Matching Items (6)
Filtering by

Clear all filters

154169-Thumbnail Image.png
Description
Arsenic (As) is a naturally occurring element that poses a health risk when continually consumed at levels exceeding the Environmental Protection Agencies (EPA) maximum contaminant level (MCL) of 10 ppb. With the Arizona Department of Water Resources considering reliance on other sources of water other than just solely surface water,

Arsenic (As) is a naturally occurring element that poses a health risk when continually consumed at levels exceeding the Environmental Protection Agencies (EPA) maximum contaminant level (MCL) of 10 ppb. With the Arizona Department of Water Resources considering reliance on other sources of water other than just solely surface water, groundwater proves a reliable, supplemental source. The Salt River Project (SRP) wants to effectively treat their noncompliance groundwater sources to meet EPA compliance. Rapid small-scale column tests (RSSCTs) of two SRP controlled groundwater wells along the Eastern Canal and Consolidated Canal were designed to assist SRP in selection and future design of full-scale packed bed adsorbent media. Main concerns for column choice is effectiveness, design space at groundwater wells, and simplicity. Two adsorbent media types were tested for effective treatment of As to below the MCL: a synthetic iron oxide, Bayoxide E33, and a strong base anion exchange resin, SBG-1. Both media have high affinity toward As and prove effective at treating As from these groundwater sources. Bayoxide E33 RSSCT performance indicated that As treatment lasted to near 60,000 bed volumes (BV) in both water sources and still showed As adsorption extending past this operation ranging from several months to a year. SBG-1 RSSCT performance indicated As, treatment lasted to 500 BV, with the added benefit of being regenerated. At 5%, 13%, and 25% brine regeneration concentrations, regeneration showed that 5% brine is effective, yet would complicate overall design and footprint. Bayoxide E33 was selected as the best adsorbent media for SRP use in full-scale columns at groundwater wells due to its simplistic design and high efficiency.
ContributorsLesan, Dylan (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Committee member) / Fraser, Matthew (Committee member) / Arizona State University (Publisher)
Created2015
156029-Thumbnail Image.png
Description
With the application of reverse osmosis (RO) membranes in the wastewater treatment and seawater desalination, the limitation of flux and fouling problems of RO have gained more attention from researchers. Because of the tunable structure and physicochemical properties of nanomaterials, it is a suitable material that can be used to

With the application of reverse osmosis (RO) membranes in the wastewater treatment and seawater desalination, the limitation of flux and fouling problems of RO have gained more attention from researchers. Because of the tunable structure and physicochemical properties of nanomaterials, it is a suitable material that can be used to incorporate with RO to change the membrane performances. Silver is biocidal, which has been used in a variety of consumer products. Recent studies showed that fabricating silver nanoparticles (AgNPs) on membrane surfaces can mitigate the biofouling problem on the membrane. Studies have shown that Ag released from the membrane in the form of either Ag ions or AgNP will accelerate the antimicrobial activity of the membrane. However, the silver release from the membrane will lower the silver loading on the membrane, which will eventually shorten the antimicrobial activity lifetime of the membrane. Therefore, the silver leaching amount is a crucial parameter that needs to be determined for every type of Ag composite membrane.

This study is attempting to compare four different silver leaching test methods, to study the silver leaching potential of the silver impregnated membranes, conducting the advantages and disadvantages of the leaching methods. An In-situ reduction Ag loaded RO membrane was examined in this study. A custom waterjet test was established to create a high-velocity water flow to test the silver leaching from the nanocomposite membrane in a relative extreme environment. The batch leaching test was examined as the most common leaching test method for the silver composite membrane. The cross-flow filtration and dead-end test were also examined to compare the silver leaching amounts.

The silver coated membrane used in this experiment has an initial silver loading of 2.0± 0.51 ug/cm2. The mass balance was conducted for all of the leaching tests. For the batch test, water jet test, and dead-end filtration, the mass balances are all within 100±25%, which is acceptable in this experiment because of the variance of the initial silver loading on the membranes. A bad silver mass balance was observed at cross-flow filtration. Both of AgNP and Ag ions leached in the solution was examined in this experiment. The concentration of total silver leaching into solutions from the four leaching tests are all below the Secondary Drinking Water Standard for silver which is 100 ppb. The cross-flow test is the most aggressive leaching method, which has more than 80% of silver leached from the membrane after 50 hours of the test. The water jet (54 ± 6.9% of silver remaining) can cause higher silver leaching than batch test (85 ± 1.2% of silver remaining) in one-hour, and it can also cause both AgNP and Ag ions leaching from the membrane, which is closer to the leaching condition in the cross-flow test.
ContributorsHan, Bingru (Author) / Westerhoff, Paul (Thesis advisor) / Perreault, Francois (Committee member) / Sinha, Shahnawaz (Committee member) / Arizona State University (Publisher)
Created2017
156589-Thumbnail Image.png
Description
The volume of end-of-life photovoltaic (PV) modules is increasing as the global PV market increases, and the global PV waste streams are expected to reach 250,000 metric tons by the end of 2020. If the recycling processes are not in place, there would be 60 million tons of end-of-life PV

The volume of end-of-life photovoltaic (PV) modules is increasing as the global PV market increases, and the global PV waste streams are expected to reach 250,000 metric tons by the end of 2020. If the recycling processes are not in place, there would be 60 million tons of end-of-life PV modules lying in the landfills by 2050, that may not become a not-so-sustainable way of sourcing energy since all PV modules could contain certain amount of toxic substances. Currently in the United States, PV modules are categorized as general waste and can be disposed in landfills. However, potential leaching of toxic chemicals and materials, if any, from broken end-of-life modules may pose health or environmental risks. There is no standard procedure to remove samples from PV modules for chemical toxicity testing in the Toxicity Characteristic Leaching Procedure (TCLP) laboratories as per EPA 1311 standard. The main objective of this thesis is to develop an unbiased sampling approach for the TCLP testing of PV modules. The TCLP testing was concentrated only for the laminate part of the modules, as they are already existing recycling technologies for the frame and junction box components of PV modules. Four different sample removal methods have been applied to the laminates of five different module manufacturers: coring approach, cell-cut approach, strip-cut approach, and hybrid approach. These removed samples were sent to two different TCLP laboratories, and TCLP results were tested for repeatability within a lab and reproducibility between the labs. The pros and cons of each sample removal method have been explored and the influence of sample removal methods on the variability of TCLP results has been discussed. To reduce the variability of TCLP results to an acceptable level, additional improvements in the coring approach, the best of the four tested options, are still needed.
ContributorsLeslie, Joswin (Author) / Tamizhmani, Govindasamy (Thesis advisor) / Srinivasan, Devarajan (Committee member) / Kuitche, Joseph (Committee member) / Arizona State University (Publisher)
Created2018
187839-Thumbnail Image.png
Description
Generally, porous structures are nano-enabled with a high loading of nanoparticles (NPs) to enhance adsorption capacity, but pore blockage plays a determinant role in kinetics in this approach. The goal of this study is to investigate the effect of NPs loading on the adsorption kinetics and capacity of titanium dioxide

Generally, porous structures are nano-enabled with a high loading of nanoparticles (NPs) to enhance adsorption capacity, but pore blockage plays a determinant role in kinetics in this approach. The goal of this study is to investigate the effect of NPs loading on the adsorption kinetics and capacity of titanium dioxide (TiO2). To accomplish this, side-emitting optical fibers impregnated with different mass loadings of TiO2 (Ti-NIFs) were developed and characterized. Additionally, taking advantage of the use of optical fibers, the potential influence of ultraviolet light (UV) irradiation in arsenate adsorption over TiO2 was studied. The adsorption kinetics and capacity of Ti-NIFs were compared with slurry TiO2 nanoparticles in batch reactors. Arsenate adsorption was evaluated under both UV irradiation and dark conditions. The Ti-NIF with the lowest TiO2 loading showed comparable adsorption rate to NPs in suspension. Higher loadings resulted in high mass-transfer limitations. Interestingly, the normalized adsorption capacity of the produced Ti-NIFs maintained the adsorption capacity similar as they were freely dispersed. The experiments showed that UV has no influence in arsenate adsorption onto TiO2, contrary to previous literature indicating a positive effect, which was likely due to pH drift. Overall, this study shows that loadings of nanoparticles below 1% effectively enhance nano-enabled surfaces' performance.
ContributorsGonzalez Rodriguez, Jose Ricardo (Author) / Westerhoff, Paul (Thesis advisor) / Garcia-Segura, Sergi (Committee member) / Hristovski, Kiril (Committee member) / Arizona State University (Publisher)
Created2023
171723-Thumbnail Image.png
Description
Plastics, when released into the environment, undergo surface weathering due to mechanical abrasion and ultraviolet (UV) exposure that leads to the formation of microplastics. Weathering also introduces oxygen functional groups on the surface, which will affect surface interactions compared to pristine plastics. In this study, the adsorption of selected model

Plastics, when released into the environment, undergo surface weathering due to mechanical abrasion and ultraviolet (UV) exposure that leads to the formation of microplastics. Weathering also introduces oxygen functional groups on the surface, which will affect surface interactions compared to pristine plastics. In this study, the adsorption of selected model contaminants of high environmental relevance was evaluated at different level of abiotic and biotic transformation to understand how microplastics aging influences contaminant adsorption on high density polyethylene (HDPE) and polypropylene (PPE). Microplastics were aged through an accelerated weathering process using UV exposure with or without hydrogen peroxide. The effect of UV aging on the microplastics’ morphology and surface chemistry was characterized by Fourier Transform Infrared Spectroscopy, X-Ray Photoelectron Spectroscopy, streaming Zeta potential, Brunauer–Emmett–Teller Krypton adsorption analyses and Computed X-Ray Tomography. Sorption of organic contaminants was found to be higher on aged microplastics compared to pristine ones for all contaminants investigated. This increase in sorption affinity was found to be associated with a change in the surface chemistry and not in an increase in specific surface area after aging. Biological surface weathering (i.e., biofilm formation) was carried out at a lab-scale setting using model biofilm-forming bacteria followed by adsorption affinity measurement of biofilm-laden microplastics with the model organic contaminants. The amount of microbial biomass accumulated on the surface was also evaluated to correlate the changes in sorption affinity with the change in microplastic biofilm formation. The results of this study emphasize the need to understand how contaminant-microplastics interactions will evolve as microplastics are altered by biotic and abiotic factors in the environment.
ContributorsBhagat, Kartik (Author) / Perreault, Francois (Thesis advisor) / Westerhoff, Paul (Committee member) / Oswald, Jay (Committee member) / Arizona State University (Publisher)
Created2022
158198-Thumbnail Image.png
Description
Per- and polyfluoroalkyl substances (PFAS) are a group of man-made chemicals that are detected ubiquitously in the aquatic environment, biota, and humans. Human exposure and adverse health of PFAS through consuming impacted drinking water is getting regulatory attention. Adsorption using granular activated carbon (GAC) and ion exchange resin (IX) has

Per- and polyfluoroalkyl substances (PFAS) are a group of man-made chemicals that are detected ubiquitously in the aquatic environment, biota, and humans. Human exposure and adverse health of PFAS through consuming impacted drinking water is getting regulatory attention. Adsorption using granular activated carbon (GAC) and ion exchange resin (IX) has proved to be efficient in removing PFAS from water. There is a need to study the effectiveness of commercially available sorbents in PFAS removal at the pilot-scale with real PFAS contaminated water, which would aid in efficient full-scale plant design. Additionally, there is also a need to have validated bench-scale testing techniques to aid municipalities and researchers in selecting or comparing adsorbents to remove PFAS. Rapid Small-Scale Column Tests (RSSCTs) are bench-scale testing to assess media performance and operational life to remove trace organics but have not been validated for PFAS. Different design considerations exist for RSSCTs, which rely upon either proportional diffusivity (PD) or constant diffusivity (CD) dimensionless scaling relationships.

This thesis aims to validate the use of RSSCTs to simulate PFAS breakthrough in pilot columns. First, a pilot-scale study using two GACs and an IX was conducted for five months at a wellsite in central Arizona. PFAS adsorption capacity was greatest for a commercial IX, and then two GAC sources exhibited similar performance. Second, RSSCTs scaled using PD or CD relationships, simulated the pilot columns, were designed and performed. For IX and the two types of GAC, the CD–RSSCTs simulated the PFAS breakthrough concentration, shape, and order of C8 to C4 compounds observed pilot columns better than the PD-RSSCTs. Finally, PFAS breakthrough and adsorption capacities for PD- and CD-RSSCTs were performed on multiple groundwaters (GWs) from across Arizona to assess the treatability of PFAS chain length and functional head-group moieties. PFAS breakthrough in GAC and IX was dictated by chain length (C4>C6>C8) and functional group (PFCAs>PFSAs) of the compound. Shorter-chain PFAS broke through earlier than the longer chain, and removal trends were related to the hydrophobicity of PFAS. Overall, single-use IX performed superior to any of the evaluated GACs across a range of water chemistries in Arizona GWs.
ContributorsVenkatesh, Krishishvar (Author) / Westerhoff, Paul (Thesis advisor) / Sinha, Shahnawaz (Committee member) / Lind, Marylaura (Committee member) / Arizona State University (Publisher)
Created2020