Matching Items (3)
Filtering by

Clear all filters

156745-Thumbnail Image.png
Description
Many planetary science missions study thermophysical properties of surfaces using infrared spectrometers and infrared cameras. Thermal inertia is a frequently derived thermophysical property that quantifies the ability for heat to exchange through planetary surfaces.

To conceptualize thermal inertia, the diffusion equation analogies are extended using a general effusivity term: the square

Many planetary science missions study thermophysical properties of surfaces using infrared spectrometers and infrared cameras. Thermal inertia is a frequently derived thermophysical property that quantifies the ability for heat to exchange through planetary surfaces.

To conceptualize thermal inertia, the diffusion equation analogies are extended using a general effusivity term: the square root of a product of conductivity and capacity terms. A hypothetical thermal inductance was investigated for diurnal planetary heating. The hyperbolic heat diffusion equation was solved to derive an augmented thermal inertia. The hypothetical thermal inductance was modeled with negligible effect on Mars.

Extending spectral performance of infrared cameras was desired for colder bodies in the outer solar system where peak infrared emission is at longer wavelengths. The far-infrared response of an infrared microbolometer array with a retrofitted diamond window was determined using an OSIRIS-REx—OTES interferometer. An instrument response function of the diamond interferometer-microbolometer system shows extended peak performance from 15 µm out to 20 µm and 40% performance to at least 30 µm. The results are folded into E-THEMIS for the NASA flagship mission: Europa Clipper.

Infrared camera systems are desired for the expanding smallsat community that can inherit risk and relax performance requirements. The Thermal-camera for Exploration, Science, and Imaging Spacecraft (THESIS) was developed for the Prox-1 microsat mission. THESIS, incorporating 2001 Mars Odyssey—THEMIS experience, consists of an infrared camera, a visible camera, and an instrument computer. THESIS was planned to provide images for demonstrating autonomous proximity operations between two spacecraft, verifying deployment of the Planetary Society’s LightSail-B, and conducting remote sensing of Earth. Prox-1—THESIS was selected as the finalist for the competed University Nanosatellite Program-7 and was awarded a launch on the maiden commercial SpaceX Falcon Heavy. THESIS captures 8-12 µm IR images with 100 mm optics and RGB color images with 25 mm optics. The instrument computer was capable of instrument commanding, automatic data processing, image storage, and telemetry recording. The completed THESIS has a mass of 2.04 kg, a combined volume of 3U, and uses 7W of power. THESIS was designed, fabricated, integrated, and tested in ASU’s 100K clean lab.
ContributorsVeto, Michael (Author) / Christensen, Philip C (Thesis advisor) / Bell III, Jim (Committee member) / Clarke, Amanda B (Committee member) / Asphaug, Erik (Committee member) / Sariapli, Srikanth (Committee member) / Ruff, Steven (Committee member) / Arizona State University (Publisher)
Created2018
157327-Thumbnail Image.png
Description
The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length

The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length continuously increases leading to a sharp dose near the end of range. Unlike conventional radiation therapy, protons stop inside the patient, sparing tissue beyond the tumor. Proton therapy should be superior to existing modalities, however, because protons stop inside the patient, there is uncertainty in the range. “Range uncertainty” causes doctors to take a conservative approach in treatment planning, counteracting the advantages offered by proton therapy. Range uncertainty prevents proton therapy from reaching its full potential.

A new method of delivering protons, pencil-beam scanning (PBS), has become the new standard for treatment over the past few years. PBS utilizes magnets to raster scan a thin proton beam across the tumor at discrete locations and using many discrete pulses of typically 10 ms duration each. The depth is controlled by changing the beam energy. The discretization in time of the proton delivery allows for new methods of dose verification, however few devices have been developed which can meet the bandwidth demands of PBS.

In this work, two devices have been developed to perform dose verification and monitoring with an emphasis placed on fast response times. Measurements were performed at the Mayo Clinic. One detector addresses range uncertainty by measuring prompt gamma-rays emitted during treatment. The range detector presented in this work is able to measure the proton range in-vivo to within 1.1 mm at depths up to 11 cm in less than 500 ms and up to 7.5 cm in less than 200 ms. A beam fluence detector presented in this work is able to measure the position and shape of each beam spot. It is hoped that this work may lead to a further maturation of detection techniques in proton therapy, helping the treatment to reach its full potential to improve the outcomes in patients.
ContributorsHolmes, Jason M (Author) / Alarcon, Ricardo (Thesis advisor) / Bues, Martin (Committee member) / Galyaev, Eugene (Committee member) / Chamberlin, Ralph (Committee member) / Arizona State University (Publisher)
Created2019
157900-Thumbnail Image.png
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are

Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag

ing systems. Performance of ROICs affect the quality of images obtained from IR

imaging systems. Contemporary infrared imaging applications demand ROICs that

can support large dynamic range, high frame rate, high output data rate, at low

cost, size and power. Some of these applications are military surveillance, remote

sensing in space and earth science missions and medical diagnosis. This work focuses

on developing a ROIC unit cell prototype for National Aeronautics and Space Ad

ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These

space applications also demand high sensitivity, longer integration times(large well

capacity), wide operating temperature range, wide input current range and immunity

to radiation events such as Single Event Latchup(SEL).

This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,

to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared

Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range

of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.

The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and

supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per

second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.

The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling

integration times as long as 10ms, to achieve better dynamic range. The DROIC unit

cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.

The proposed DROIC uses layout techniques that make it immune to radiation up to

300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a

wide input current range from 10pA to 1uA and supports detectors operating from

Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019