Current methods for IgG antibody detection include enzyme immunoassays (EIA) such as the commercially available Diamedix Immunosimplicity® Measles IgG test kit and the Diamedix Immunosimplicity® Mumps IgG test kit. EIAs generally provide high sensitivity and strong specificity, however, there is a need for rapid screening of measles and mumps specific immunity in outbreak and resource-limited areas which could be solved by use a point-of-care (POC) platform.
This study aims to optimize a point-of-care device for the multiplexed detection of MeV, MuV, and RuV IgG antibodies in sera and to compare the sensitivity to commercial enzyme immunoassays. The IgG antibody levels to MeV and MuV were measured using EIA test kits for a total of 44 healthy serum samples. Of the samples, 6% were seronegative for MeV-specific IgG antibodies and 75% were seronegative for MuV-specific antibodies, showing low correlation of IgG antibody levels between both viruses.
To improve the sensitivity of the POC device, multiple conjugated fluorescent secondary antibodies were tested with different surface chemistries. Signal detection was measured using the pre-developed four-site slide reader. Preliminary data show that Nile Red microspheres provide robust signal detection and should be the secondary antibody of choice when sera are tested for IgG antibodies using the POC platform in future work.
cause of death in children younger than the age of 5 years. While the introduction of the Measles, Mumps, and Rubella vaccine (MMR) has significantly decreased morbidity and mortality rates worldwide, vaccine coverage is highly variable across global regions. Current diagnostic methods rely on enzyme immunoassays (EIA) to detect IgM or IgG Abs in serum. Commercially available Diamedix Immunosimplicity® Measles IgG test kit has been shown to have 91.1% sensitivity and 93.8% specificity, with a positive predictive value of 88.7% and a negative predictive value of 90.9% on the basis of a PRN titer of 120. There is an increasing need for rapid screening for measles specific immunity in outbreak settings. This study aims to develop a rapid molecular diagnostic assay to detect IgG reactive to three individual measles virus (MeV) proteins.
Measles virus (MeV) genes were subcloned into the pJFT7_nGST vector to generate N- terminal GST fusion proteins. Single MeV cistrons were expressed using in vitro transcription/translation (IVTT) with human cell lysate. Expression of GST-tagged proteins was measured with mouse anti-GST mAb and sheep anti-mouse IgG. Relative light units (RLUs) as luminescence was measured. Antibodies to MeV antigens were measured in 40 serum samples from healthy subjects.
Protein expression of three MeV genes of interest was measured in comparison with vector control and statistical significance was determined using the Student’s t-test (p<0.05). N expressed at the highest level with an average RLU value of 3.01 x 109 (p<0.001) and all proteins were expressed at least 50% greater than vector control (4.56 x 106 RLU). 36/40 serum samples had IgG to N (Ag:GST ratio>1.21), F (Ag:GST ratio>1.92), or H (Ag:GST ratio> 1.23).
These data indicate that the in vitro expression of MeV antigens, N, F, and H, were markedly improved by subcloning into pJFT7_nGST vector to generate N-terminal GST fusion proteins. The expression of single MeV genes N, F and H, are suitable antigens for serologic capture analysis of measles-specific antibodies. These preliminary data can be used to design a more intensive study to explore the possibilities of using these MeV antigens as a diagnostic marker.
Methods: We have designed a multiplexed magnetics programmable bead ELISA (MagProBE) to profile the immune responses of the proteins from 11 high-risk HPV types and 2 low-risk types—106 genes in total. HPV genes were optimized for human expression and either built with PCR or commercially purchased, and cloned into the Gateway-compatible pANT7_cGST vector for in vitro transcription/translation (IVTT) in a MagProBE array. Anti-GST antibody (Ab) labeling was then used to measure gene expression.
Results: 53/106 (50%) HPV genes have been cloned and tested for expression of protein. 91% of HPV proteins expressed at levels above the background control (MFI = 2288), and the mean expression was MFI = 4318. Codon-optimized genes have also shown a 20% higher expression over non-codon optimized genes.
Conclusion: Although this research is ongoing, it suggests that gene optimization may improve IVTT expression of HPV proteins in human HeLa lysate. Once the remaining HPV proteins have been expression confirmed, the cDNA for each gene will be printed onto slides and tested in serologic assays to identify potential Ab biomarkers to CIN3.
The Human Leukocyte Antigen (HLA) is a protein on the surface of cells that is a large component of the adaptive immune response as it helps recognize foreign pathogenic material. We wonder if a set of primers designed for each HLA type could be used to amplify a wide spectrum of HLA to improve sequencing of HLA to improve HLA-typing access. We propose the use of an HLA allele panel to determine the pulldown capacity of the primers followed by MinION sequencing and also offer a multiplexing design for running 96 patients at once. Our results show that primers can capture Class I HLA alleles and typing was successful with an average alignment accuracy of 91.7%. In conclusion this method for HLA capture could be utilized for HLA-typing with material costs of under $3.00 per sample within 3 days.