Matching Items (3)
Filtering by

Clear all filters

151112-Thumbnail Image.png
Description
The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project

The Arizona State University Herbarium began in 1896 when Professor Fredrick Irish collected the first recorded Arizona specimen for what was then called the Tempe Normal School - a Parkinsonia microphylla. Since then, the collection has grown to approximately 400,000 specimens of vascular plants and lichens. The most recent project includes the digitization - both the imaging and databasing - of approximately 55,000 vascular plant specimens from Latin America. To accomplish this efficiently, possibilities in non-traditional methods, including both new and existing technologies, were explored. SALIX (semi-automatic label information extraction) was developed as the central tool to handle automatic parsing, along with BarcodeRenamer (BCR) to automate image file renaming by barcode. These two developments, combined with existing technologies, make up the SALIX Method. The SALIX Method provides a way to digitize herbarium specimens more efficiently than the traditional approach of entering data solely through keystroking. Using digital imaging, optical character recognition, and automatic parsing, I found that the SALIX Method processes data at an average rate that is 30% faster than typing. Data entry speed is dependent on user proficiency, label quality, and to a lesser degree, label length. This method is used to capture full specimen records, including close-up images where applicable. Access to biodiversity data is limited by the time and resources required to digitize, but I have found that it is possible to do so at a rate that is faster than typing. Finally, I experiment with the use of digital field guides in advancing access to biodiversity data, to stimulate public engagement in natural history collections.
ContributorsBarber, Anne Christine (Author) / Landrum, Leslie R. (Thesis advisor) / Wojciechowski, Martin F. (Thesis advisor) / Gilbert, Edward (Committee member) / Lafferty, Daryl (Committee member) / Arizona State University (Publisher)
Created2012
134823-Thumbnail Image.png
Description
Imaging using electric fields could provide a cheaper, safer, and easier alternative to the standard methods used for imaging. The viability of electric field imaging at very low frequencies using D-dot sensors has already been investigated and proven. The new goal is to determine if imaging is viable at high

Imaging using electric fields could provide a cheaper, safer, and easier alternative to the standard methods used for imaging. The viability of electric field imaging at very low frequencies using D-dot sensors has already been investigated and proven. The new goal is to determine if imaging is viable at high frequencies. In order to accomplish this, the operational amplifiers used in the very low frequency imaging test set up must be replaced with ones that have higher bandwidth. The trade-off of using these amplifiers is that they have a typical higher input leakage current on the order of 100 compared to the standard. Using a modified circuit design technique that reduces input leakage current of the operational amplifiers used in the imaging test setup, a printed circuit board with D-dot sensors is fabricated to identify the frequency limitations of electric field imaging. Data is collected at both low and high frequencies as well as low peak voltage. The data is then analyzed to determine the range in intensity of electric field and frequency that this circuit low-leakage design can accurately detect a signal. Data is also collected using another printed circuit board that uses the standard circuit design technique. The data taken from the different boards is compared to identify if the modified circuit design technique allows for higher sensitivity imaging. In conclusion, this research supports that using low-leakage design techniques can allow for signal detection comparable to that of the standard circuit design. The low-leakage design allowed for sensitivity within a factor two to that of the standard design. Although testing at higher frequencies was limited, signal detection for the low-leakage design was reliable up until 97 kHz, but further experimentation is needed to determine the upper frequency limits.
ContributorsLin, Richard (Co-author) / Angell, Tyler (Co-author) / Allee, David (Thesis director) / Chung, Hugh (Committee member) / Electrical Engineering Program (Contributor) / W. P. Carey School of Business (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
157900-Thumbnail Image.png
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are

Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are military surveillance, remote

sensing in space and earth science missions and medical diagnosis. This work focuses

on developing a ROIC unit cell prototype for National Aeronautics and Space Ad

ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These

space applications also demand high sensitivity, longer integration times(large well

capacity), wide operating temperature range, wide input current range and immunity

to radiation events such as Single Event Latchup(SEL).

This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,

to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared

Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range

of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.

The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and

supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per

second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.

The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling

integration times as long as 10ms, to achieve better dynamic range. The DROIC unit

cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.

The proposed DROIC uses layout techniques that make it immune to radiation up to

300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a

wide input current range from 10pA to 1uA and supports detectors operating from

Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019