Matching Items (4)
Filtering by

Clear all filters

156032-Thumbnail Image.png
Description
Proton beam therapy (PBT) is a state-of-the-art radiotherapy treatment approach that uses focused proton beams for tumor ablation. A key advantage of this approach over conventional photon radiotherapy (XRT) is the unique dose deposition characteristics of protons, resulting in superior healthy tissue sparing. This results in fewer unwanted side effects

Proton beam therapy (PBT) is a state-of-the-art radiotherapy treatment approach that uses focused proton beams for tumor ablation. A key advantage of this approach over conventional photon radiotherapy (XRT) is the unique dose deposition characteristics of protons, resulting in superior healthy tissue sparing. This results in fewer unwanted side effects and improved outcomes for patients. Current available dosimeters are intrinsic, complex and expensive; hence cannot be used to determine the dose delivered to the tumor routinely. Here, we report a hydrogel based plasmonic nanosensor for measurements of clinical doses in ranges between 2-4 GyRBE. In this nanosensor, gold ions, encapsulated in a hydrogel, are reduced to gold nanoparticles following irradiation with proton beams. Formation of gold nanoparticles renders a color change to the originally colorless hydrogel. The intensity of the color can be used to calibrate the hydrogel nanosensor in order to quantify different radiation doses employed during treatment. The potential of this nanosensor for clinical translation was demonstrated using an anthropomorphic phantom mimicking a clinical radiotherapy session. The simplicity of fabrication, detection range in the fractionated radiotherapy regime and ease of detection with translational potential makes this a first-in-kind plasmonic colorimetric nanosensor for applications in clinical proton beam therapy.
ContributorsInamdar, Sahil (Author) / Rege, Kaushal (Thesis advisor) / Anand, Aman (Committee member) / Nannenga, Brent (Committee member) / Arizona State University (Publisher)
Created2017
187367-Thumbnail Image.png
Description
Non-invasive biosensors enable rapid, real-time measurement and quantification of biological processes, such as metabolic state. Currently, the most accurate metabolic sensors are invasive, and significant cost is required, with few exceptions, to achieve similar accuracy using non-invasive methods. This research, conducted within the Biodesign Institute Center for Bioelectronics and Biosensors,

Non-invasive biosensors enable rapid, real-time measurement and quantification of biological processes, such as metabolic state. Currently, the most accurate metabolic sensors are invasive, and significant cost is required, with few exceptions, to achieve similar accuracy using non-invasive methods. This research, conducted within the Biodesign Institute Center for Bioelectronics and Biosensors, leverages the selective reactivity of a chemical sensing solution to develop a sensor which measures acetone in the breath for ketosis and ketoacidosis diagnostics, which is relevant to body weight management and type I diabetes. The sensor displays a gradient of color changes, and the absorbance change is proportional to the acetone concentration in the part- per-million range, making applicable for detection ketosis and ketoacidosis in human breath samples. The colorimetric sensor response can be fitted to a Langmuir-like model for sensor calibration. The sensors best performance comes with turbulent, continuous exposure to the samples, rather than batch sample exposure. With that configuration, these novel sensors offer significant improvements to clinical and at- home measurement of ketosis and ketoacidosis.
ContributorsDenham, Landon (Author) / Forzani, Erica (Thesis advisor) / Wang, Shaopeng (Committee member) / Kulick, Doina (Committee member) / Arizona State University (Publisher)
Created2023
171712-Thumbnail Image.png
Description
Cardiovascular disease is affecting millions of people worldwide and is the leading cause of death in the United States. This disease is closely related to the abnormal creatinine levels in blood. For this reason, there is a need for a low-cost point-of-care device that could measure the creatinine level in

Cardiovascular disease is affecting millions of people worldwide and is the leading cause of death in the United States. This disease is closely related to the abnormal creatinine levels in blood. For this reason, there is a need for a low-cost point-of-care device that could measure the creatinine level in blood with the goal of managing and preventing cardiovascular disease. This project introduces a Molecular Reactive Lateral Flow Assay (MoReLFA) device that is aimed toward creatinine detection based on an optimized chemical reaction of creatinine and alkaline picrate. The device consists of different membranes that accommodate 50 microliters of fluid sample and carry out a colorimetric reaction, in which deposited-colored region is analyzed for Red, Green, and Blue (RGB) components via an image processing software. The color intensity from the RGB outputs was then studied and compared with a gold standard spectrophotometry-based technique. The results show that the MoReLFA sensor could successfully detect creatinine levels in standard solutions. The plot of the sensor color intensity against the absorbance from spectrophotometry shows a good correlation between the two methods (R2 = 0.96). Furthermore, the paper introduces the development of a RGB reader box that is portable and for easy assessment of RGB values. The color intensity from the box shows an increasing trend with increasing creatinine concentrations; and the coefficient of determination of this relationship is 0.85.
ContributorsNguyen, Ngan Anh (Author) / Raupp, Gregory (Thesis advisor) / Forzani, Erica (Thesis advisor) / Mora, Sabrina Jimena (Committee member) / Arizona State University (Publisher)
Created2022
158586-Thumbnail Image.png
Description
Abnormally low or high blood iron levels are common health conditions worldwide and can seriously affect an individual’s overall well-being. A low-cost point-of-care technology that measures blood iron markers with a goal of both preventing and treating iron-related disorders represents a significant advancement in medical care delivery systems. Methods: A

Abnormally low or high blood iron levels are common health conditions worldwide and can seriously affect an individual’s overall well-being. A low-cost point-of-care technology that measures blood iron markers with a goal of both preventing and treating iron-related disorders represents a significant advancement in medical care delivery systems. Methods: A novel assay equipped with an accurate, storable, and robust dry sensor strip, as well as a smartphone mount and (iPhone) app is used to measure total iron in human serum. The sensor strip has a vertical flow design and is based on an optimized chemical reaction. The reaction strips iron ions from blood-transport proteins, reduces Fe(III) to Fe(II), and chelates Fe(II) with ferene, with the change indicated by a blue color on the strip. The smartphone mount is robust and controls the light source of the color reading App, which is calibrated to obtain output iron concentration results. The real serum samples are then used to assess iron concentrations from the new assay and validated through intra-laboratory and inter-laboratory experiments. The intra-laboratory validation uses an optimized iron detection assay with multi-well plate spectrophotometry. The inter-laboratory validation method is performed in a commercial testing facility (LabCorp). Results: The novel assay with the dry sensor strip and smartphone mount, and App is seen to be sensitive to iron detection with a dynamic range of 50 - 300 µg/dL, sensitivity of 0.00049 µg/dL, coefficient of variation (CV) of 10.5%, and an estimated detection limit of ~15 µg/dL These analytical specifications are useful for predicting iron deficiency and overloads. The optimized reference method has a sensitivity of 0.00093 µg/dL and CV of 2.2%. The correlation of serum iron concentrations (N=20) between the optimized reference method and the novel assay renders a slope of 0.95, and a regression coefficient of 0.98, suggesting that the new assay is accurate. Lastly, a spectrophotometric study of the iron detection reaction kinetics is seen to reveal the reaction order for iron and chelating agent. Conclusion: The new assay is able to provide accurate results in intra- and inter- laboratory validations and has promising features of both mobility and low-cost.
ContributorsSerhan, Michael (Author) / Forzani, Erica (Thesis advisor) / Raupp, Gregory (Committee member) / Acharya, Abhinav (Committee member) / Hu, Tony (Committee member) / Smith, Barbara (Committee member) / Arizona State University (Publisher)
Created2020