The most widely used technique for brain functional imaging is functional Magnetic Resonance Image (fMRI). The spatial resolution of fMRI is high. However, fMRI signals are highly influenced by the vasculature in each voxel and can be affected by capillary orientation and vessel size. Functional MRI analysis may, therefore, produce misleading results when voxels are nearby large vessels. Another problem in fMRI is that hemodynamic responses are slower than the neuronal activity. Therefore, temporal resolution is limited in fMRI. Furthermore, the correlation between neural activity and the hemodynamic response is not fully understood. fMRI can only be considered an indirect method of functional brain imaging.
Another MR-based method of functional brain mapping is neuronal current magnetic resonance imaging (ncMRI), which has been studied over several years. However, the amplitude of these neuronal current signals is an order of magnitude smaller than the physiological noise. Works on ncMRI include simulation, phantom experiments, and studies in tissue including isolated ganglia, optic nerves, and human brains. However, ncMRI development has been hampered due to the extremely small signal amplitude, as well as the presence of confounding signals from hemodynamic changes and other physiological noise.
Magnetic Resonance Electrical Impedance Tomography (MREIT) methods could have the potential for the detection of neuronal activity. In this technique, small external currents are applied to a body during MR scans. This current flow produces a magnetic field as well as an electric field. The altered magnetic flux density along the main magnetic field direction caused by this current flow can be obtained from phase images. When there is neural activity, the conductivity of the neural cell membrane changes and the current paths around the neurons change consequently. Neural spiking activity during external current injection, therefore, causes differential phase accumulation in MR data. Statistical analysis methods can be used to identify neuronal-current-induced magnetic field changes.
The methods developed in this work improve the spatial coverage of whole-brain DSC-MRI by combining a highly efficient 3D spiral k-space trajectory with Generalized Autocalibrating Partial Parallel Acquisition (GRAPPA) parallel imaging without increasing temporal resolution. The proposed method is capable of acquiring 30 slices with a temporal resolution of under 1 second, covering the entire cerebrum with isotropic spatial resolution of 3 mm. Additionally, the acquisition method allows for correction of T1-enhancing leakage effects by virtue of collecting two echoes, which confound DSC perfusion measurements. The proposed DSC-perfusion method results in high quality perfusion parameter maps across a larger volume than is currently available with current clinical standards, improving diagnostic utility of perfusion MRI methods, which ultimately improves patient care.
X-ray phase contrast imaging (XPCI) is a novel imaging method that utilizes phase information of X-rays in order to produce images. XPCI allows for highly resolved features that traditional X-ray imaging modalities cannot discern. The objective of this experiment was to model initial simulations predicting the output signal of the future compact x-ray free electron laser (CXFEL) XPCI source. The signal was reported in tonal values (“counts”), where MATLAB and MATLAB App Designer were the computing environments used to develop the simulations. The experimental setup’s components included a yttrium aluminum garnet (YAG) scintillating screen, mirror, and Mako G-507C camera with a Sony IMX264 sensor. The main function of the setup was to aim the X-rays at the YAG screen, then measure its scintillation through the photons emitted that hit the camera sensor. The resulting quantity used to assess the signal strength was tonal values (“counts”) per pixel on the sensor. Data for X-ray transmission through water, air, and polyimide was sourced from The Center for X-ray Optics’s simulations website, after which the data was interpolated and referenced in MATLAB. Matrices were an integral part of the saturation calculations; field-of-view (FOV), magnification and photon energies were also necessary. All the calculations were compiled into a graphical user interface (GUI) using App Designer. The code used to build this GUI can be used as a template for later, more complex GUIs and is a great starting point for future work in XPCI research at CXFEL.