Matching Items (5)
Filtering by

Clear all filters

152200-Thumbnail Image.png
Description
Magnetic Resonance Imaging using spiral trajectories has many advantages in speed, efficiency in data-acquistion and robustness to motion and flow related artifacts. The increase in sampling speed, however, requires high performance of the gradient system. Hardware inaccuracies from system delays and eddy currents can cause spatial and temporal distortions in

Magnetic Resonance Imaging using spiral trajectories has many advantages in speed, efficiency in data-acquistion and robustness to motion and flow related artifacts. The increase in sampling speed, however, requires high performance of the gradient system. Hardware inaccuracies from system delays and eddy currents can cause spatial and temporal distortions in the encoding gradient waveforms. This causes sampling discrepancies between the actual and the ideal k-space trajectory. Reconstruction assuming an ideal trajectory can result in shading and blurring artifacts in spiral images. Current methods to estimate such hardware errors require many modifications to the pulse sequence, phantom measurements or specialized hardware. This work presents a new method to estimate time-varying system delays for spiral-based trajectories. It requires a minor modification of a conventional stack-of-spirals sequence and analyzes data collected on three orthogonal cylinders. The method is fast, robust to off-resonance effects, requires no phantom measurements or specialized hardware and estimate variable system delays for the three gradient channels over the data-sampling period. The initial results are presented for acquired phantom and in-vivo data, which show a substantial reduction in the artifacts and improvement in the image quality.
ContributorsBhavsar, Payal (Author) / Pipe, James G (Thesis advisor) / Frakes, David (Committee member) / Kodibagkar, Vikram (Committee member) / Arizona State University (Publisher)
Created2013
137469-Thumbnail Image.png
Description
Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation

Oxygen delivery is crucial for the development of healthy, functional tissue. Low tissue oxygenation, or hypoxia, is a characteristic that is common in many tumors. Hypoxia contributes to tumor malignancy and can reduce the success of chemotherapy and radiation treatment. There is a current need to noninvasively measure tumor oxygenation or pO2 in patients to determine a personalized treatment method. This project focuses on creating and characterizing nanoemulsions using a pO2 reporter molecule hexamethyldisiloxane (HMDSO) and its longer chain variants as well as assessing their cytotoxicity. We also explored creating multi-modal (MRI/Fluorescence) nanoemulsions.
ContributorsGrucky, Marian Louise (Author) / Kodibagkar, Vikram (Thesis director) / Rege, Kaushal (Committee member) / Stabenfeldt, Sarah (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
155261-Thumbnail Image.png
Description
Dynamic susceptibility contrast MRI (DSC-MRI) is a powerful tool used to quantitatively measure parameters related to blood flow and volume in the brain. The technique is known as a “bolus-tracking” method and relies upon very fast scanning to accurately measure the flow of contrast agent into and out of a

Dynamic susceptibility contrast MRI (DSC-MRI) is a powerful tool used to quantitatively measure parameters related to blood flow and volume in the brain. The technique is known as a “bolus-tracking” method and relies upon very fast scanning to accurately measure the flow of contrast agent into and out of a region of interest. The need for high temporal resolution to measure contrast agent dynamics limits the spatial coverage of perfusion parameter maps which limits the utility of DSC-perfusion studies in pathologies involving the entire brain. Typical clinical DSC-perfusion studies are capable of acquiring 10-15 slices, generally centered on a known lesion or pathology.

The methods developed in this work improve the spatial coverage of whole-brain DSC-MRI by combining a highly efficient 3D spiral k-space trajectory with Generalized Autocalibrating Partial Parallel Acquisition (GRAPPA) parallel imaging without increasing temporal resolution. The proposed method is capable of acquiring 30 slices with a temporal resolution of under 1 second, covering the entire cerebrum with isotropic spatial resolution of 3 mm. Additionally, the acquisition method allows for correction of T1-enhancing leakage effects by virtue of collecting two echoes, which confound DSC perfusion measurements. The proposed DSC-perfusion method results in high quality perfusion parameter maps across a larger volume than is currently available with current clinical standards, improving diagnostic utility of perfusion MRI methods, which ultimately improves patient care.
ContributorsTurley, Dallas C (Author) / Pipe, James G (Thesis advisor) / Kodibagkar, Vikram (Thesis advisor) / Frakes, David (Committee member) / Sadleir, Rosalind (Committee member) / Schmainda, Kathleen (Committee member) / Arizona State University (Publisher)
Created2017
135480-Thumbnail Image.png
Description
Compressed sensing magnetic resonance spectroscopic imaging (MRSI) is a noninvasive and in vivo potential diagnostic technique for cancer imaging. This technique undersamples the distribution of specific cancer biomarkers within an MR image as well as changes in the temporal dimension and subsequently reconstructs the missing data. This technique has been

Compressed sensing magnetic resonance spectroscopic imaging (MRSI) is a noninvasive and in vivo potential diagnostic technique for cancer imaging. This technique undersamples the distribution of specific cancer biomarkers within an MR image as well as changes in the temporal dimension and subsequently reconstructs the missing data. This technique has been shown to retain a high level of fidelity even with an acceleration factor of 5. Currently there exist several different scanner types that each have their separate analytical methods in MATLAB. A graphical user interface (GUI) was created to facilitate a single computing platform for these different scanner types in order to improve the ease and efficiency with which researchers and clinicians interact with this technique. A GUI was successfully created for both prospective and retrospective MRSI data analysis. This GUI retained the original high fidelity of the reconstruction technique and gave the user the ability to load data, load reference images, display intensity maps, display spectra mosaics, generate a mask, display the mask, display kspace and save the corresponding spectra, reconstruction, and mask files. Parallelization of the reconstruction algorithm was explored but implementation was ultimately unsuccessful. Future work could consist of integrating this parallelization method, adding intensity overlay functionality and improving aesthetics.
ContributorsLammers, Luke Michael (Author) / Kodibagkar, Vikram (Thesis director) / Hu, Harry (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
161721-Thumbnail Image.png
Description
This thesis describes the development, characterization, and application of new biomedical technologies developed around the photoacoustic effect. The photoacoustic effect is defined as optical absorption-based generation of ultrasound and provides the foundation for a unique method of imaging and molecular detection. The range of applications of the photoacoustic effect have

This thesis describes the development, characterization, and application of new biomedical technologies developed around the photoacoustic effect. The photoacoustic effect is defined as optical absorption-based generation of ultrasound and provides the foundation for a unique method of imaging and molecular detection. The range of applications of the photoacoustic effect have not yet been fully explored. Photoacoustic endoscopy (PAE) has emerged as a minimally invasive tool for imaging internal organs and tissues. One of the main themes of this dissertation involves the first reported dual-intrauterine photoacoustic and ultrasound deep-tissue imaging endoscope. This device was designed to enable physicians at the point-of-care to better elucidate overall gynecological health, by imaging the lining of the human uterus. Intrauterine photoacoustic endoscopy is made possible due to the small diameter of the endoscope (3mm), which allows for complete, 360-degree organ analysis from within the uterine cavity. In certain biomedical applications, however, further minimization is necessary. Sufficiently small diameter endoscopes may allow for the possibility of applying PAE in new areas. To further miniaturize the diameter of our endoscopes, alternative imaging probe designs were investigated. The proposed PAE architecture utilizes a hollow optical waveguide to allow for concentric guiding of both light and sound. This enables imaging depths of up to several millimeters into animal tissue while maintaining an outer diameter of roughly 1mm. In the final focus of this dissertation, these waveguides are further investigated for use in micropipette electrodes, common in the field of single cell electrophysiology. Pulsed light is coupled with these electrodes providing real-time photoacoustic feedback, useful in navigation towards intended targets. Lastly, fluorescence can be generated and collected at the micropipette aperture by utilizing an intra-electrode tapered optical fiber. This allows for a targeted robotic approach to labeled neurons that is independent of microscopy.
ContributorsMiranda, Christopher (Author) / Smith, Barbara S. (Thesis advisor) / Kodibagkar, Vikram (Committee member) / LaBaer, Joshua (Committee member) / Frakes, David (Committee member) / Barkley, Joel (Committee member) / Arizona State University (Publisher)
Created2021