The purpose of this project is to improve upon the passive ankle foot orthosis originally designed in the ASU’s Robotics and Intelligent Systems Laboratory (RISE Lab). This device utilizes springs positioned parallel to the user’s Achilles tendon which store energy to be released during the push off phase of the user’s gait cycle. Goals of the project are to improve the speed and reliability of the ratchet and pawl mechanism, design the device to fit a wider range of shoe sizes, and reduce the overall mass and size of the device. The resulting system is semi-passive and only utilizes a single solenoid to unlock the ratcheting mechanism when the spring’s potential force is required. The device created also utilizes constant force springs rather than traditional linear springs which allows for a more predictable level of force. A healthy user tested the device on a treadmill and surface electromyography (sEMG) sensors were placed on the user’s plantar flexor muscles to monitor potential reductions in muscular activity resulting from the assistance provided by the AFO device. The data demonstrates the robotic shoe was able to assist during the heel-off stage and reduced activation in the plantar flexor muscles was evident from the EMG data collected. As this is an ongoing research project, this thesis will also recommend possible design upgrades and changes to be made to the device in the future. These upgrades include utilizing a carbon fiber or lightweight plastic frame such as many of the traditional ankle foot-orthosis sold today and introducing a system to regulate the amount of spring force applied as a function of the force required at specific times of the heel off gait phase.
Falls are known to be a common occurrence and a costly one as well, as they are the second leading cause of unintentional deaths and millions of other injuries worldwide. Falls often occur due to an increase in trunk flexion angle, so this experiment aims to reduce the trunk flexion received while stepping over an obstacle. To achieve this a soft actuator was attached to the trunk and pressure was sent as subjects walked and stepped over an obstacle presented on a treadmill. The pressure is meant to stiffen the back which should in theory reduce the trunk flexion angle and lower the chances of falling. In this experiment, two groups were tested: three participants from a control group (healthy young adults) and three participants from an experimental group (healthy elderly adults). Since elderly adults have the highest fall risk due to overall lack of stability, they are the experimental group and the focus for this experiment. The results from the study showed that elderly adults had a beneficial effect with the soft actuator as there was a noticeable difference in trunk flexion when the device was attached. The experiment also supported prior research that stated that trunk flexion was greater in elderly adults than younger adults. Despite the positive results, further studies should be done to prove that the soft devices influence lowering trunk flexion angle as well as to see if the device has any noticeable effect on younger adults.