Filtering by
- All Subjects: Biomaterials
- All Subjects: Imaging
- Creators: Stabenfeldt, Sarah
- Status: Published
Polymeric nanoparticles (NP) consisting of Poly Lactic-co-lactic acid - methyl polyethylene glycol (PLLA-mPEG) or Poly Lactic-co-Glycolic Acid (PLGA) are an emerging field of study for therapeutic and diagnostic applications. NPs have a variety of tunable physical characteristics like size, morphology, and surface topography. They can be loaded with therapeutic and/or diagnostic agents, either on the surface or within the core. NP size is an important characteristic as it directly impacts clearance and where the particles can travel and bind in the body. To that end, the typical target size for NPs is 30-200 nm for the majority of applications. Fabricating NPs using the typical techniques such as drop emulsion, microfluidics, or traditional nanoprecipitation can be expensive and may not yield the appropriate particle size. Therefore, a need has emerged for low-cost fabrication methods that allow customization of NP physical characteristics with high reproducibility. In this study we manufactured a low-cost (<$210), open-source syringe pump that can be used in nanoprecipitation. A design of experiments was utilized to find the relationship between the independent variables: polymer concentration (mg/mL), agitation rate of aqueous solution (rpm), and injection rate of the polymer solution (mL/min) and the dependent variables: size (nm), zeta potential, and polydispersity index (PDI). The quarter factorial design consisted of 4 experiments, each of which was manufactured in batches of three. Each sample of each batch was measured three times via dynamic light scattering. The particles were made with PLLA-mPEG dissolved in a 50% dichloromethane and 50% acetone solution. The polymer solution was dispensed into the aqueous solution containing 0.3% polyvinyl alcohol (PVA). Data suggests that none of the factors had a statistically significant effect on NP size. However, all interactions and relationships showed that there was a negative correlation between the above defined input parameters and the NP size. The NP sizes ranged from 276.144 ± 14.710 nm at the largest to 185.611 ± 15.634 nm at the smallest. In conclusion, the low-cost syringe pump nanoprecipitation method can achieve small sizes like the ones reported with drop emulsion or microfluidics. While there are trends suggesting predictable tuning of physical characteristics, significant control over the customization has not yet been achieved.
ing systems. Performance of ROICs affect the quality of images obtained from IR
imaging systems. Contemporary infrared imaging applications demand ROICs that
can support large dynamic range, high frame rate, high output data rate, at low
cost, size and power. Some of these applications are military surveillance, remote
sensing in space and earth science missions and medical diagnosis. This work focuses
on developing a ROIC unit cell prototype for National Aeronautics and Space Ad
ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These
space applications also demand high sensitivity, longer integration times(large well
capacity), wide operating temperature range, wide input current range and immunity
to radiation events such as Single Event Latchup(SEL).
This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,
to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared
Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range
of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.
The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and
supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per
second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.
The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling
integration times as long as 10ms, to achieve better dynamic range. The DROIC unit
cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.
The proposed DROIC uses layout techniques that make it immune to radiation up to
300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a
wide input current range from 10pA to 1uA and supports detectors operating from
Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.