The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length

The challenge of radiation therapy is to maximize the dose to the tumor while simultaneously minimizing the dose elsewhere. Proton therapy is well suited to this challenge due to the way protons slow down in matter. As the proton slows down, the rate of energy loss per unit path length continuously increases leading to a sharp dose near the end of range. Unlike conventional radiation therapy, protons stop inside the patient, sparing tissue beyond the tumor. Proton therapy should be superior to existing modalities, however, because protons stop inside the patient, there is uncertainty in the range. “Range uncertainty” causes doctors to take a conservative approach in treatment planning, counteracting the advantages offered by proton therapy. Range uncertainty prevents proton therapy from reaching its full potential.

A new method of delivering protons, pencil-beam scanning (PBS), has become the new standard for treatment over the past few years. PBS utilizes magnets to raster scan a thin proton beam across the tumor at discrete locations and using many discrete pulses of typically 10 ms duration each. The depth is controlled by changing the beam energy. The discretization in time of the proton delivery allows for new methods of dose verification, however few devices have been developed which can meet the bandwidth demands of PBS.

In this work, two devices have been developed to perform dose verification and monitoring with an emphasis placed on fast response times. Measurements were performed at the Mayo Clinic. One detector addresses range uncertainty by measuring prompt gamma-rays emitted during treatment. The range detector presented in this work is able to measure the proton range in-vivo to within 1.1 mm at depths up to 11 cm in less than 500 ms and up to 7.5 cm in less than 200 ms. A beam fluence detector presented in this work is able to measure the position and shape of each beam spot. It is hoped that this work may lead to a further maturation of detection techniques in proton therapy, helping the treatment to reach its full potential to improve the outcomes in patients.
ContributorsHolmes, Jason M (Author) / Alarcon, Ricardo (Thesis advisor) / Bues, Martin (Committee member) / Galyaev, Eugene (Committee member) / Chamberlin, Ralph (Committee member) / Arizona State University (Publisher)
Created2019
148451-Thumbnail Image.png
Description

Rotary drums are tools used extensively in various prominent industries for their utility in heating and transporting particulate products. These processes are often inefficient and studies on heat transfer in rotary drums will reduce energy consumption as operating parameters are optimized. Research on this subject has been ongoing at ASU;

Rotary drums are tools used extensively in various prominent industries for their utility in heating and transporting particulate products. These processes are often inefficient and studies on heat transfer in rotary drums will reduce energy consumption as operating parameters are optimized. Research on this subject has been ongoing at ASU; however, the design of the rotary drum used in these studies is restrictive and experiments using radiation heat transfer have not been possible.<br/><br/>This study focuses on recounting the steps taken to upgrade the rotary drum setup and detailing the recommended procedure for experimental tests using radiant heat transfer upon completed construction of the new setup. To develop an improved rotary drum setup, flaws in the original design were analyzed and resolved. This process resulted in a redesigned drum heating system, an altered thinner drum, and a larger drum box. The recommended procedure for radiant heat transfer tests is focused on determining how particle size, drum fill level, and drum rotation rate impact the radiant heat transfer rate.

ContributorsMiller, Erik R (Author) / Emady, Heather (Thesis director) / Muhich, Christopher (Committee member) / Chemical Engineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
Description

Rotary drums are used to manufacture pharmaceuticals, cement, food, and other particulate products because of their high heat and mass transfer rates. These processes are governed by particle parameters, such as particle size, particle distribution, and shape, and operating parameters, such as rotation rate and fill level. Enormous energy savings

Rotary drums are used to manufacture pharmaceuticals, cement, food, and other particulate products because of their high heat and mass transfer rates. These processes are governed by particle parameters, such as particle size, particle distribution, and shape, and operating parameters, such as rotation rate and fill level. Enormous energy savings are possible with further research in rotary drums due to potential increases in operating efficiency. This study investigates the drum rotation rate on particle bed temperature at temperatures above 500 °C to see the role that radiation heat transfer plays in this process. 2 mm silica beads and a stainless steel rotary drum were used at a fill level of 25% with rotation rates from 2-10 rpm. A new setup and procedure were developed using heating coils and an IR camera to reach high temperatures. The inner drum wall temperature exceeded the outer drum wall temperature because the steel transmitted more heat into the drum at higher temperatures. Although it was unclear whether the heat transfer rate was affected by the increasing rotation rate, the highest final average particle temperature was obtained at 5 rpm. The particle bed temperature distribution narrowed as the rotation rate increased because, at higher rotation rates, more particles are in contact with the drum wall than at lower rotation rates.

ContributorsTronstad, Joel (Author) / Emady, Heather (Thesis director) / Holloway, Julianne (Committee member) / Barrett, The Honors College (Contributor) / Chemical Engineering Program (Contributor) / Dean, W.P. Carey School of Business (Contributor)
Created2023-05