesting that the target future drugs do not pose a significant risk to potable reuse systems. Another important finding is that the percentage of compounds produced from the biotechnology industry is increasing rapidly and should dominate the future production of pharmaceuticals. In turn, pharmaceuticals should become less persistent in the future. An evaluation of indirect potable reuse systems that use reverse osmosis (RO) for potential rejection of the target contaminants was performed by statistical analysis. Most target compounds (over 95%) can be removed by RO based on size rejection and other removal mechanisms.
ContributorsLim, Seung (Author) / Fox, Peter (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Halden, Rolf (Committee member) / Arizona State University (Publisher)
Created2011
157964-Thumbnail Image.png
Description
This dissertation investigates the mechanisms that lead to fouling, as well as how an understanding of how these mechanisms can be leveraged to mitigate fouling.

To limit fouling on feed spacers, various coatings were applied. The results showed silver-coated biocidal spacers outperformed other spacers by all measures. The control polypropylene

This dissertation investigates the mechanisms that lead to fouling, as well as how an understanding of how these mechanisms can be leveraged to mitigate fouling.

To limit fouling on feed spacers, various coatings were applied. The results showed silver-coated biocidal spacers outperformed other spacers by all measures. The control polypropylene spacers performed in-line with, or better than, the other coatings. Polypropylene’s relative anti-adhesiveness is due to its surface free energy (SFE; 30.0 +/- 2.8 mN/m), which, according to previously generated models, is near the ideal SFE for resisting adhesion of bacteria and organics (~25 mN/m).

Previous research has indicated that electrochemical surfaces can be used to remove biofilms. To better elucidate the conditions and kinetics of biofilm removal, optical coherence tomography microscopy was used to visualize the biofouling and subsequent cleaning of the surface. The 50.0 mA cm-2 and 87.5 mA cm-2 current densities proved most effective in removing the biofilm. The 50.0 mA cm-2 condition offers the best balance between performance and energy use for anodic operation.

To test the potential to incorporate electrochemical coatings into infrastructure, membranes were coated with carbon nanotubes (CNTs), rendering the membranes electrochemically active. These membranes were biofouled and subsequently cleaned via electrochemical reactions. P. aeruginosa was given 72h to develop a biofilm on the CNT-coated membranes in a synthetic medium simulating desalination brines. Cathodic reactions, which generate H2 gas, produce vigorous bubbling at a current density of 12.5 mA cm-2 and higher, leading to a rapid and complete displacement of the biofilm from the CNT-functionalized membrane surface. In comparison, anodic reactions were unable to disperse the biofilms from the surface at similar current densities.

The scaling behavior of a nanophotonics-enabled solar membrane distillation (NESMD) system was investigated. The results showed the NESMD system to be resistant to scaling. The system operated without any decline in flux up to concentrations 6x higher than the initial salt concentration (8,439 mg/L), whereas in traditional membrane distillation (MD), flux essentially stopped at a salt concentration factor of 2x. Microscope and analytical analyses showed more fouling on the membranes from the MD system.
ContributorsRice, Douglas, Ph.D (Author) / Perreault, Francois (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Fox, Peter (Committee member) / Lind-Thomas, Mary Laura (Committee member) / Arizona State University (Publisher)
Created2019
157746-Thumbnail Image.png
Description
Imagine you live in a place without any storm water or wastewater systems!

Wastewater and storm water systems are two of the most crucial systems for urban infrastructure. Water resources have become more limited and expensive in arid and semi-arid regions. According to the fourth World Water Development Report, over

Imagine you live in a place without any storm water or wastewater systems!

Wastewater and storm water systems are two of the most crucial systems for urban infrastructure. Water resources have become more limited and expensive in arid and semi-arid regions. According to the fourth World Water Development Report, over 80% of global wastewater is released into the environment without adequate treatment. Wastewater collection and treatment systems in the Kingdom of Saudi Arabia (KSA) covers about 49% of urban areas; about 25% of treated wastewater is used for landscape and crop irrigation (Ministry of Environment Water and Agriculture [MEWA], 2017). According to Guizani (2016), during each event of flooding, there are fatalities. In 2009, the most deadly flood occurred in Jeddah, KSA within more than 160 lives lost. As a consequence, KSA has set a goal to provide 100% sewage collection and treatment services to every city with a population above 5000 by 2025, where all treated wastewater will be used.

This research explores several optimization models of planning and designing collection systems, such as regional wastewater and stormwater systems, in order to understand and overcome major performance-related disadvantages and high capital costs. The first model (M-1) was developed for planning regional wastewater system, considering minimum costs of location, type, and size sewer network and wastewater treatment plants (WWTPs). The second model (M-2) was developed for designing a regional wastewater system, considering minimum hydraulic design costs, such as pump stations, commercial diameters, excavation costs, and WWTPs. Both models were applied to the Jizan region, KSA.

The third model (M-3) was developed to solve layout and pipe design for storm water systems simultaneously. This model was applied to four different case scenarios, using two approaches for commercial diameters. The fourth model (M-4) was developed to solve the optimum pipe design of a storm sewer system for given layouts. However, M-4 was applied to a storm sewer network published in the literature.

M-1, M-2, and M-3 were developed in the general algebraic modeling system (GAMS) program, which was formulated as a mixed integer nonlinear programming (MINLP) solver, while M-4 was formulated as a nonlinear programming (NLP) procedure.
ContributorsAlfaisal, Faisal M (Author) / Mays, Larry W. (Thesis advisor) / Mascaro, Giuseppe (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2019